• Title/Summary/Keyword: diameter of thickness ratio

Search Result 359, Processing Time 0.031 seconds

Lung Biopsy in Congenital Heart Disease (선천성 심장 질환 환자의 폐 생검)

  • 김광호
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 1981
  • Twenty eight patients with conpnital heart disuse underwent lung biopsy to assets pulmonary obstructive vascular disease at cardiac surpry. Thirteen patients had patent ductus arteriosus, 10, ventricular septal defects and S, atrial septal defects. The aaes were between 2 and 30 years. In patients with patent ductus arteriosus lung biopsy was performed from the IIngular Hlment. The anterior seament of the right upper lobe was blopsled in cases with ventricular septal defect and atrial septal defect. Grading of pulmonary obstructive vascular disease could not be assessed In 9 cases. In 2 cases poor quality of the slides made us impossible to evaluate and In 7 cases there were no suitable small muscular arteries to evaluate in the slides of lung tissue especially taken from the IIngular seament. Nineteen cases were evaluated pulmonary obstructive vascular disease. Among them 17 cases had Heath-Edwards changes of grade 1 and 2 patients had that of grade 3. The thickness of media was measured. It was expressed as percentage of medial thickness to outer diameter of artery. The medial thickness was correlated proportionally with elevation of pulmonary arterial pressure and pulmonary vascular resistance to systemic vascular resistance ratio. There were no complications related to the procedure of lung biopsy.

  • PDF

Bending and Shear Capacity of Reinforced Concrete Protective Wall (휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구)

  • Young Beom Kwon;Jong Yil Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

Preparation of α-Al2O3 Platelets from Aluminum Hydroxides Gel (Aluminium Hydroxides Gel을 이용한 α-Al2O3 판상체의 제조)

  • 박병기;이정민;서동수;임광수
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.610-617
    • /
    • 2004
  • For preparation $\alpha$-Al$_2$O$_3$ platelets having 20 $\mu$m in average diameter and 0.2∼0.3 $\mu$m in thickness, we have prepared aluminum hydroxides gel by using aluminum sulfate and sodium sulfate as starting materials. In this study, we investigated the effect of the amount of sodium phosphate on particle size, morphology and thickness of $\alpha$-Al$_2$O$_3$ platelets. When sodium phosphate was not added to aluminum hydroxides gel, most of $\alpha$-Al$_2$O$_3$ platelets had hexagonal shape but the thickness was over 1.0 $\mu$m, and this sample was not adequate for pearlescent pigment. On the other hand, introduction of sodium phosphate caused an increase of aspect ratio (particle diameter/thickness) with a decrease in $\alpha$-Al$_2$O$_3$ platelet thickness.

Effect of Thickness Eccentricity on Plastic Collapse of Subsea Pipeline under External Pressure (외압하에서 해저배관의 소성붕괴에 대한 두께 불균일 효과)

  • Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.14-19
    • /
    • 2011
  • The objective of this study was to investigate the effect of the thickness eccentricity on the collapse pressure of a subsea pipeline subjected to external pressure. The collapse behavior of the subsea pipeline containing initial imperfection was evaluated using elastic-plastic finite element (FE) analyses. API 5L X65 and API 5L X80 Pipelines with the thickness eccentricity values between 4~16% were adopted to investigate the plastic collapse under hydrostatic pressure. A parametric study was shown that the plastic collapse pressure decreased when either the thickness eccentricity or the ratio of diameter to thickness increased.

Investigation of Shear Design Expressions of Large-Diameter Concrete-Filled Steel Tubes(CFT) (대구경 콘크리트 충전형 합성기둥의 전단 설계식 분석)

  • Jung, Eun Bi;Yeom, Hee Jin;Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.399-410
    • /
    • 2015
  • Concrete filled steel tube(CFT) has outstanding deformation capacity and strength in comparison with reinforced concrete or steel tube. CFT drilled shaft, which is developed large shear force due to seismic load and soil liquefaction, is designed as large diameter. However, shear design equations of the current standards do not consider bond stress of CFT and it results in extremely conservative design. Currently, previous studies for improving shear equations scarcely exist and are impossible applied to large CFT drilled shafts since these studies focus on only small scale experimental research. In this study, eventually to propose improving shear equation of large diameter CFT, it is preliminary research to compare and investigate the previous studies and current standards.

Effect of plate properties on shear strength of bolt group in single plate connection

  • Ashakul, Aphinat;Khampa, Kriangkrai
    • Steel and Composite Structures
    • /
    • v.16 no.6
    • /
    • pp.611-637
    • /
    • 2014
  • A single plate shear connection, or shear tab, is a very popular shear connection due to its merit in ease of construction and material economy. However, problems in understanding the connection behavior, both in terms of strength and ductility, have been well-documented. Suggestions or design model for single plate connections in AISC Design Manual have been altered several times, with the latest edition settling down to giving designers pre-calculated design strength tables if the connection details agree with given configurations. Results from many full-scale tests and finite element models in the past suggest that shear strength of a bolt group in single plate shear connections might be affected by yield strength of plate material; therefore, this research was aimed to investigate and clarify effects of plate yield strength and thickness on shear strength of the bolt group in the connections, including the validity of using a plate thickness/bolt diameter ratio ($t_p/d_b$) in design, by using finite element models. More than 20 models have been created by using ABAQUS program with 19.0- and 22.2-mm A325N bolts and A36 and Gr.50 plates with various thicknesses. Results demonstrated that increase of plate thickness or plate yield strength, with the $t_p/d_b$ ratio remained intact, could significantly reduce shear strength of the bolt group in the connection as much as 15 percent. Results also confirmed that the $t_p/d_b$ ratio is a valid indicator to be used for guaranteeing strength sufficiency. Because the actual ratio recommended by AISC Design Manual is $t_p/d_b$ + 1.6 (mm) for connections with a number of bolts less than six and plate yield strength in construction is normally higher than the nominal value used in design, it is proposed that shear strength of a bolt group in single plate connections with a number of bolts equal or greater than seven be reduced by 15 percent and the $t_p/d_b$ ratio be limited to 0.500.

Electrical Characteristics of Disk-type Piezoelectric Transformer Poled with the Same Direction (동일 방향으로 분극된 디스크형 압전변압기의 전기적 특성)

  • 이종필;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.688-692
    • /
    • 2003
  • For high voltage operation, a new type of piezoelectric transformer using radial vibration of disk, poled with the same direction was proposed. The piezoelectric ceramics was composed to PZT-PMN-PSN. The diameter and thickness of a disk type piezoelectric transformer were 45[mm]and 4[mm], respectively The surface ratio of driving electrode and generating electrode of the piezoelectric transformer was 2 : 1. The resonance characteristics of input admittance, step-up voltage ratio and power transmission efficiency of the piezoelectric transformer were measured by varying the load resistance(0.1∼70[kΩ]). As a result, both resonance frequency and step-up voltage ratio increased with increasing load resistance. The step-up voltage ratio was reached more than 60 times under no load resistance. The maximum efficiency of 97% at load resistance of 2kΩ was obtained.

Ducti1ity, Evaluation of Circular Reinforced Concrete Piers with an Internal Steel Tube (강관 내무보강 중공교각의 연성도 평가)

  • 강영종;최진유;김도연;한택희
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.241-248
    • /
    • 2001
  • The ductility of circular hollow reinforced concrete columns with one layer of longitudinal and spiral reinforcement placed near the outside face of the section and the steel tube placed on the inside face of the section is investigated. Such hollow sections are confined through the wall thickness since the steel tube is placed. The results of analytical moment-curvature analyses for such hollow sections are compared with those for the circular section with the sane diameter. In this study, moment-curvature analyses are conducted with Mandel's confined concrete stress-strain relationship in which the effect of confinement is to increase the compression strength and ultimate strain of concrete. The moment-curvature analyses confirmed that the ductility is primarily influenced on the ultimate strain. The variables influenced on the ultimate strain is the ratio and yield strength of confining reinforcement and the compression strength for confined concrete. From this ultimate strain - the transverse reinforcement ratio relationship, the transverse reinforcement ratio for circular hollow reinforced columns with confinement is proposed. The proposed transverse reinforcement ratio is confirmed by experimental results.

  • PDF

Seismic performance and damage evaluation of concrete-encased CFST composite columns subjected to different loading systems

  • Xiaojun Ke;Haibin Wei;Linjie Yang;Jin An
    • Steel and Composite Structures
    • /
    • v.47 no.1
    • /
    • pp.121-134
    • /
    • 2023
  • This paper tested 11 concrete-encased concrete-filled steel tube (CFST) composite columns and one reinforced concrete column under combined axial compression and lateral loads. The primary parameters, including the loading system, axial compression ratio, volume stirrup ratio, diameter-to-thickness ratio of the steel tube, and stirrup form, were varied. The influence of the parameters on the failure mode, strength, ductility, energy dissipation, strength degradation, and damage evolution of the composite columns were revealed. Moreover, a two-parameter nonlinear seismic damage model for composite columns was established, which can reflect the degree and development process of the seismic damage. In addition, the relationships among the inter-story drift ratio, damage index and seismic performance level of composite columns were established to provide a theoretical basis for seismic performance design and damage assessments.

Seismic rehabilitation of substandard RC columns with partially deteriorated concrete using CFRP composites

  • Hou, Dongxu;Wu, Zhimin;Zheng, Jianjun;Cui, Yao
    • Computers and Concrete
    • /
    • v.15 no.1
    • /
    • pp.1-20
    • /
    • 2015
  • Many existing reinforced concrete (RC) columns in structures tend to become substandard RC ones due to updated standards or environmental changes. These substandard columns may alter the behaviors of the whole structure and therefore are in urgent need of seismic retrofitting. Owing to their superior advantages, carbon fiber reinforced polymer (CFRP) composites are widely used to retrofit RC columns. The applications mainly focus on various substandard RC columns, but few deals with substandard columns with deteriorated concrete, especially damaged by earthquake. The purpose of this paper is to investigate the seismic behaviors of CFRP reinforced partially deteriorated RC columns and to evaluate the effect of CFRP sheets on them. Six flexure-dominant columns were tested under a constant axial load and transverse cyclic displacements. It is found that the seismic behaviors of partially deteriorated columns can be recovered by wrapping CFRP sheets on them. Numerical analysis is then conducted using finite element methods and verified with experimental results. The effects of the axial load ratio, the ratio of the thickness of CFRP sheet to the column diameter, and the slenderness ratio on the seismic behaviors of CFRP reinforced RC columns are evaluated. Finally, a method is proposed to determine the required thickness of CFRP sheet.