• Title/Summary/Keyword: diagnostic tests

Search Result 813, Processing Time 0.022 seconds

On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성)

  • Kim, Hee-Dong;Ju, Young-Ho;Yoon, Dea-Hen
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics (초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계)

  • Lim, Do-Hyung;Kim, Eun-Geun;Lee, Gyoun-Jung;Park, Won-Pil;Kim, Han-Sung;Shin, Tae-Min;Choi, Seo-Hyung;Lee, Yong-Heum
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

Prevalence-based Interpretation of Predictive Values of Diagnostic Tests: An Example for Detection of Canine Heartworm Infection (진단키트 검사결과에 대한 유병율 위주 해석: 개 심장사상충의 예)

  • Park, Choi-Kyu;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.130-133
    • /
    • 2009
  • The use of screening tests as part of a diagnostic work-up is common in domestic canine practice, but understanding of the diagnostic test characteristics and factors affecting diagnostic accuracy is not clear among clinicians. This article was aimed to provide clinicians with a better understanding on the selection of test kits and with a proper interpretation of test results using an example from heartworm(Dirofilaria immitis) studies. From the literatures, diagnostic accuracy varied depending on the kits: percent average sensitivity and specificity of ELISA antigen-detecting kits were DiroChek(Synbiotics, USA) 78.1 and 95.2, SNAP(IDEXX, USA) 66.3 and 98.1, and Solo Step(Heska, Switzerland) 69.5 and 97.5, respectively, while the values for three hematological methods(Modified Knott's, direct smear and capillary tube) ranged from 38.4 to 81.8% and from 96.9 to 100%, respectively. Furthermore, it was also reported that the prevalence of heartworm disease in domestic dog populations varied depending on the regions studied: 2.5-22.8% for microfilarial test and 2.2-66.3% by ELISA. The values of predictive values for positive(PPV) and negative(NPV) provide useful information to clinicians on the probability of heartworm infection, but the PPV and NPV are greatly dependent on the heartworm prevalence. This suggests that PPV or NPV values of a test should be interpreted carefully in different clinical settings. Practical methods on the interpretation taking into account heartworm prevalence were discussed.

New Techniques for the Detection of the Malignant Cells in Urine Cytology (요 세포검사의 최근 검사기법)

  • Gong, Gyung-Yub
    • The Korean Journal of Cytopathology
    • /
    • v.17 no.1
    • /
    • pp.18-26
    • /
    • 2006
  • Transitional cell carcinoma of the urinary bladder is common in the genitourinary tract. The gold standard for the diagnosis of bladder cancer has been cystoscopy, along with urine cytology. Cystoscopy is an invasive and relatively expensive technique. By comparison, urine cytology is easy to perform and specific for a diagnosis of bladder cancer, although less sensitive, especially in low-grade tumors. For this reason, there has been a need for superior noninvasive technology to increase our confidence in being able to detect bladder cancer. There are many reports of the various urinary tests that are available to facilitate the diagnosis. In this article, I reviewed the literature on urinary markers and tests that may be clinically useful, including fluorescence in situ hybridization, uCyt+/Immunocyte, the $BTA^{(R)}$ test, the NMP 22TM, the $FDP^{(R)}$ test, the telomerase activity test, the HA and HAse tests, and flow cytometry. Most of these tests have a higher sensitivity and specificity than cytology. However, urine cytology has the highest specificity, especially in individuals with a high-grade tumor. We conclude that no urinary markers or tests can replace the role of cystoscopy along with cytology in the diagnosis of transitional cell carcinoma of the bladder. However, some markers could be used adjunctively to increase the diagnostic accuracy during screening or during the postoperative follow-up examination of patients with bladder cancer.

Study on the K-scale reflecting the confidence of survey responses (설문 응답에 대한 신뢰도를 반영한 K-척도에 관한 연구)

  • Park, Hye Jung;Pi, Su Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.1
    • /
    • pp.41-51
    • /
    • 2013
  • In the Information age, internet addiction has been a big issue in a modern society. The adverse effects of the internet addiction have been increasing at an exponential speed. Along with a great variety of internet-connected device supplies, K-scale diagnostic criteria have been used for the internet addiction self-diagnose tests in the high-speed wireless Internet service, netbooks, and smart phones, etc. The K-scale diagnostic criteria needed to be changed to meet the changing times, and the diagnostic criteria of K-scale was changed in March, 2012. In this paper, we analyze the internet addiction and K-scale features on the actual condition of Gyeongbuk collegiate areas using the revised K-scale diagnostic criteria in 2012. The diagnostic method on internet addiction is measured by the respondents' subjective estimation. Willful error of the respondents can be occurred to hide their truth. In this paper, we add the survey response to the trusted reliability values to reduce response errors on the K-scale on the K-scale, and enhance the reliability of the analysis.

Detection of antibodies and antigens of Aujeszky's disease virus using dot-immunoassay (Dot-immunoassay를 이용한 Aujeszky's disease virus항원 및 항체 검출)

  • Jun, Moo-hyung;Cho, Young-sung;Chang, Kyung-soo
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.529-536
    • /
    • 1994
  • To establish more specific and simple diagnostic methods for detection of the antibodies and antigens of Aujeszky's disease virus(ADV), we designed indirect dot-immunoassay(IDI) and double sandwich dotimmunoassay(DSDI) using the solid phases of nitrocellolose paper and polystyrene plate. The diagnostic efficacy of these methods was investigated. As the sensitivity of IDI was tested by various virus concentration, the specimens with the virus titer above $10^{4.0}TCID_{50}/0.2ml$ showed positive reaction, but that below $10^{1.0}TCID_{50}/ml$ revealed negative. Tonsil emulsion at the virus titer of $10^{4.5}TCID_{50}/0.2ml$ showed the highest sensitivity as diluted by 1/100. In detection of ADV antigens from the various tissues of the rats and pigs infected with ADV, IDI using monoclonal antibody showed the higher specificity as compared with IDI using polyclonal antibody and virus isolation method. The efficacy of the DSDI for detection of ADV antibody was compared with other tests. The sensitivity of DSDI was higher than virus neutralization(VN) and agar gel immunodiffusion test(AGID). Meanwhile, specificity of DSDI was lower than AGID, but similar to IDEA. In comparison with VN test, DSDI showed 96.9% agreement to VN test that is the highest of three tests. In general, application of polyclonal antibody in both tests caused the higher sensitivity but the lower specificty.

  • PDF

Diagnostic Accuracy of Physical Examinations in Impingement Syndrome and Rotator Cuff Tear (충돌 증후군과 회전근 개 파열을 위한 이학적 검사들의 진단적 가치에 대한 분석)

  • Lee Young Soo;Kim Jin Yong;Cho Duck Yun;Kim Young Ho;Kim Se Hyen
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.2
    • /
    • pp.186-190
    • /
    • 2001
  • Purpose: The aim of this study was to investigate the diagnostic accuracy of Neer, Hawkins provocative tests and supraspinatus manual muscle test for the assessment of impingement syndrome, partial tear and small complete tear of De rotator cuff. Materials and Methods: Seventy-one female and 115 male patients were included in the study. Patients were divided into four groups of no impingement, impingement without tear, partial tear and small complete tear of the rotator cuff, which were confirmed by sonogram, magnetic resonance imaging and surgery. Neer and Hawkins provocative tests and supraspinatus manual muscle test were performed respectively. SAS 6.12 version was used in statistical analysis. Results: We found that Neer test had 94% sensitivity, 54% specificity for impingement without tear and 89% sensitivity, 78% specificity for partial tear and 96% sensitivity, 23% specificity for small tear. Hawkins test revealed 95% sensitivity, 54% specificity for impingement without tear and 93% sensitivity, 78% specificity for partial tear and 100% sensitivity, 23% specificity for small tear. Supraspinatus manual muscle test revealed 27% sensitivity, 94% specificity for impingement without tear and 29% sensitivity, 82% specificity for partial tear and 48% sensitivity, 82% specificity for small tear. Conclusion: Neer and Hawkins tests have high sensitivity, low specificity for impingement syndrome, partial and small tear. Supraspinatus manual muscle test had low sensitivity and high specificity. However this test was not effective to differentiate the partial and small rotator cuff tear. We thought that more effective provocative test should be designed to detect the partial and small rotator cuff tear.

  • PDF

Relationship Between Characteristics of Five Woons in Asian Woman and Physical Tests and Symptoms based on Asian Medicine (아시아 여성의 오운체질(五運體質)별 검사특성 및 증상과의 관계 - 한국과 일본에서 태어난 미국에 거주하는 한국, 일본 여성을 위주로)

  • Jin, Seng-Hee;Choi, Kyung-Mee;Kim, Tae-Hee
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.1
    • /
    • pp.44-56
    • /
    • 2010
  • Objective : To characterize Five Woons of Asian women who live at Los Angeles area in U.S.A Methods : A set of physical tests and diagnostic questions were given to 242 Asian female subjects who were treated for their symptoms at a clinic of Asian medicine near Los Angeles in USA. The participants were given their constitutions, one of the Five Woons based on their birthdays. The physical tests included a body composition via Inbody 4.0 and an autonomic bioelectric response record via ABR2000. The oneway analysis of variance was applied to compare the means of the Five Woons and the physical test results. The Cross tabulation analysis was also applied to look for the effectiveness of Five Woons on the symptoms. Results : 1. In the body composition items, the LSD(least significant difference) showed that there were significant differences between the Soil Woon and the other Four Woons which are Water, Metal, Fire and Wood Woons in weight, fat, body fat %, BMI (p<0.2). 2. Based on the LSD, significant differences were observed among the Five Woons in R5, R6 and R7(p<0.2). 3. The cross tabulation analysis showed the significant effectiveness of the Five Woons on the five symptoms including dizziness, hot and cold, lower body edema, fatigue and to take a medication for high blood pressure out of 24 diagnostic questions (p<0.2). Conclusions : Further clinical research is necessary to develop a more delicate questionnaire and look for ways of characterizing the Five Woons. The diagnosis and corresponding treatment based on the Five Woons should be further studied in view of the Oriental medicine.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

A Preliminary Study on Diagnostic Process for Premarital Preparation by Using a Delphi Method : With Purpose of Developing Tools (델파이조사를 이용한 결혼준비진단에 관한 기초연구)

  • 김혜선;박희성
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.7
    • /
    • pp.125-144
    • /
    • 2001
  • The purpose of this study is to make a preliminary investigation about the diagnostic process for marital preparation against future divorce which will be necessary for developing tools for the process. Delphi tests have been twice held among 23 professionals regarding the concept of marital diagnosis and the areas of marital preparation to be estimated including definitions of the marital preparation for marriage and the status in which marriage has been prepared, and the categorization of the preparation The result of the study is as follows : Firstly, the concept of marital preparation is comprehensive, for it does include various kinds of preparation necessary for adjustment to marital life except the preparation for wedding ceremony. Secondly, the status in which marriage has been prepared can be divided into individual preparation, a couple's relational preparation, and preparation for marital life. Thirdly, premarital preparation education or counselling will be provided for young persons who are not in status of marital preparation. The areas of marital preparation to be estimated are maturity, independence from parents, and good health in terms of individual preparation, and the depth of love, understanding each other, similarity, harmonization, supplementation, capacity of communication, self-control, and all that sort of thing in terms of relational preparation, sex, views about marriage, information about marital life, role division, giving birth to child and rearing, financial management, and understanding both families of husband and wife.

  • PDF