• Title/Summary/Keyword: diagnostic sensitivity

Search Result 1,256, Processing Time 0.03 seconds

Factor analysis using S-detect Method in Breast Ultrasound (유방 초음파 검사 시 S-detect 방법을 활용한 인자 분석)

  • Chun, Hye Ri;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • This study aimed to investigate the performance of the S-detect method in breast ultrasonography and to determine how to reduce unnecessary biopsy by comparing the results of the S-detect method and biopsy. Thirty patients who had undergone breast ultrasonography between August and October 2018 and were scheduled to undergo biopsy because of the presence of breast nodules were retrospectively analyzed. The McNemar test was performed to determine whether detection of a malignant breast mass significantly differed between the S-detect method and biopsy. The following results were obtained from the analysis of the S-detect method: sensitivity, 90.9%; specificity, 84.21%; validity, 86.66%; positive predictive value, 76.92%; and negative predictive value, 94.11%. Analysis of the degree of agreement between the S-detect method and biopsy revealed a kappa value as high as 0.724 (p < 0.05), exhibiting good agreement between the two methods. The S-detect method in breast ultrasonography is diagnostically valuable in terms of distinguishing between malignant and benign breast masses, and if used properly before breast biopsy, unnecessary biopsy can be reduced.

Comparison of Sizes of Anatomical Structures according to Scan Position Changes in Patients with Interstitial Lung Disease Using High-Resolution Thoracic CT (고해상도 흉부 전산화단층촬영을 이용한 간질성 폐질환을 가진 환자의 자세에 따른 해부학적 구조물 크기 비교)

  • Lee, Jae-min;Park, Je-heon;Kim, Ju-seong;Lim, Cheong-Hwan;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.91-100
    • /
    • 2021
  • High-Resolution thoracic CT (HRCT) is a scanning protocol in which thin slice thickness and sharpness algorithm are utilized to enhance image resolution for diagnosis and assessment of interstitial lung disease (ILD). This examination is sometimes performed in both supine and prone position to improve sensitivity to early changes of these conditions. Anatomical structures (the size of lung field and heart and descending aorta) of 150 patients who underwent HRCT were retrospectively compared. HRCT had been conducted in two positions (supine and prone). Data were divided into five groups according to patient body weights (from 40 to more than 80kg, 10kg intervals, 60 patients/each group). Quantitative analysis was utilized in Image J program. In the supine position defined as the control group, the average values of lung fields and heart size and aorta were compared with the prone position defined as the experimental group. The size of the lungs was found to be higher in the supine position, and it was confirmed that there was a statistically significant difference in patients over 70 kg (p<0.05). In addition, both sizes of the heart and descending aorta were larger in prone position, but in the case of the heart, there was no correlation with the presence or absence of ILD disease (p>0.05). Also, the area of prone in the descending aorta was higher than supine position, but there was no statistically significant difference between supine and prone position (p>0.05). In conclusion, when the severity of ILD disease was severe, there was no statistically significant difference in the area difference between supine and prone position, so it is considered that it will be helpful in diagnostic decision.

Elastic Wave Propagation in Nuclear Power Plant Containment Building Walls Considering Liner Plate and Concrete Cavity (라이너 플레이트 및 콘크리트 공동을 고려한 원전 격납건물 벽체의 탄성파 전파 해석)

  • Kim, Eunyoung;Kim, Boyoung;Kang, Jun Won;Lee, Hongpyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.3
    • /
    • pp.167-174
    • /
    • 2021
  • Recent investigation into the integrity of nuclear containment buildings has highlighted the importance of developing an elaborate diagnostic method to evaluate the distribution and size of cavities inside concrete walls. As part of developing such a method, this paper presents a finite element approach to modeling elastic waves propagating in the containment building walls of a nuclear power plant. We introduce a perfectly matched layer (PML) wave-absorbing boundary to limit the large-scale nuclear containment wall to the region of interest. The formulation results in a semi-discrete form with symmetric damping and stiffness matrices. The transient elastic wave equations for a mixed unsplit-field PML were solved for displacement and stresses in the time domain. Numerical results show that the sensitivity of displacement, velocity, acceleration, and stresses is large depending on the size and location of the cavity. The dynamic response of the wall slightly differs depending on the existence of the containment liner plate. The results of this study can be applied to a full-waveform inversion approach for characterizing cavities inside a containment wall.

Performance comparison and evaluation of interferon-gamma assay kit for bovine tuberculosis diagnosis (소 결핵 진단을 위한 인터페론감마 검사 키트의 성능 비교 평가)

  • Hong, Leegon;Choi, Woojae;Ro, Younghye;Ahn, Sunmin;Kim, Eunkyung;Choe, Eunhee;Kim, Danil
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.4
    • /
    • pp.201-209
    • /
    • 2020
  • In Korea, bovine tuberculosis (bTB) is a representative zoonotic disease that causes considerable economic loss. In determining the positive bTB, the ELISA method for examining the amount of interferon-gamma (IFN-γ) is included in Korea's diagnostic standard method. Recently, commercially available BIONOTE TB-Feron ELISA Plus (TB-Feron Plus) that detects IFN-γ has been introduced. However, since the scientific basis for the performance is limited, we evaluated performance by comparing it with the results of another IFN-γ ELISA assay kit (BOVIGAM®) certified by Office International des Epizooties. In our research, 42 positive blood samples preliminarily tested with a tuberculin skin test and/or BOVIGAM® and 54 negative blood samples collected from three bTB free farms were subjected to IFN-γ assay using the TB-Feron Plus and the BOVIGAM®, respectively. The result shows that the sensitivity, specificity and accuracy were 81.0% (34/42), 100% (54/54), 91.7% (88/96) in TB-Feron Plus kit and 78.6% (33/42), 100% (54/54), 90.6% (87/96) in BOVIGAM® kit, respectively. Moreover, the overall accordance percentage of the two kits was 99.0% (95/96) and there was almost perfect agreement between two assays (Kappa=0.977, P<0.0001). Furthermore, additional studies confirmed that elevated lymphocyte numbers in blood did not interfere with the results of the TB-Feron Plus kit. And, delayed time from sampling to culture decreased the optical density (OD) value. Therefore, we concluded that the TB-Feron Plus kit was not inferior to BOVIGAM® in performance. High lymphocyte numbers in blood did not impact on TB-Feron Plus results, while delayed time before culture interfered with OD value.

Clinical assessment of periodontitis in dogs using the MiriChekTM Oral Bacter test kit: An in vivo study (MiriChekTM Oral Bacter test kit를 활용한 개 치주염의 임상적 평가)

  • Choi, Hyuck;Roh, Jae-Hee;Kim, Yun-Jeong;Hwang, In-Soo;Park, Woo-Dae;Kim, Min-Seok;Jeong, Young-Eui
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.337-348
    • /
    • 2021
  • Objectives: To determine the usefulness of MiriChekTM Oral Bacter as compared to traditional clinical methods in the periodontal assessment of dogs with and without periodontitis. Methods: In this study, 61 dogs were clinically examined using the MiriChekTM Oral Bacter test kit, and information regarding breed, age (months), sex, weight, presence of disease, and periodontitis stage was recorded. The test used a sample of supragingival plaque from the upper left premolar of the dogs. Results: This study included 30 and 31 dogs with and without periodontitis, respectively. Periodontitis was more common in older dogs than in younger dogs. The average positive and negative sensitivity rates of the MiriChekTM Oral Bacter test kit were 73.3% and 80.7%, respectively, and were both strongly correlated with the severity of periodontitis. Conclusions: The findings of this study encourage the use of new diagnostic assist test kits, such as MiriChekTM Oral Bacter, for appropriately detecting and diagnosing periodontal disease in dogs.

Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship (시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1044-1053
    • /
    • 2022
  • Time domain reflectometry (TDR) is a diagnostic technique to evaluate the physical integrity of cable and finds application in leak detection and localization of piping system. In this study, a cable-shaped leak detection sensor was proposed using the TDR technique for monitoring leakage detection of ship's engine room seawater piping system. The cable sensor was developed using a twisted pair arrangement and wound by an absorbent material. The availability and performance of the sensor for leak detection and localization were evaluated on a lab-scale pipeline set up. The developed sensor was installed onto the pipes and flanges of the lab-scale set up and various TDR waveforms were acquired and analyzed according to the dif erent variables including the number of twists and sheath thickness. The result indicated that the twisted cable sensor was able to produce clear and smooth signal as compared to the TDR sensor with a parallel arrangement. The optimal number of twist was determined to be above 10 per the unit length. The optimal diameter of sheath thickness that results in the desired sensitivity was determined to be ranging from 80% up to 120% of the diameter of the conductor. The linear regression analysis for estimation of leak localization was carried out to estimate the location of the leakage, and the result was a determination coefficient of 0.9998, indicating a positive relationship with the actual leakage point. The proposed TDR based leak detection method appears to be an effective method for monitoring leakage of ship's seawater piping system.

Efficiency and accuracy of artificial intelligence in the radiographic detection of periodontal bone loss: A systematic review

  • Asmhan Tariq;Fatmah Bin Nakhi;Fatema Salah;Gabass Eltayeb;Ghada Jassem Abdulla;Noor Najim;Salma Ahmed Khedr;Sara Elkerdasy;Natheer Al-Rawi;Sausan Alkawas;Marwan Mohammed;Shishir Ram Shetty
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.193-198
    • /
    • 2023
  • Purpose: Artificial intelligence (AI) is poised to play a major role in medical diagnostics. Periodontal disease is one of the most common oral diseases. The early diagnosis of periodontal disease is essential for effective treatment and a favorable prognosis. This study aimed to assess the effectiveness of AI in diagnosing periodontal bone loss through radiographic analysis. Materials and Methods: A literature search involving 5 databases (PubMed, ScienceDirect, Scopus, Health and Medical Collection, Dentistry and Oral Sciences) was carried out. A specific combination of keywords was used to obtain the articles. The PRISMA guidelines were used to filter eligible articles. The study design, sample size, type of AI software, and the results of each eligible study were analyzed. The CASP diagnostic study checklist was used to evaluate the evidence strength score. Results: Seven articles were eligible for review according to the PRISMA guidelines. Out of the 7 eligible studies, 4 had strong CASP evidence strength scores (7-8/9). The remaining studies had intermediate CASP evidence strength scores (3.5-6.5/9). The highest area under the curve among the reported studies was 94%, the highest F1 score was 91%, and the highest specificity and sensitivity were 98.1% and 94%, respectively. Conclusion: AI-based detection of periodontal bone loss using radiographs is an efficient method. However, more clinical studies need to be conducted before this method is introduced into routine dental practice.

Rehabilitation with minimal increase in occlusal vertical dimension in a patient with excessive tooth wear and edge-to-edge bite (과도한 치아 마모와 절단교합을 보이는 환자에서 최소한의 수직 고경 증가를 통한 구강회복 증례)

  • Hee-Young Kim;Seong-A Kim;Yong-Sang Lee;Keun-Woo Lee;Joo-Hyuk Bang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.143-152
    • /
    • 2023
  • Although tooth wear is a normal process due to aging, severe tooth wear causes various complications such as increased tooth sensitivity, loss of tooth structure, and pulp complications. In the treatment of patients with excessive tooth wear, the evaluation of loss of vertical occlusal dimension should be prioritized. If it is necessary to increase the vertical dimension to secure the restoration space, it is important to establish a treatment plan with the comprehensive analysis and determine the minimum vertical dimension elevation. In this case, 66-year-old male patient with severe worn dentition wanted to restore masticatory function and improve esthetic restoration. In order to determine the appropriate vertical dimension of the patient, we evaluated oral examination, radiographic examination, and diagnostic cast examination, and performed rehabilitation with minimum vertical dimension elevation. As a result of observation for 8 months, the definitive prosthesis was completed with contact of all teeth in centric occlusion, and proper anterior/posterior guidance. Through the above process, satisfactory aesthetic and functional outcomes were obtained.

The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography (근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성)

  • Shin, Duk-Seop;Na, Ho Dong;Park, Jae Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.509-518
    • /
    • 2019
  • Purpose: Lymph node metastasis is a very important prognostic factor for all skin cancers and some sarcomas. A sentinel lymph node (SLN) biopsy is the most useful technique for identifying SLNs. Recently, a new generation of diagnostic tools, such as single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) enabled the detection of SLNs. This study compared the efficacy of PET/CT for detecting lymph node metastases with a SLN biopsy in a single medical center. Materials and Methods: From 2008 to 2018, 72 skin cancers of sarcoma patients diagnosed with some lymph node involvement in a whole body PET/CT reading were assessed. Patients suspected of lymph node metastasis were sent to biopsy and those suspected to be reactive lesions were observed. The analysis was performed retrospectively using the medical records, clinical information, PET/CT readings, and pathology results. Results: The age of patients ranged from 14 to 88 years and the mean follow-up period was 2.4 years. Twenty-two patients were suspected of a lymph node metastasis and confirmed. The sensitivity, specificity, positive predictive value and negative predictive value of PET/CT images in sarcoma and non-sarcoma tumors were increased significantly when the expert's findings were considered together. Conclusion: PET/CT is effective in detecting lymph node metastases.

Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes (CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가)

  • Byeong-Je Kim;Dong-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.801-808
    • /
    • 2023
  • In order to minimize radiation exposure and secure diagnostic value images during CT examination of the head of children, the usefulness of volume axial mode is evaluated through comparison and analysis of exposure dose and images of volume axial mode, high pitch mode, and helical mode. Image evaluation and dose evaluation were performed in CT high pitch mode, helical mode, and volume axial mode for infants under the age of 1 according to the voltages of 70, 80, and 100 kVp tubes. The image evaluation was conducted by comparing image quality by setting ROI for each image, calculating SNR and CNR, using ONE-WAY (ANOVA) to evaluated statistical significance, and cross-examining the dose evaluation using DLP values displayed in the Dose Report. When inspected using volume axial mode, DLP values were generally low, and SNR and CNR values differed by ROI and kVp. When volume axial mode evaluated the quality of the image compared to other scan modes, the difference is not uniform. For the reason, certain modes are not considered excellent, but the exposure dose was reduced the most in terms of dose. In addition, the point that the volume axial mode can be examined at its original location, short scanning time and needless of table movement is useful for CT tests for children under 1 year of age with high radiation sensitivity.