• Title/Summary/Keyword: diagnostic method

Search Result 2,477, Processing Time 0.047 seconds

MODELING FOR PROBING THE PHYSICAL STATES OF HII REGIONS (전리수소 영역의 물리량 측정을 위한 방출선 모형연구)

  • Sung, Hyun-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.26 no.1
    • /
    • pp.25-35
    • /
    • 2011
  • A diagnostic tool has been proposed to convert the observed surface distribution of hydrogen recombination line intensities into the radial distributions of the electron temperature and the density in HII regions. The observed line intensity is given by an integral of the volume emission coefficient along the line of sight, which comprises the Abel type integral equation for the volume emission coefficient. As the emission coefficient at a position is determined by the temperature and density of electrons at the position, the local emission coefficient resulted from the solution of the Abel equation gives the radial distribution of the temperature and the density. A test has been done on the feasibility of our diagnostic approach to probing of HII regions. From model calculations of an HII region of pure hydrogen, we have theoretically generated the observed surface brightness of hydrogen recombination line intensities and analyzed them by our diagnostic tool. The resulting temperatures and densities are then compared with the model values. For this case of uniform density, errors in the derived density are not large at all the positions. For the electron temperature, however, the largest errors appear at the central part of the HII region. The errors in the derived temperature decrease with the radial distance, and become negligible in the outer part of the model HII region.

The Study to Diagnose the Road-Driver Compatibility I: Comparison of Methods for Bio-Signal Analysis (운전자 주행 적합성 진단을 위한 연구 I: 생체신호 분석방법 비교)

  • Kim, Jung-Yong;Yoon, Sang-Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.1
    • /
    • pp.44-49
    • /
    • 2004
  • The aim of this study is to compare the methods in analyzing bio-signals representing measure driver's psychophysiological staus. This study has considered three approaches: first, the deterministic approach calculating the mean and standard deviation of bio-signal, second, probabilistic approach converting driver's bio-signal values to probability density function and identifying individual state relative to overall distribution, and third, diagnostic approach identifying the pattern change of signal over certain period of time. For evaluation of analysis methods, driver's bio-signal was collected under various road conditions, and three analysis approaches were applied respectively. In result, the deterministic approach was found to be simple to use, but generated a large variability of bio-signal. The probabilistic approach provide a relative status of individual driver among overall population, but too much affected by temporal variability of individual driver. The diagnostic approach seemed to reasonably find driver's psychophysiological change over certain period of time, but still needs to develop quantification method of the bio-signal.

Development of the Software to test Pattern Diagnosis Ability in Oriental Medicine (변증 능력 평가 소프트웨어의 구현)

  • Kim, Ki-Wang;Chang, Jae-Soon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.1
    • /
    • pp.70-78
    • /
    • 2010
  • Objectives : To qualify or enhance the diagnostic ability of students in Oriental Medicine, so called standardized patients are ideal modality, but because it's a man-based method, more convenient tools are required. Computer-based diagnostic ability test program gives effective way for the very purpose. So we made a pilot software evaluating Pattern Identification ability in Oriental Medicine. Methods and Materials : The pilot software was coded with Microsoft's EXCEL VBA. 87 names of Zheng (Symptom Pattern) and 674 names of symptom (including some signs) are adopted from the former standardization works conducted by Korean Institute of Oriental Medicine (KIOM) in 1996. Results : Compared with some manned modalities to test Pattern Identification ability, the test by this software shows superiority in convenience and objectivity. Conclusion : This software is world's first program to perform computer-based evaluation of Pattern Identification in Oriental Medicine, and it gives effective way to complement both written test and manned clinical performance test (CPX).

Development of the Power System Fault Diagnostic Algorithm for the Proton Accelerator Research Center of PEFP (양성자가속기 연구센터 전력계통 고장진단 알고리즘 개발)

  • Mun, Kyeong-Jun;Jeon, Gye-Po;Lee, Seok-Ki;Kim, Jun-Yeon;Jung, W.;Yoo, Suk-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.685-686
    • /
    • 2007
  • This paper presents an application of power system fault diagnostic algorithm for the PEFP Proton Accelerator Research Center using neural network. Proposed fault diagnostic system is constructed by the radial basis function (RBF) neural network because it has the capabilities of the pattern classification and function approximation of any nonlinear function. Proposed system identifies faulted section in the power system based on information about the operation of protection devices such as relays and circuit breakers. In this paper, parameters of the RBF neural networks are tuned by the GA-TS algorithm, which has the global optimal solution searching capabilities. To show the validity of the proposed method, proposed algorithm has been tested with a practical power system in Proton Accelerator Research Center of PEFP.

  • PDF

Educational Needs Based on Analysis of Importance, Frequency and Difficulty of ICU Nursing Practice for ICU Nurses (중환자실 간호실무의 중요도, 수행 빈도 및 난이도 분석을 통한 중환자실 간호사의 교육요구도)

  • Kim, Keum-Soon;Kim, Jin-A;Park, Young-Rye
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.3
    • /
    • pp.373-382
    • /
    • 2011
  • Purpose: The purpose of this study was to assess the educational needs of ICU nurses based on an analysis of importance, frequency, and difficulty for ICU nursing practice. Method: A cross-sectional survey was conducted using a questionnaire with 80 questions in 14 ICU nursing categories. Data were collected from August to October 2009. A total of 295 ICU nurses from five hospitals who had minimum of one year clinical experience participated. Data were analyzed with using descriptive statistics. Results: For importance, emergency care had the highest score, followed by physical assessment, communication, cardiovascular care, and ICU basic nursing. Regarding the frequency, physical assessment had the highest score, followed by communication, medication, ICU basic nursing, and respiratory care. Cardiovascular care was the most difficult task, followed by neurological care, emergency care, other ICU related nursing care, diagnostic test, and communication. Conclusion: The findings indicate a high educational need in the areas of communication, medication, physical assessment, diagnostic test, emergency care, and cardiovascular care. Thus the development of educational programs on communication, medication, physical assessment, diagnostic test, emergency care, and cardiovascular care are needed for ICU nurses.

Measurement of Apnea Using a Polyvinylidene Fluoride Sensor Inserted in the Pillow (베게에 삽입된 PVDF센서를 이용한 무호흡증 측정)

  • Keum, dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.407-413
    • /
    • 2018
  • Most sleep apnea patients exhibit severe snoring, and long-lasting sleep apnea may cause insomnia, hypertension, cardiovascular diseases, stroke, and other diseases. Although polysomnography is the typical sleep diagnostic method to accurately diagnose sleep apnea by measuring a variety of bio-signals that occur during sleep, it is inconvenient as the patient has to sleep with attached electrodes at the hospital for the diagnosis. In this study, a diagnostic pillow is designed to measure respiration, heart rate, and snoring during sleep, using only one polyvinylidene fluoride (PVDF) sensor. A PVDF sensor with piezoelectric properties was inserted into a specially made instrument to extract accurate signals regardless of the posture during sleep. Wavelet analysis was used to identify the extractability and frequency domain signals of respiration, heart rate, and snoring from the signals generated by the PVDF sensor. In particular, to separate the respiratory signal in the 0.2~0.5 Hz frequency region, wavelet analysis was performed after removing 1~2 Hz frequency components. In addition, signals for respiration, heart rate, and snoring were separated from the PVDF sensor signal through a Butterworth filter and median filter based on the information obtained from the wavelet analysis. Moreover, the possibility of measuring sleep apnea from these separated signals was confirmed. To verify the usefulness of this study, data obtained during sleeping was used.

Validation of Synovial Fluid Clinical Samples for Molecular Detection of Pathogens Causing Prosthetic Joint Infection Using GAPDH Housekeeping Gene as Internal Control

  • Jiyoung Lee;Eunyoung Baek;Hyesun Ahn;Youngnam Park;Geehyuk Kim;Sua Lim;Suchan Lee;Sunghyun Kim
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.220-230
    • /
    • 2023
  • Identification of the pathogens causing infection is important in terms of patient's health management and infection control. Synovial fluids could be used as clinical samples to detect causative pathogens of prosthetic joint infections (PJIs) using molecular diagnostic assays, therefore, normalization and validation of clinical samples are necessary. Microbial culture is considered the gold standard for all infections, including PJIs. Recently, molecular diagnostic methods have been developed to overcome the limitation of microbial culture. Therefore, guideline for validating clinical samples to provide reliable results of molecular diagnostic assays for infectious diseases is required in clinical field. The present study aimed to develop an accurate validating method of synovial fluid clinical samples using GAPDH gene as an internal control to perform the quantitative PCR TaqMan probe assay to detect pathogens causing PJIs.

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

Endoscopic Diagnosis and Treatment of Benign Small Bowel Stricture (양성 소장협착의 내시경적 진단과 치료)

  • Jinsu Kim
    • The Korean Journal of Medicine
    • /
    • v.99 no.4
    • /
    • pp.199-205
    • /
    • 2024
  • Benign small bowel strictures can occur in association with various conditions, including small bowel Crohn's disease, nonsteroidal anti-inflammatory drug-induced enteritis, ischemic enteritis, intestinal tuberculosis, radiation enteritis, postoperative adhesions, and anastomotic strictures. Benign small bowel strictures are classified into two categories, low-grade and high-grade. Low-grade small bowel strictures involve a partial reduction of the internal diameter of the small intestine, causing slight obstruction of the passage of food and digestive fluids without significant bowel obstruction symptoms. By contrast, high-grade small bowel strictures involve a severe narrowing of the intestinal lumen, leading to marked obstruction of the passage of food and digestive fluids and pronounced bowel obstruction symptoms. Small bowel strictures can be diagnosed using various methods, including abdominal plain radiography, abdominal computed tomography, computed tomography enterography, magnetic resonance enterography, balloon-assisted enteroscopy, and abdominal ultrasound. Each diagnostic method has unique advantages and disadvantages as well as differences in diagnostic specificity and sensitivity. Therefore, even if small bowel strictures are not observed using a single imaging technique, their presence cannot be completely excluded. A comprehensive diagnosis that combines clinical information from multiple diagnostic modalities is necessary. Therapeutic approaches for managing small bowel strictures include medical therapy, endoscopic balloon dilation using balloon-assisted enteroscopy, and surgical methods such as strictureplasty and segmental resection. Endoscopic balloon dilation, in particular, can help reduce complications associated with repeated surgeries for strictures.

A Study on the Necessity of Verification and Certification System of Inspection and Diagnostic Equipment for Infrastructure using Advanced Technologies (첨단 시설물 점검 및 진단장비 검·인증제도 도입 필요성에 대한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Twae-Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.163-177
    • /
    • 2020
  • Purpose: While it is very important to maintain facilities recently, the introduction and its application of high technology in the facility maintenance industry has increased. It is necessary for high technology to secure reliability through the verification and certification system of diagnostic equipment to have an effective impact in the field, but there is difference between the industry's perspective and realistic level of technology apart from social demand for the system of the system. This paper dealt with the introduction of a verification and certification system for rational facility diagnostic equipment with the opinion survey on managers about the current situation. Method: Survey is carried out targeting managers in the maintenance and construction regarding the necessity and urgency of introducing a verification and certification system to promote the introduction and its application of high technology of diagnostic equipment and facility inspection. Also, the introduction to a verification and certification system was reviewed for advanced facility diagnostic equipment through foreign research about similar systems and comparative analysis of similar systems related to the certification of 21 domestic equipment. Result: It showed that, regarding the application of high technology, it is necessary for most managers to introduce high technology such as drones, robots, etc., in the maintenance industry, and when high technology is introduced, it will have a considerable effect in the field. On the other hand, the current technology level in Korea is relatively low, so it turned out to take a certain amount of time for the application of technology. Also, it was found that the management of reliable facility diagnostic equipment will be possible through the introduction of the verification and certification system for facility diagnosis equipment. Meanwhile, the survey is conducted on similar systems about foreign and domestic diagnosis and measuring equipment, etc., but there is no system to verify and certify equipment applied with high technology directly to facility diagnosis maintenance. However, because Japan has a system of verifying the performance of diagnostic equipment and South Korea has 21 similar inspection and diagnostic equipment certification systems among 186 certification systems, it is considered to be possible to design systems which utilize them. Conclusion: According to the managers' opinion, it seems that the introduction of the system supporting the application of 4th industrial technology for the equipment and the use of the equipment with high reliability has sufficient validity. However, because our high technology level is undervalued compared to the urgency, the system for checking high technology facilities and certifying diagnostic equipment should be to be implemented in form of escalation considering technical use and verification level. Apart from the introduction of the verification and certification system, it is necessary for special investment, support and efforts to promote advanced facility diagnostic equipment.