• Title/Summary/Keyword: diagnostic method

Search Result 2,427, Processing Time 0.031 seconds

Development of a Guideline for the Application of Diagnostic Devices for Menopausal Syndrome: Literature Review and Questionnaire Survey (갱년기장애 진단기기 사용에 대한 지침 개발 : 문헌검토 및 설문조사)

  • Baek, Seon-Eun;Park, Eun-Ji;Kim, Dong-Il;Lee, In-Seon;Yoo, Jeong-Eun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.3
    • /
    • pp.65-78
    • /
    • 2017
  • Objectives: This study was aimed to develop a guideline for the application of diagnostic devices for menopausal syndrome. Methods: We conducted a literature review and a questionnaire survey on diagnostic devices including Digital Infrared Thermal Imaging (DITI), pulse diagnosis device, Heart Rate Variability (HRV), body composition analyzer, Yangdorak. Results: We retrieved some clinical values for usage of devices from the articles. Especially, DITI was useful to identify the pattern of body temperature distribution. The respondents answered that they diagnosed menopausal syndrome by using body composition analyzer (62.3%), DITI (60%), HRV (60%), pulse diagnosis device (45.7%), Yangdorak (34.3%). The respondents answered that they don't use diagnostic devices when they diagnosed menopausal syndrome because of absence of device, cost, difficulty of interpretation, substitution of another diagnostic method. After experts survey, it was recommended to use DITI, HRV, body composition analyzer. There was no consensus on the use of pulse diagnosis device, Yangdorak in diagnosing menopausal syndrome. Conclusions: We developed a guideline for the application of diagnostic devices for menopausal syndrome.

A method for ultrasound image edge enhancement by using Probabilistic edge map (초음파 진단영상 대조도 개선을 위한 확률 경계 맵을 이용한 연구)

  • Choi, Woo-hyuk;Park, Won-hwan;Park, Sungyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Ultrasonic imaging is the most widely modality among modern imaging device for medical diagnosis. Nevertheless, medical ultrasound images suffer from speckle noise and low contrast. In this paper, we propose probabilistic edge map for ultrasound image edge enhancement using automatic alien algorithm. The proposed method used applied speckle reduced ultrasound imaging for edge improvement using sequentially acquired ultrasound imaging. To evaluate the performance of method, the similarity between the reference and edge enhanced image was measured by quantity analysis. The experimental results show that the proposed method considerably improves the image quality with region edge enhancement.

Clinical diagnostic study of Physiological Signal data measured on 58 cases of numbness with EAV(Electro-puncture According to Voll) (비증환자(痺證患者) 58례(例)에 대(對)한 EAV측정치(測定値)의 진단적(診斷的) 고찰(考察))

  • Han, Sang-Gyun;Ha, Chi-Hong;Cho, Myung-Rae;Ryu, Chung-Ryul;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.91-100
    • /
    • 2001
  • Background and Objective : Most diagnostic method for numbness were invasive and complex. So we need to simplify and objectify diagnostic method for numbness. Some study with EAV which is one of Physiological Signal Measuring Instruments, report significantly result as objective diagnostic method for other clinical symptom. By using EAV, we have obtained some physiological signal data from meridian-acupoints of 58 numbness cases. Objective and Methods : This study researched into the clinical statistics for 58 case who ware in numbness, and they ware treated with oriental medical care at the Dong-shin university oriental hospital during 1 year from April 3 2000 to March 30 2001. The data were analyzed and interpreted to compare with traditional differentiation of symptom-complexes, then further evaluated as the Five Evolutive Phases to make them differentiated. The EAV valus of Five Evolutive Phases were identified with the sequence of wood(木), fire(火), earth(土), steel(金), water(水). Results and Conclusion : These values of physiological signal were identical with standard differentiation of symptom-complexes of numbness which is the main cause of dishannonious flow of Qi and blood of the in the liver and deficiency of Qi and blood of the bladder with stagnancy of dampness. Among Five Evolutive Phases, Earth and wood values were increased, steel, fire and water were decreased significantly. This data imply the possibility of somewhat generalization from measuring instruments.

  • PDF

Establishment of an Optimal Rehabilitation Process for Agricultural Public Wells by Applying Standardized Diagnostic Functions (농어업용 공공관정 기능진단 표준화(안)을 이용한 최적 사후관리)

  • Lee, Byung Sun;Song, Sung-Ho;Park, Jeong-Keun;Won, Young-Cheon;Kim, Wonsuck
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • Rehabilitation for low-yielding wells resulting in improvement on groundwater quantity and quality is considered to be the most economic and ecofriendly method against the increasing demand to groundwater due to frequent drought and the increase in numbers of agricultural complex for growing horticultural crops. This study suggests standard, stepwise diagnostic fuctions consisting of four steps (Basic inspection, Specific inspection, Rehabilitation, and Management) for an optimal management to the wells. Basic inspection can provide information on current groundwater quantity and quality compared with those on its initial stage. Specific-inspection based on hydrogeology can scientifically demonstrate causes of deterioration on groundwater quantity and quality. Results of specific inspection can suggest an optimal rehabilitation method to solve deteriorating problems including clogging and corrosion for the wells. After rehabiliating the wells, an assessment on groundwater quantity and quality would be conducted to identify the suitability of the applied method and improvement of the wells. A short-term, periodic management to the wells is considered as the key to save a public management budget. Suggested diagnostic functions can possibly induce sustainable supply of agricultural groundwater to the farm land and finally contribute the increase on rural household income.

Nested-PCR and a New ELISA-Based NovaLisa Test Kit for Malaria Diagnosis in an Endemic Area of Thailand

  • Thongdee, Pimwan;Chaijaroenkul, Wanna;Kuesap, Jiraporn;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.4
    • /
    • pp.377-381
    • /
    • 2014
  • Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

Establishment of a diagnostic method for porcine proliferative enteropathy using polymerase chain reaction (중합효소연쇄반응을 이용한 돼지 증식성 장염 진단기법 확립)

  • Lym, Suk-kyung;Lee, Hee-soo;Woo, Sung-ryong;Yoon, Soon-seek;Moon, Oun-kyong;Lee, Yoo-young;Koh, Hong-bum
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.118-125
    • /
    • 1999
  • Porcine Proliferative Enteropathy(PPE) is an infectious enteric disease and a major cause of economic loss in swine industry due to weight loss, poor growth and sudden death in growing and finishing pigs at 6 to 20 weeks of age. PPE has been diagnosed by clinical signs, syndrom and lesions in the intestine in Korea. However, the diagnostic method had several problems in the detection of infected or carrier pigs. Therefore, in this study, we established the polymerase chain reaction(PCR) which was a fast, specific and sensitive method for identification of Lawsonia intracellularis (L intracellularis). We designed and synthesized primer on the 16S rDNA and p78 gene encoding L intracellularis. Specificity of the method was confirmed by comparison of the PCR results using other enteric bacteria and the study has shown that PCR method was sensitive to detect 1ng of genomic DNA as a template. Identity of the PCR products was confirmed by comparison of pattern of restriction endonuclease analysis with restriction enzyme Hae III and Pst I. Also, the PCR method was applicable to the naturally affected pigs with PPE. Based on the results from this study, the PCR method could be used as a fast and specific diagnostic tool for PPE.

  • PDF

Diagnostic Method for the Detection of JC Polyomavirus Using Loop-mediated Isothermal Amplification (등온증폭법을 이용한 고감도 JC polyomaviruses 진단법 개발)

  • Cho, Kyu Bong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.414-419
    • /
    • 2019
  • JC polyomavirus (JCPyV) is a human pathogenic virus belonging to the family Polyomaviridae, a viral group containing dsDNA nucleic acid. A recent recommendation is to apply the presence of JCPyV as a fecal indicator for water contamination in environments like sewage, and techniques to monitor JCPyV in water are being proposed. To date, the conventional PCR system has been applied as a diagnostic method for detecting JCPyV. There is a need for a more rapid and sensitive JCPyV diagnostic detection method in clinical and environmental samples. In this study, we developed a loop-mediated isothermal amplification (LAMP) primer set for the detection of JCPyV. Our results indicate that the LAMP method using a specific primer set shows about 10-fold higher detection sensitivity than the conventional PCR system. The effectiveness of the LAMP method developed in this study has been validated by PCR product digestion using the HaeIII restriction enzyme. We, therefore, propose that the LAMP method using a specific primer set can be applied as a rapid and sensitive detection method for monitoring JCPyV in clinical and environmental samples.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Diagnostic Method for Logistics Services Level on National Industrial Complexes, Airports and Seaports (국가산업단지 및 수출입 공항·항만의 물류서비스 수준 진단방법 개발)

  • HUR, Sung Ho;JEONG, Seung-Ju
    • Journal of Korea Port Economic Association
    • /
    • v.35 no.1
    • /
    • pp.97-116
    • /
    • 2019
  • National industrial complexes, airports, and seaports are major logistics nodes and the availability of their logistics services is a key factor for the successful operation of entire supply chains. For this reason, the central government has established a plan for their development and is investing in development projects. However, some difficulties exist in project prioritization and investment plan creation owing to the absence of a clear appraising method. For a smooth flow of national logistics and efficient investment on facilities, it is necessary to diagnose the logistics facilities' present conditions and practice sustainable management. In this study, a diagnostic method for logistics services, which consists of service factors and facility factors, is proposed. Adopting the method, facility factors can be prioritized to improve facilities' services; further, a standard procedure is proposed to support decision making for effective investments in logistics facilities. The method is applied to actual logistics facilities (three national industrial complexes, three seaports, and two airports) and the results indicate that it can be effectively applied to actual logistics facilities.