• Title/Summary/Keyword: diagnostic method

Search Result 2,451, Processing Time 0.034 seconds

Development of a Web-based Diagnostic Evaluation Program for Prevention of Nurse Malpractice Liability (간호과오책임 예방을 위한 웹기반 진단평가 프로그램 개발)

  • Kim, Ki-Kyong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.1
    • /
    • pp.33-43
    • /
    • 2011
  • Purpose: This study was done to develop a web-based diagnostic evaluation program for nurses to prevent malpractice liability. Methods: A comprehensive review of the literature and 9 specialist interviews were used to search for learning goals and content for protection for nurses from malpractice. Data on needs for learning goals were collected from 56 hospital nurses who agreed to complete a self-report questionnaire. The diagnostic program was evaluated between September 2008 and August 2009 by 35 new hospital nurses using an application of the web-based program evaluation tools by Chung (2000). Results: A comprehensive review of the literature and interviews were used to search for learning goals and content. The evaluation program was composed of the 73 questions for diagnostic evaluation under 23 learning goals and 6 grand learning goals which included the principles of law, patient's rights, legal responsibility, patient's safety, regulation on nursing practice and patient's rights protection. Evaluation of the program showed that the mean for program evaluation was 3.43 (SD=.37). Conclusion: This diagnostic evaluation program could be an efficient method for teachers and learners to improve nurses' behavior in protecting the patient's rights and preventing malpractice claims.

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

The Usefulness of $SurePath^{TM}$ Liquid-Based Smear in Sono-Guided Thyroid Fine Needle Aspiration; a Comparison of a Conventional Smear and $SurePath^{TM}$ Liquid-Based Cytology (초음파 유도 갑삼샘 세침흡인 세포검사에서 $SurePath^{TM}$ 액상세포검사의 유용성; 고식적 도말검사와 $SurePath^{TM}$ 액상세포검사와의 비교)

  • Kim, Dong-Hoon;Kim, Min-Kyung;Chae, Seoung-Wan;Lee, Kyoung-Bun;Han, Eun Mee;Kang, Sung-Hee;Sohn, Jin-Hee
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.143-152
    • /
    • 2007
  • Sono-guided fine needle aspiration (FNA) of the thyroid is widely used, but the aspirated samples are typically not well preserved and low cellularity makes diagnosis difficult in many cases. The object of the current study is to evaluate the adequacy and diagnostic accuracy of the use of $SurePath^{TM}$ liquid-based cytology (SP-LBC) in the sonoguided fine needle aspiration of the thyroid nodule and to compare its use with that of the use of a conventional smear (CS). A total of 172 sono-guided FNAs of thyroid nodules from April to June, 2006 were prepared by the use of the split method with either SP-LBC or CS; the samples were stained with the use of hematoxylin-eosin (H&E) and Papanicolaou (Pap) stains. A cyto-histological correlation was performed in 69 (30 SP and 39 CS) cases that had been histologically confirmed. The rate of producing unsatisfactory slides by the use of the SP-LBC method (9.3%) was less than that of the use of the CS method (20.9%). The diagnostic accuracy of the SP method (93.3%) was better than that of the CS method (85.3%). The sensitivity and specificity of the SP method (94.4% and 92.3%) was better than that of the CS method (83.3% and 70%), respectively (p < 0.05). The CS of sono-guided aspirated specimens had some unavoidable limitations related to inadequate sampling such as a bloody background, low cellularity and an indication that some clinicians smeared many useless slides (averaging four to ten slides), and that most slides showed only blood that included few follicular cells. The SP method resulted in more thinly smeared slides and showed cleaner background and greater cellularity than the use of the CS method. Each follicular cell shows superior nuclear detail, and more distinct cytoplasmic features than with the use of the CS method. SP-LBC appears to be an easy, highly accurate, and reliable cytological method for employ for a diagnostic approach of thyroid disease and thyroid nodules. The SP-LBC method is a suitable alternative to the CS method to overcome diagnostic difficulties.

Rapid Detection and Identification of Wuchereria bancrofti, Brugia malayi, B. pahangi, and Dirofilaria immitis in Mosquito Vectors and Blood Samples by High Resolution Melting Real-Time PCR

  • Thanchomnang, Tongjit;Intapan, Pewpan M.;Tantrawatpan, Chairat;Lulitanond, Viraphong;Chungpivat, Sudchit;Taweethavonsawat, Piyanan;Kaewkong, Worasak;Sanpool, Oranuch;Janwan, Penchom;Choochote, Wej;Maleewong, Wanchai
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.6
    • /
    • pp.645-650
    • /
    • 2013
  • A simple, rapid, and high-throughput method for detection and identification of Wuchereria bancrofti, Brugia malayi, Brugia pahangi, and Dirofilaria immitis in mosquito vectors and blood samples was developed using a real-time PCR combined with high-resolution melting (HRM) analysis. Amplicons of the 4 filarial species were generated from 5S rRNA and spliced leader sequences by the real-time PCR and their melting temperatures were determined by the HRM method. Melting of amplicons from W. bancrofti, B. malayi, D. immitis, and B. pahangi peaked at $81.5{\pm}0.2^{\circ}C$, $79.0{\pm}0.3^{\circ}C$, $76.8{\pm}0.1^{\circ}C$, and $79.9{\pm}0.1^{\circ}C$, respectively. This assay is relatively cheap since it does not require synthesis of hybridization probes. Its sensitivity and specificity were 100%. It is a rapid and technically simple approach, and an important tool for population surveys as well as molecular xenomonitoring of parasites in vectors.

Development of Performance Indices for Agro-food Distribution Corporations Based on the AHP Method (AHP기법을 이용한 농식품 유통법인 경영진단지표 개발)

  • Kim, Dong-Hwan;Hyun, Jong-Ki
    • Journal of Distribution Science
    • /
    • v.15 no.12
    • /
    • pp.95-102
    • /
    • 2017
  • Purpose - This study aims to develop diagnostic indices for managerial performance of agro-food distribution corporations. In particular, weights of diagnostic indices were estimated using the AHP method. Management diagnosis on agro-food distribution corporations is expected to increase their competitiveness in the domestic market as well as in international markets. Research design, data, and methodology - It develops weights or importance of the diagnostic indices based upon the survey of 21 experts in food distribution management. The survey was carried out using e-mail. Management diagnostic indices were developed based upon four BSC(Balanced Scorecard) perspectives of finance, learning/growth/leadership, customer, and internal process/technology. Results - Diagnostic indices on financial perspective consist on profitability, productivity, growth, stability and activity. Learning and leadership perspective indices consist of management will, CEO leadership, level of learning, innovation, and level of management information system. Customer perspective indices are branding, customer and channel management and internal process/technology indices consist of fourteen sub-indices representing technologies, efficiency, and dynamics. It was estimated that the weight of financial perspective index was 0.3, internal process/technology perspective index 0.248, customer category index 0.247, and learning, growth and leadership perspective index 0.205. This study also estimates weights of sub-indices for managerial diagnosis by four different perspectives. Estimated weight of profitability (0.085) is the greatest among financial perspective indices, followed by stability (0.072), growth (0.053), productivity (0.051), and activity (0.038). While estimated weights of leadership, capability, and information indices are 0.100, 0.061, and 0.044 respectively, weights of marketing, customer management, and quality and service indices are 0.104, 0.093, and 0.051, respectively. Among internal process/technology perspective, estimated weights of efficiency, technology, and innovation indices are 0.106, 0.088, and 0.054, respectively. Conclusions - The diagnostic indices for managerial performance of agro-food distribution corporations would be utilized by agro-food distribution corporations themselves, extension service institutions, and consultants. It is also expected that central and local governments use diagnostic indices developed in this study for the purpose of evaluating the effects of governmental support programs for agro-food distribution corporations. Futhermore researchers and consultants would modify diagnostic indices developed in this study, reflecting characteristics and situation of types of agro-food distribution corporations.

Evaluation of the Malaria Rapid Diagnostic Kit in Ganghwa County (강화군에서 시행한 말라리아 신속진단킷트의 유용성 평가)

  • Kweon, Su-Jung;Kweon, Oh-Jun;Youn, Sung-Tae;Yim, Jun;Im, Jeong-Soo
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Objectives: Early diagnosis and treatment is the most important strategy to control malaria effectively. Microscopic examination of blood films is a traditional and standard method for diagnosing malaria, which takes a long time and needs expertise, Therefore, the alternative method, rapid diagnostic kit has been used for quick diagnosis in some counties, a highly infectious region by P. vivax. The purpose of this study was to evaluate the utility of malaria rapid diagnostic kit in Ganghwa county. Methods: The utility was evaluated by mean diagnosis time and sensitivity and specificity. For monitoring mean diagnosis time, 942 cases which were diagnosed for P. vivax were collected between 1998 and 2005, And for calculating sensitivity and specificity, 434 whole bloods in EDTA which were presented for P. vivax by microscopy and rapid diagnostic kit were collected between 2004 and 2005. Results: After malaria rapid diagnostic kit was used in 2003, mean diagnosis time has decreased to 3.36-3.14 day. The sensitivity and specificity of the rapid diagnostic kit was 98.2% and 98,5% and comparable to that of microscopic examination. Conclusions: The malaria rapid diagnostic kit is useful tool in a highly infectious region like Ganghwa county.

  • PDF

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Clinical Studies about diagnostic Yields according to Variable Diagnostic Methods in Lung Cancer (폐암에서 각종 진단수기에 따른 진단율에 관한 연구)

  • Kang, Dae-Song;Cho, Jin-Ung;Kim, Sang-Gyun;Kim, Mi-Ae;Yang, Sung-Uk;Lee, Tae-Quan;Lee, Tae-Hun;Kim, Kwi-Wan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.700-708
    • /
    • 1993
  • Background: Lung cancer has become one of the most common cancers in Korea. It is important to determine the accurate histologic types and stages because of different therapeutic modlaity, especially in small cell carcinoma. This study was designed to evaluate diagnostic yields according to variable diagnostic methods in lung cancer. Methods: The records of 683 patients with a confirmed diagnosis of primary lung cancer during the period of 7 years, from January, 1986 until December, 1992 at Presbyterian Medical Center were analyzed retrospectively. Results: 1) Age and sex distributions Male: female sex ratio was 5.57:1 and age distributions were 7th decade 41.4%, 6th decade 30.2%, 8th decade 17.0%, 5th decade 7.9%, 4th decade 2.5%, 9th decade 1.3%, and 3rd decade 0.2% in decreasing order. 2) The frequencies according to histologic cell types were squamous cell carcinoma 44.7%, small cell carcinoma 23.9%, adenocarcinoma 22.8%, alveolar cell carcinoma 2.5%, large cell carcinoma 1.2%. mixed forms 1.2%, undifferenciated cell carcinoma 0.6% and malignant fibrous histiocytoma 0.2%(1 case) in decreasing order. 3) The most common locations of lung cancer were in left upper lobe and right lower lobe, and no differences of diagnostic methods according to locations were noted. 4) In central lesions, bronchoscopic examination was very accurate and frequently used diagnostic method, and in peripheral lesions, transthoracic lung biopsy(TTLB) was apparent1y accurate method. 5) The diagnostic yields of bronchoscopic biopsy, bronchial brushing, sputum cytology, transthoracic lung biopsy and transbronchial lung biopsy(TBLB) were 81.3%, 57.5%, 31.1%, 69.6% and 61.6%, respectively. 6) The concordance rates between the histologic diagnosis with bronchial brushing and sputum-cytology were 91.3% and 98.4%, respectively. 7) It was appropriate in lung cancer to repeat sputum cytology 3 to 5 times. Conclusion: Bronchoscopic examination is important to determine the histologic cell types in lung cancer. In addition, we should be interrested in improving diagnostic yields of sputum cytology as an easy method.

  • PDF

Systematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children (아동에서의 적외선 체온 측정의 진단정확도 연구 : 체계적 문헌 고찰과 메타분석)

  • Park, Young Joo;Park, Seong-Hi;Kang, Chang-Bum
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.6
    • /
    • pp.746-759
    • /
    • 2013
  • Purpose: Infrared thermometers are increasingly used as a convenient, non-invasive assessment method for febrile children. However, the diagnostic accuracy of the infrared thermometer for children has been questioned, particularly in relation to sensitivity and specificity. The aim of this study was to evaluate diagnostic accuracy of infrared thermometers in febrile children. Methods: Articles published between 1966 and 2012 from periodicals indexed in the Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected, using the following keywords: 'infrared thermometer'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Nineteen diagnostic studies with high methodological quality, involving 4,304 children, were included. The results of meta-analysis showed that the pooled sensitivity, specificity and AUC (Area Under the Curve) of infrared tympanic thermometers in children over 1 year were 0.80 (95% CI 0.78, 0.81), 0.94 (95% CI 0.93, 0.95) and 0.95 respectively. However the diagnostic accuracy of infrared tympanic thermometers in children with hyperthermia was low. Conclusion: The diagnostic accuracy of infrared tympanic thermometer was similar to axillary and rectal thermometers indicating a need for further research to substantiate these findings in children with hyperthermia.

Evaluation of Sympathetic Innervation in Cardiomyopathy with $^{123}I-MIBG$ (심근병에서 $^{123}I-MIBG$ 영상을 이용한 교감신경기능의 평가)

  • Kim, Sun-Jung;Lee, Jong-Doo;Lee, Do-Yun;Park, Chang-Yoon;Ham, Jin-Kyung;Chung, Nam-Sik;Cho, Seung-Yun;Lee, Sung-Sook;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.195-202
    • /
    • 1993
  • $^{123}Iodine$-metaiodobenzylguanidine (MIBG) which is a norepinephrine analogue, can be used to evaluate the sympathetic innervation of the heart. In this study, cardiac imaging with $^{123}I-MIBG$ was performed in patients with 9 dilated cardiomyopathy, 2 ischemic cardiomyopathy and 1 acute myocardial infarction to evaluate the sympathetic nervous function. $^{123}I-MIBG$ imaging showed multifocal defects (8), diffuse defect (2), near non-visualization (2). The defects of MIBG scans were found to be larger and more severe on 4 hours image than 30 minutes. Heart to lung, heart to mediastinum ratios were decreased at 4 hours than those at 30 minutes. Measured LVEF values were not correlated with the severity of MIBG uptake. $^{99m}Tc-MIBI$ imaging was also performed in all patients to find the relationship with $^{123}I-MIBG$ scan. $^{99m}Tc-MIBI$ scan showed multifocal defects in 9 patients, diffuse defects in 1 patient and no defect in 2 patients. The defects are similar in size, severity and extent, but more larger and severe on $^{123}I-MIBG$ imaging. Therefore, cardiac $^{123}I-MIBG$ imaging is a useful method to evaluate the sympathetic nervous function in cardiomyopathy.

  • PDF