• 제목/요약/키워드: device attachment

검색결과 112건 처리시간 0.022초

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

쿨링패치 부착에 따른 태양광-열전 융합소자의 성능 연구 (Effect of cooling patches on performance of photovoltaic-thermoelectric hybrid energy devices)

  • 이재환;조경아;박윤범;김상식
    • 전기전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.716-720
    • /
    • 2021
  • 본 연구에서는 태양광소자와 열전소자로 이루어진 에너지 융합 발전소자에 쿨링패치를 적용하고 에너지 융합 발전소자의 성능을 조사하였다. 쿨링패치를 열전소자의 뒷면에 부착하였을 때, 에너지 융합 발전소자의 상층에 위치한 태양광소자의 온도가 저하되고 열전소자 양단의 온도차는 증가되었다. 태양광 복사 조도를 200 W/m2부터 1000 W/m2까지 증가시키면서 에너지 융합 발전소자의 성능을 측정해본 결과, 쿨링패치는 태양광의 조도가 증가할수록 에너지 융합 발전소자의 성능 향상에 효과적이었고 1000 W/m2에서는 42.1 mW까지 융합소자의 최대 출력 전력이 증가하였다. 본 연구에서는 쿨링패치를 에너지 융합 발전소자에 부착함으로써 에너지 융합 발전소자의 출력 전력이 27% 이상으로 증가하는 것을 확인하였다.

거북목 예방을 위한 텍스타일 센서 개발 (Development of Textile Sensors for Prevention of Forward Head Posture)

  • 김민석;박진희;김주용
    • 패션비즈니스
    • /
    • 제27권4호
    • /
    • pp.125-140
    • /
    • 2023
  • This study aimed to develop a smart wearable device for assessing the risk angle associated with turtle neck syndrome in patients with Video Display Terminal (VDT) syndrome. Turtle neck syndrome, characterized by forward head posture resulting from upper cross syndrome, leads to thoracic kyphosis. In this research, a stretch sensor was used to monitor the progression of turtle neck syndrome, and the sensor data was analyzed using a Universal Testing Machine (UTM) and the Gauge Factor (GF) calculation method. The scapula and cervical spine angles were measured at five stages, with 15-degree increments from 0° to 60°. During the experimental process, the stretch sensor was attached to the thoracic spine in three different lengths: 30mm, 50mm, and 100mm. Among these, the attachment method yielding the most reliable data was determined by measuring with three techniques (General Trim Adhesive, PU film, and Heat Transfer Machine), and clothing using the heat transfer machine was selected. The experimental results confirmed that the most significant change in thoracic kyphosis occurred at approximately 30° of forward head posture. Prolonged deformity can lead to various issues, highlighting the need for textile sensor solutions. The developed wearable device aims to provide users with real-time feedback on their turtle neck posture and incorporate features that can help prevent or improve the condition.

NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발 (Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC)

  • 조하경;조상우;조광연
    • 감성과학
    • /
    • 제23권2호
    • /
    • pp.51-60
    • /
    • 2020
  • 본 연구의 목적은 심박 측정용 기기 및 의류에 있어 배터리 충전 및 기기의 부피감으로 인한 불편함을 개선하고, 사용자 편의성을 고려하여 목적에 따른 심박 측정을 가능케 하는 심박 측정용 스마트 의류 시스템을 개발하고자 하였다. 심박 측정 기기는 2가지 타입으로 모듈화되어 개발되었으며, 탈부착을 통해 목적형 및 지속적 심박 측정이 가능하도록 구성하였다. 목적형 심박측정 기기는 NFC(Near Field Communication), 심박 센서를 내장하고 필요시에 스마트 폰 태깅을 통해 심박 측정이 가능하게 하는 의류에 부착된 타입으로 개발되었으며, 지속형 심박 측정 기기는 BLE(Bluetooth Low Energy) 통신 및 배터리를 내장하여 목적형 기기와 결합을 통해 통신 및 전원을 지원, 지속적으로 심박 측정이 가능한 시스템으로 구성되었다. 심박 측정을 위한 섬유 전극은 은사 기반의 편물 전극으로, 심박 측정에 용이하도록 대흉근 아래에 위치하도록 디자인되었으며, 목적형 심박측정 기기가 전극과 연결되도록 구성되었다. 연동되는 어플리케이션은 사용자 경험요소, 주요기능 및 사용편의성 등을 고려하여 개발되었으며, 사용성 향상을 위하여 스마트 폰 태깅을 통해 자동 동기화가 되도록 개발되었다. 본 연구에서 개발된 심박측정 스마트 의류 시스템의 심박측정 정확도를 평가하기 위하여, 10명의 20대 남성 피험자를 대상으로 2단계의 실험을 설계하고 진행하였으며, POLAR RS800을 통해 측정되는 신호를 기준 심박으로 비교·분석하였다. 그 결과, 목적형 스마트 의류 시스템의 평균 심박수는 85.37, 기준 기기 심박수는 87.03으로 96.73%의 정확도를 갖는 것으로 분석되었으며, T 값 -1.892 (p=.091)로 두 신호간의 유의한 차이는 없는 것으로 분석되었다. 지속형 스마트 의류 시스템의 평균 심박수는 86.00, 기준 기기 심박수는 86.97로 97.16%의 정확도를 보였으며, T 값 -1.089(p=0.304)로 두 시스템 간의 측정 차이는 없는 것으로 분석되었다. 본 연구에서는 사용자의 목적에 따라 심박측정이 가능한 모듈형 스마트 의류 시스템을 개발하고 검증한 것에 의의가 있다. 또한, 모듈화 된 심박측정 의류 시스템 개발로 불필요한 기능으로 인한 가격 상승을 줄임으로써 이원화된 상품 기획의 가능성을 제시하였다.

하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례 (Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report)

  • 김민정;허중보;정창모;윤미정;이소현;조용범
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.71-79
    • /
    • 2022
  • 부분 무치악 환자에 있어 심한 골소실으로 인해 치관부 수직높이가 과도해질 우려가 있는 경우에는 임플란트 식립 후 고정성 보철물로 수복시 임플란트 주변 골의 응력 증가 및 나사 풀림이 발생할 가능성이 증가할 수 있다. 이러한 경우에 milled bar 및 가철성 보철물로 수복할 수 있는데, milled bar는 단일 임플란트 간의 일차적인 스플린팅 효과와 안정성을 부여할 수 있다. 또한 milled bar 사용 시 Advanced Dental Device-Treatment Of Choice(ADD-TOC), 자석 부착장치 같은 부가적인 부착장치 사용을 통해 임플란트 피개의치의 추가 유지력을 부여할 수 있다. 본 증례의 환자는 하악 좌측 구치부 평활근육종으로 인한 절제술 후 심한 골소실 및 다수 치아를 상실한 부분 무치악 환자로 장기간의 하악 구치부 상실로 인한 대합치는 정출된 상태였다. 상악 좌측 대구치는 교정적 압하를 통해 교합평면을 회복하였고, 하악 좌측 대구치 부위는 임플란트 식립 후 milled bar에 부가적인 부착장치인 ADD-TOC, 자석 부가장치를 이용하여 임플란트 피개의치로 수복하였다. 이를 통해 장기적으로 기능적, 심미적인 만족할 만한 결과를 얻었기에 보고하는 바이다.

UV-IR 복합형 화재감지장치 개발 (The Development of UV-IR Combination Flame Detector)

  • 이복영;권오승;정창기;박상태
    • 한국안전학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

메모리 반도체 회로 손상의 예방을 위한 패키지 구조 개선에 관한 연구 (Appropriate Package Structure to Improve Reliability of IC Pattern in Memory Devices)

  • 이성민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.32-35
    • /
    • 2002
  • The work focuses on the development of a Cu lead-frame with a single-sided adhesive tape for cost reduction and reliability improvement of LOC (lead on chip) package products, which are widely used for the plastic-encapsulation of memory chips. Most of memory chips are assembled by the LOC packaging process where the top surface of the chip is directly attached to the area of the lead-frame with a double-sided adhesive tape. However, since the lower adhesive layer of the double-sided adhesive tape reveals the disparity in the coefficient of thermal expansion from the silicon chip by more than 20 times, it often causes thermal displacement-induced damage of the IC pattern on the active chip surface during the reliability test. So, in order to solve these problems, in the resent work, the double-sided adhesive tape is replaced by a single-sided adhesive tape. The single-sided adhesive tape does net include the lower adhesive layer but instead, uses adhesive materials, which are filled in clear holes of the base film, just for the attachment of the lead-frame to the top surface of the memory chip. Since thermal expansion of the adhesive materials can be accommodated by the base film, memory product packaged using the lead-flame with the single-sided adhesive tape is shown to have much improved reliability. Author allied this invention to the Korea Patent Office for a patent (4-2000-00097-9).

  • PDF

영구자석바퀴를 이용한 벽면 이동로봇의 설계치침에 의한 이동체 개발 (Development of mobile vehicle designed by the guideline of wall-climbing mobile robot using permanent magnetic wheels)

  • 한승철;이화조;김은찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1676-1681
    • /
    • 2003
  • The attachment of mobile vehicle is necessary for the automated operation on the inclined or vertical walls of steel structures. Since the vehicle requires attaching devices additionally, its overall efficiency can be reduced by the devices. Therefore, external shapes of mobile vehicles have to be researched to give the effective movement on the vertical face. For the design of mobile vehicle, the guideline has been derived from the modeling of wall-climbing, so that the vehicle should have a specific external shape for vertical movement due to the gravitational force. Hence, some adequate arrangement of attaching device to the mobile vehicle has been presented for the effective movement. In the experiments with four permanent magnetic wheels, a plausible result was achieved as a vertical attaching force of 185.2(N), a friction force of 153.8(N) and a curvature radius of 1.4m. The mobile vehicle should be modified according to the proposed design guideline. and then it could be applied to a specific operation as an appropriate external shape. Also, Further research is recommended on an optimal posture and a moving method in a specific application. as the attaching force ortho vehicle can be affected by its posture.

  • PDF

Experimental investigation of magnetic-mount PZT-interface for impedance-based damage detection in steel girder connection

  • Ryu, Joo-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • 제4권3호
    • /
    • pp.237-253
    • /
    • 2017
  • Among various structural health monitoring technologies, impedance-based damage detection has been recognized as a promising tool for diagnosing critical members of civil structures. Since the piezoelectric transducers used in the impedance-based technique should be bonded to the surface of the structure using bonding layers (e.g., epoxy layer), it is hard to maintain the as-built condition of the bonding layers and to reconfigure the devices if needed. This study presents an experimental investigation by using magnetically attached PZT-interface for the impedance-based damage detection in bolted girder connections. Firstly, the principle of the impedance-based damage detection via the PZT-interface device is outlined. Secondly, a PZT-interface attachment method in which permanent magnets are used to replace the conventional bonding layers is proposed. Finally, the use of the magnetic attraction for the PZT-interface is experimentally evaluated via detecting the bolt-loosening events in a bolted girder connection. Also, the sensitivity of impedance signatures obtained from the PZT-interface is analyzed with regard to the interface's material.

유압 브레이커 메인바디의 충격 및 소음 저감을 위한 완충 장치에 대한 연구 (Damping Device for Hydraulic Breaker: Impact and Noise Reduction)

  • 조병진;한훈희;구정서
    • 한국기계가공학회지
    • /
    • 제17권4호
    • /
    • pp.113-122
    • /
    • 2018
  • A hydraulic breaker is an attachment of an excavator, and it crushes stones. Recently, research to reduce the impact and noise of breakers are ongoing. In this paper, a method to improve the upper, lower, and side dampers, which act as insulation for the attenuation of vibration during breaker operation, is studied through testing and simulation. To obtain the nonlinear material constants required for the simulation, the biaxial tensile test was performed with urethane, which is a material used for dampers. The existing parts and the improved parts were compared and evaluated using the LS-DYNA program. As a result, 50% of the equivalent stress was reduced in the bracket body of the hydraulic breaker, and the equivalent stress of the side damper was also decreased. We verified that the fatigue conditions were satisfied by performing a fatigue analysis.