• Title/Summary/Keyword: deviation ratio

Search Result 915, Processing Time 0.025 seconds

Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy (골(骨)스캔을 이용(利用)한 천장관절(薦腸關節)/천골섭취비(薦骨攝取比)의 정량적(定量的) 측정(測定))

  • Lee, Young-Yiul;Park, Seon-Yang;Lee, Myung-Chul;Choi, Sung-Jae;Cho, Bo-Youn;Choe, Kang-Won;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.63-70
    • /
    • 1982
  • To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio(SIS Ratio) by region of interest(ROI) method using $^{99m}Tc-methylene$ diphosphonate. The observed results were as follows: 1. Using ROI method, the SIS ratios for the control group of 65 persons were $1.05{\pm}0.08$(left) and $1.06{\pm}0.07$(right) which were narrower in range than those of slice method $(mean{\pm}S.D.)$. 2. The effects of age, gender and laterality on SIS ratio were not significant. 3. In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4. In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who had no evidence of sacroiliitis clinically was within normal limit. 5. In 6 patients with ankylosing spondylitis in both sacroiliac joints, 4 whose pelvis A-P Xray findings showed severe sclerotic change of sacroiliac joints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6. 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded that quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  • PDF

Comparison Study of Dose Rate and Physical Parameters in Low and High Dose Rate Intracavitary Radiation Systems for Carcinoma of the Uterne Cervix. (자궁경부암 강내 방사선조사에 있어서 고 및 저 선량율방법에 의한 선량율 비교 고찰)

  • Yang, Chil-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.70-78
    • /
    • 1985
  • The intrauterine irradiation is essential to achieve adequate tumor dose to centeral tumor mass in radio therapy for uterine malignancy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The comparison study of currently using 2 systems was undertaken. The simulation films and medical records of 135 patients who was treated with intrauterine irradiation at one of general hospitals in Busan and Seoul between Jan. 1983 and June 1983, were critically analized and physical parameters of low dose rate system and remote controlled high dose rate system were measured. The physical parameters include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids, the radiation dose ratio to rectum and bladder to reference point A. Followings were summary of study results: 1. In distances between lateral walls of vaginal fornices the low dose rate system showed wide distribution and relatively larger distances. In low dose rate system 5.0-5.9 cm was $55.89\%$ 6.0-6.9 cm: $23.53\%$, 4.0-4.9cm: $10.29\%$, 3.0-3.9cm: $10.29\%$, and in high dose rate system 5.0-5.9cm was $80.59\%$, 4.0-4.9cm: $17.91\%$, $6.0\~6.9\;cm:\;1.5\%$. 2. In lateral angulation of tandem to body axis, the low does system revealed mid position (the position along body axis) $64.7\%$, Lt. deviation $19.13\%$ and Rt. deviation $16.17\%$. However the high dose rate system revealed mid position $49.26\%$ Lt. deviation $40.29\%$ and Rt. deviation $10.45\%$. 3. In longitudinal angulation of tandem to body axis the mid position was $11.77\%$ and anterior angulation $88.23\%$ in low dose rate system but in high dose rate system the mid position was $1.56\%$ and anterior angulation $98.44\%$. 4. Down ward displacement of ovoids below external os was only $2.94\%$ in low dose rate system and $67.69\%$ in high dose rate system. 5. The radiation dose ration to rectum to reference point A was $102.70\%$ in high dose rate system and $70.09\%$ in low dose rate system. The dose ratio to bladder to reference point A was $78.14\%$ in high dose rate system and $75.32\%$ in low dose rate system.

  • PDF

Analysis of the Process Capability Index According to the Sample Size of Multi-Measurement (다측정 표본크기에 대한 공정능력지수 분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.151-157
    • /
    • 2019
  • This study is about the process capability index (PCI). In this study, we introduce several indices including the index $C_{PR}$ and present the characteristics of the $C_{PR}$ as well as its validity. The difference between the other indices and the $C_{PR}$ is the way we use to estimate the standard deviation. Calculating the index, most indices use sample standard deviation while the index $C_{PR}$ uses range R. The sample standard deviation is generally a better estimator than the range R. But in the case of the panel process, the $C_{PR}$ has more consistency than the other indices at the point of non-conforming ratio which is an important term in quality control. The reason why the $C_{PR}$ using the range has better consistency is explained by introducing the concept of 'flatness ratio'. At least one million cells are present in one panel, so we can't inspect all of them. In estimating the PCI, it is necessary to consider the inspection cost together with the consistency. Even though we want smaller sample size at the point of inspection cost, the small sample size makes the PCI unreliable. There is 'trade off' between the inspection cost and the accuracy of the PCI. Therefore, we should obtain as large a sample size as possible under the allowed inspection cost. In order for $C_{PR}$ to be used throughout the industry, it is necessary to analyze the characteristics of the $C_{PR}$. Because the $C_{PR}$ is a kind of index including subgroup concept, the analysis should be done at the point of sample size of the subgroup. We present numerical analysis results of $C_{PR}$ by the data from the random number generating method. In this study, we also show the difference between the $C_{PR}$ using the range and the $C_P$ which is a representative index using the sample standard deviation. Regression analysis was used for the numerical analysis of the sample data. In addition, residual analysis and equal variance analysis was also conducted.

A Study on Characteristics of Sn-37Pb and Sn-4.0Ag-0.5Cu Solder Joints as Various A:V Ratio (A:V Ratio 변화에 따른 Sn-37Pb, Sn-4.0Ag-0.5Cu Solder 접합부의 특성 연구)

  • Han, Hyun-Joo;Lim, Seok-Jun;Moon, Jung-Tak;Lee, Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.67-73
    • /
    • 2001
  • To investigate the relationships of solder joint characteristics with solder composition and A:V ratio (solder volume per pad area), Sn-37Pb and Sn-4.0Ag-0.5Cu solder balls with 330, 400, 450 and $457{\mu}{\textrm}{m}$ size were reflowed on same substrate. Sn-37Pb and Sn-4.0Ag-0.5Cu was reflowed at $220^{\circ}C$ and $240^{\circ}C$ respectively by IR-type soldering machine. As a result of reflowed solder- ball diameter(D) and height(H) measurement, D/H was decreased with solder ball size increment in range of 330~450 ${\mu}{\textrm}{m}$. But, D/H was increased in the solder joint for 457 ${\mu}{\textrm}{m}$ size, it was caused possibly by decrement of solder ball height increment compared with solder volume increment. As a result of shear and pull test, joint strength with A:V ratio was high. Joint strength of Sn-4.0Ag-0.5Cu was higher than Sn-37Pb. However, Sn-37Pb had more stable solder joint of small standard deviation. A thick and clean scallop type Ni-Cu-Sn intermetallic compound layer was formed in high A:V ratio and Sn-4.0Ag-0.5Cu solder joint interface.

  • PDF

Analyses of Soil Cadmium and Copper Contents on a Region of Burgundy in France

  • Kim, Sangdeog A.;Alain Bermond;Denis Baize
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.20 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The aim of present research was to know Cd availability. As a first report of this work, we present some results of analysing soil Cd and Cu contents on a part of Burgundy in France. Soil samples were collected from surface-ploughed layer in fields across the southern part of the Yonne district, Burgundy, France. From the first extractable Cd content on a ratio (soil : EDTA =1:10), the soil Cd values on Carixien soil series decreased to a-third or to a-fourth of those Cd values on a lower ratio (soil : EDTA = 15). While the extractable Cd of the soil samples on Sols marron soil series decreased in a smaller extent. The changes of mixing ratio from 150 (soil : EDTA) to 1:10 and to 1:5 (soil : EDTA) had decreased the extractable Cu contents. But the range of the decrease was not so large as that of Cd contents. Soils on some soil series were a half (Carixien) or two-thirds level (Dombrien, Aubes) when comparing the extractable Cu content on 1:5 ratio to the content on 150 ratio. The absorbance for Cu analyses of soils on Carixien, Terres noires, Sols marron soil series varied in larger extent (expressed on standard deviation for 6 values) than that of soils on Dombrien, Aubes soil series.

  • PDF

A Study on Bead Height Control of GMAW by Short Circuit Time Ratio (단락시간비를 이용한 GMAW의 비드 높이 제어에 관한 연구)

  • 감병오;조상명;김상봉
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.53-59
    • /
    • 2002
  • This paper shows the experimental results controlling the height of surface and back bead in GMAW by analyzing the unexpected gaps between base metals produced in welding and by controlling welding velocity due to the variation of the gap between base metals in thin-plate welding. The back bead behavior and burn-through in I-type butt joint $CO_2$ welding of thin mild steel are analyzed in the views of short circuit time ratio and short circuit frequency. It is shown through experimental consideration that the short circuit time ratio method is more reasonable than the short circuit frequency method in analyzing the formulation of back bead under changing the gap between base metals. Based on the these results, welding manipulator is designed so as to satisfy the bead height control in real time by measuring the short circuit time ratio. To show the effectiveness of the developed bead formulation control system, the experiment is implemented under two welding conditions such as increasing gap from 0mm to 0.8mm and gradually increasing gap from 0mm to 1.2mm. The experimental results show that the bead formulation can be controlled uniformly in spite of the variation of the gap between base metals.

Development of Korean Standard Vertical Design Spectrum Based on the Domestic and Overseas Intra-plate Earthquake Records (국내외 판내부 지진기록을 이용한 한국 표준수직설계스펙트럼의 개발)

  • Kim, Jae Kwan;Kim, Jung Han;Lee, Jin Ho;Heo, Tae Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.413-424
    • /
    • 2016
  • The vertical design spectrum for Korea, which is known to belong to an intra-plate region, is developed from the ground motion records of the earthquakes occurred in Korea and overseas intra-plate regions. From the statistical analysis of the vertical response spectra, a mean plus one standard deviation spectrum in lognormal distribution is obtained. Regression analysis is performed on this curve to determine the shape of spectrum including transition periods. The developed design spectrum is valid for the estimation both spectral acceleration and displacement. The ratio of vertical to horizontal response spectrum for each record is calculated. Statistical analysis of the ratios rendered the vertical to horizontal ratio (V/H ratio). Subsequently the ratio between the peak vertical ground acceleration to the horizontal one is obtained.

Risk and Return of Islamic and Conventional Indices on the Indonesia Stock Exchange

  • SURYADI, Suryadi;ENDRI, Endri;YASID, Mukhamad
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.23-30
    • /
    • 2021
  • The purpose of this study is to compare the level of risk and return of Islamic stocks in the Jakarta Islamic Index (JII) with conventional stocks on the IDX30 in the period from January 2017 to July 2019. The Sharpe ratio method is used to calculate risk and stock returns. The performance of the stock portfolio is measured by comparing the risk premium portfolio with the portfolio risk that is expressed as a standard deviation of the total risk. This study uses secondary data collected by the Indonesia Stock Exchange (IDX), which provides the names of stock issuers included in the JII and IDX30 indices along with their montly closing price. The results of the descriptive analysis show that the JII Sharpe ratio index from January 2017 to July 2019 is from the minimum range of -0.28820 to a maximum range of 0.05622, while the IDX30 Sharpe ratio index from January 2017 to July 2019 is from the minimum range of -0.09290 to the maximum range of 0.17436. The results of inferential analysis using a different test show that there is a significant difference between the Sharpe ratio JII and IDX30 in measuring the performance of the stock portfolio.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

A Study of Establishment of the Standard Sizes for the High School Girls (II) (한국 여고생의 표준치수 설정을 위한 연구 (II))

  • 손원교
    • Journal of the Korean Home Economics Association
    • /
    • v.12 no.2
    • /
    • pp.621-631
    • /
    • 1974
  • The objective of the study was to obtain standard sizes of body of the high school girls for designing clothes and developing pattern grading of clothes. In 1972, 342 students, selected by the stratified cluster random sampling method, at three high schools in Seoul were measured on forty-one items by the R. Martin method. Statistical techniques of mean, standard deviation, coefficient variable, maximum and minimum, range, t-test were utilized to analyze the data. The findings of the study were as follows ; 1. No differences were found among the age groups in the all measured variables. 2. Stature, bust girth, hip girth, acromion width, posterior waist girth/stature ratio of the high school girls were significantly smaller than those sizes of adult women. This result implies that those sizes will be increased as the students grow up. But upper arm girth, upper arm girth/bust girth ratio, and thigh girth/bust girth ratio were bigger than those sizes of adult women. Waist girth, thigh girth, total head height/stature ratio, acromion width/stature ratio, and foot length/stature ratio were nearly similiar to those of adult women. 3. According to the result of t-test, waist breadth, spinailiaca anterior height/stature ratio, thigh girth/bust girth ratio, and thigh/hip girth ratio of the 15 year old group were significantly different from those of the 16 year old group at the level of 0.05. Bust girth, weight, foot breadth, posterior croth length, and cervical height/stature ratio of the 16 year old group were significantly different from those of the 17 year old group at the level of 0.01. Hip girth, upper arm girth, waist breadth/stature ratio, and neck base girth/bust girth ratio of the 16 year old group were significantly different from those of the 17 year old group at the level of 0.05.

  • PDF