• Title/Summary/Keyword: deviation correction

Search Result 274, Processing Time 0.024 seconds

A Study on Course Correction Performance Expectation & Algorithm Implementation of 1D CCM (1D CCM 탄도수정 성능예측 및 알고리즘 구현 연구)

  • Kim, Ki-Pyo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-13
    • /
    • 2007
  • The trajectory of an current artillery munition is subject to a variety of different error sources resulting in more or less big deviation from the nominal predicted flight path. The 1D CCM(Course Correction Munition) has appeared to solve this problem and the mechanism of 1D CCM is a simple and low cost one using the influence of drag to range behavior of an artillery munition. In the paper 1D CCM concept has been simulated using wind tunnel experiment results of the specified Korean munition with CCF(Course Correction Fuze) and calculated the performance of its rang error reduction. From the simulated results it can be numerically explained that the possibility of adaptation of 1D CCM concept to Korean artillery munitions.

Fuel Consumption Rate Calculation Equation and its Application at fewer Boiler (화력발전소 보일러 연료소비량 계산 및 정확성 검증)

  • Jang, Seok-Won;Kim, Jae-Hoo
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.147-152
    • /
    • 2005
  • Calculation equations of fired fuel comsumption rating at boiler can lead from combustion anal-ysis and boiler heat balance using mass & energy conservations. By comparing calculation equation results with those of measurement, we can confirm the deviation of fuel consumption rate, and correction rate, and correction degree, and can also establish the proven technology to apply the equation at the site. We applied fuel rate equation to the operating power plant and recorded $2.4\%\;&\;1.5\%$ of deviation at each coal and oil fired boilers. This range of deviation is regarded as trustable to apply the fuel consumption equation to the actual site.

Performance Evaluation System for Tow-Channel Ring-Core Flux-Gate Compass (2-체널 링-코어 프럭스-게이트 콤파스의 성능평가 시스템 개발)

  • 임정빈;김봉석
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.13-19
    • /
    • 2002
  • Design and implementation methodologies on the performance evaluation system of two-channel ring-core Flux-Gate Compass (FG-Compass) are described, with evaluation procedures and methods based on the polynomial regression models. Performance evaluation system is consists of a step motor driving unit, a bearing transmitting unit and, evaluation programs using polynomial regression formulae. Through performance evaluation tests, total residual deviation tests, total residual deviation of $\pm$4$^{\circ}$ and eigen residual deviation of $\pm$2$^{\circ}$ are obtained from the FG-Compass. The result is more accurate values than the typical FG-Compass with eigen residual deviation of $\pm$4$^{\circ}$ and is provide a possibility to develop a high performance FG-Compass. In addition, the design methodology of a smart FG-Compass with the self estimation and correction of residual deviations is also discussed.

  • PDF

Evaluation of improvement effect on the spatial-temporal correction of several reference evapotranspiration methods (기준증발산량 산정방법들의 시공간적 보정에 대한 개선효과 평가)

  • Kim, Chul-Gyum;Lee, Jeongwoo;Lee, Jeong Eun;Kim, Hyeonjun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.9
    • /
    • pp.701-715
    • /
    • 2020
  • This study compared several reference evapotranspiration estimated using eight methods such as FAO-56 Penman-Monteith (FAO PM), Hamon, Hansen, Hargreaves-Samani, Jensen-Haise, Makkink, Priestley-Taylor, and Thornthwaite. In addition, by analyzing the monthly deviations of the results by the FAO PM and the remaining seven methods, monthly optimized correction coefficients were derived and the improvement effect was evaluated. These methods were applied to 73 automated synoptic observation system (ASOS) stations of the Korea Meteorological Administration, where the climatological data are available at least 20 years. As a result of evaluating the reference evapotranspiration by applying the default coefficients of each method, a large fluctuation happened depending on the method, and the Hansen method was relatively similar to FAO PM. However, the Hamon and Jensen-Haise methods showed more large values than other methods in summer, and the deviation from FAO PM method was also large significantly. When comparing based on the region, the comparison with FAO PM method provided that the reference evapotranspiration estimated by other methods was overestimated in most regions except for eastern coastal areas. Based on the deviation from the FAO PM method, the monthly correction coefficients were derived for each station. The monthly deviation average that ranged from -46 mm to +88 mm before correction was improved to -11 mm to +1 mm after correction, and the annual average deviation was also significantly reduced by correction from -393 mm to +354 mm (before correction) to -33 mm to +9 mm (after correction). In particular, Hamon, Hargreaves-Samani, and Thornthwaite methods using only temperature data also produced results that were not significantly different from FAO PM after correction. It can be also useful for forecasting long-term reference evapotranspiration using temperature data in climate change scenarios or predicting evapotranspiration using monthly or seasonal temperature forecasted values.

Acquisition Method for Deviation Coefficients Band B and C at a Single Bearing (단일 침로에서의 자차 계수 B 와 C 획득방법)

  • Yim Jeong-Bin;Sim Yeong-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.23-32
    • /
    • 2004
  • This paper describes a new estimation method for deviation coefficients, B and C. using only measured single deviation at a fixed compass bearing. At first, some problems in the deviation synthesis with only two coefficients, B and C, are discussed using observed deviation values measured in the four USS warships. Then, acquisition theories and procedures to obtain optimal coefficients, B and C, are expanded and then the efficiencies of the proposed prediction method are evaluated. As results from evaluations, it is shown that the approximated coefficients, B and C, can give optimal approximation to observed single deviation.

  • PDF

Surgical correction of septal deviation after Le Fort I osteotomy

  • Shin, Young-Min;Lee, Sung-Tak;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.21.1-21.6
    • /
    • 2016
  • Background: The Le Fort I osteotomy is one of the most widely used and useful procedure to correct the dentofacial deformities of the midface. The changes of the maxilla position affect to overlying soft tissue including the nasal structure. Postoperative nasal septum deviation is a rare and unpredicted outcome after the surgery. There are only a few reports reporting the management of this complication. Case Presentation: In our department, three cases of the postoperative nasal septum deviation after the Le Fort I osteotomy had been experienced. Via limited intraoral circumvestibular incision, anterior maxilla, the nasal floor, and the anterior aspect of the septum were exposed. The cartilaginous part of the nasal septum was resected and repositioned to the midline and the anterior nasal spine was recontoured. Alar cinch suture performed again to prevent the sides of nostrils from flaring outwards. After the procedure, nasal septum deviation was corrected and the esthetic outcomes were favorable. Conclusion: Careful extubation, intraoperative management of nasal septum, and meticulous examination of preexisting nasal septum deviation is important to avoid postoperative nasal septum deviation. If it existed after the maxillary osteotomy, septum repositioning technique of the current report can successfully correct the postoperative septal deviation.

Septal deviation correction methods and surgical considerations in turbinoplasty

  • Kang, Eun Taek
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.522-527
    • /
    • 2020
  • Nasal septoplasty is often required to correct a cosmetic deformity, which is a common reason for patients to present to a plastic surgeon. If nasal septoplasty is insufficient, a residual deformity or nasal obstruction may remain after surgery. Even if the nasal septum is corrected to an appropriate position, nasal congestion could be exacerbated if the turbinate on the other side is not also corrected. Therefore, appropriate treatment is required based on the condition of the turbinates. Herein, we survey recent trends in treatment and review previous research papers on turbinoplasty procedures that can be performed alongside nasal septoplasty.

CFD ANALYSIS OF SUBSONIC AIRFOIL WIND TUNNEL TEST (아음속 익형 풍동시험 전산해석)

  • Kim, C.W.;Lee, Y.G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.167-170
    • /
    • 2007
  • In the present paper, wall correction method is reviewed and applied to the numerical experimental results obtained at the wind tunnel condition. The corrected lift coefficient agrees well with the reference data generated from the grid having very far boundary. However the corrected drag coefficient presents some deviation from the reference data.

  • PDF

Statistical Atmospheric Correction of Lake Surface Temperature from Landsat Thermal Images

  • Han, Hyang-Sun;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.418-421
    • /
    • 2005
  • In this study, we analyzed surface temperature of lakes in the Han River system, using Landsat-5 and -7 time-series images. Surface temperature was extracted using NASA equation and compared with in situ 10m-depth temperature in Lake Soyang and surface temperature on five other dam lakes downstream. The 24 images out of 29 showed standard deviation of temperature difference less than $2^{\circ}C$, to which a novel statistical atmospheric correction could be applied. The correlation coefficients were 0.950 at Lake Soyang and 0.979-0.997 at the other lakes after atmospheric correction.

  • PDF

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF