• Title/Summary/Keyword: detention

Search Result 303, Processing Time 0.024 seconds

Optimal Sensor Placement for Rapid Detecting in Chemical Leak Accident (화학물질의 누출에서 빠른 감지를 위한 센서 배치 최적화)

  • Cho, Jaehoon;Kim, Hyunseung;Kim, Taeok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.66-71
    • /
    • 2016
  • Nowadays, a number of sensors which are placed in industrial complex are monitoring areas involving chemical leak and other faults. However, even in the presence of the sensors, chemical leaks, sometimes involving huge amount of chemicals, continuously led to big losses in the industrial complex. In most industries, sensor installation has been performed using past experience or using senor manufacturers' guideline; which leads to poor performance of the installed sensor grid. Therefore, we investigate an optimal placement methodology of point sensors for rapid detention and response when chemical leaks happen. This research suggests a generalized formulation suitable for the optimized decision making of minimizing number of sensors to be placed and increasing the fraction of covered scenarios under assumption of negligible effect of other structures. The proposed method has been verified for suitable performance for simple leak scenario simulations, by achieving the safety objectives and guaranteeing safe process operations.

Establishment and Characterization of the Fibroblast Line from Silkie Bantam

  • Li, L.F.;Guan, W.J.;Li, H.;Bai, X.J.;Ma, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.4
    • /
    • pp.492-499
    • /
    • 2009
  • A Silkie Bantam embryo fibroblast line (named SBF59 line) was successfully established by using direct explant culture and cryopreservation techniques. Cell morphology, viability, dynamic growth and contamination were tested and the karyotype and levels of isoenzymes of lactic dehydrogenase and malic dehydrogenase were analyzed. Four kinds of fluorescent protein extrogenes, including $pEGFP-N_3$, $pECFP-N_1$, $pEYFP-N_1$ and $pDsRed1-N_1$ were transfected into the cells. The results showed that the cells were healthy and possessed a fibrous structure without a change in morphology. The average viability of the cells was 96% before freezing and 90.5% after thawing. The growth curve appeared as typical "S" shape and the cell growth passed through a detention phase, a logarithmic phase and a platform phase; the estimated population doubling time (PDT) was 38.5 h; assays for the presence of bacteria, fungi, viruses and mycoplasmas were negative; the cell line showed no cross contamination when assessed by isoenzyme analysis; the chromosome number was 2n = 78 on more than 88% of occasions; four kinds of fluorescent protein extro-genes appeared to be expressed effectively with a high transfection efficiency between 18.3% and 42.3%. The cell line met the required quality control standard. It not only preserves the genetic resources of the important Silkie Bantam at the cellular level but also provides valuable materials for genomic, post-genomic, somatic cell cloning research and other applications.

Mixture treatment of food waste and sewage sludge using pilot scale anaerobic digester (Pilot scale 2단 혐기성 소화조를 이용한 음식물쓰레기와 하수슬러지의 혼합처리)

  • Park, Nam-bae;Lee, Heon-Mo;Lee, Byung-Heon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 1999
  • Recently, the treatment of that wastes according to increase of food waste has been a great problem of modern society for long time. This study was aimed to evaluate possibility for food waste and sewage sludge mixture treatment using pilot scale two-phase anaerobic digester. Pilot scale two-phase anaerobic digestion system was performanced at 1 : 9 mixture ratio of food waste and sewage sludge infield. The detention time of digester was 20days. The average COD and VS removal efficiencies in organic loading rate $3.03kg\;TCOD/m^3-day$ were 57.7 and 47.7%, and the gas production rate and methane content were $0.4m^3/kg$ VS-day and 65.3%, respectively. TS, VS and VS/TS(%) of mixing tank were 4.44%, 2.59% and 58.34%, respectively and TS. VS and VS/TS(%) of digester in steady state were 3.32%, 1.39% and 41.90%, respectively, Through this study. it was possible to accomplish effective mixture treatment of the sewage sludge and food waste.

  • PDF

Intelligent Controller for Constant Control of Residual Chlorine in Water Treatment Process (정수장 잔류염소 일정제어를 위한 지능형 제어기 개발)

  • Lee, Ho-Hyun;Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • In this study, chlorine modeling technique based on fuzzy system is proposed to reduce the carcinogenic substance and decide the optimal chlorine injection rate, which is affected by chlorine evaporation rate in sedimentation basin according to detention time, weather and water quality. The additional chlorine meter is installed in the inlet part of sedimentation to reduce the feedback time and implement cascade control, which leads to maintaining the residual chlorine concentration decided by fuzzy rule. It helps to take a preemptive action about long time delay, the characteristics of the disinfection process, and reduce the variation of residual chlorine rate by 7.3 times and the chlorine consumption by 40,000 dollars. It made a significant contribution to supply hygienically safe drinking water.

A Study on Targer Factor Value of Port State Control Inspection Using Absolute Measurement (절대평가법을 이용한 항만국통제 점검 표적점수 평가에 관한 연구)

  • Jang, Woon-Jae
    • Journal of Navigation and Port Research
    • /
    • v.34 no.6
    • /
    • pp.471-477
    • /
    • 2010
  • In recently, IMO consider including an marine casualty factor when Port State Control Inspection evaluate.. This paper proposes an evaluation to Target Factor Values of Port State Control Inspections(PSCITFV) using absolute measurement. To this solve, therefore, this paper used the absolute measurement which is informed compensate the defect and the more rational and objective methode, checked the effectiveness to compare an result with absolute measurement and PSCITFV of Tokyo MOU using Wilcoxson test. Finally, rate change of PSC was investigated by an experiment which changed the values of evaluation factors. As a result, it was evaluation factors of high rate change that was detention, ship's age, casualty factors. Therefore, this factors have to a priority management to do for prevent of PSC.

Estimation of the Stormwater Impoundments Volume Dependent on the Durations of Design Rainfall (계획강우의 지속기간에 따른 저류지용량의 산정)

  • Yun, Yeo-Jin;Lee, Jae-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.415-426
    • /
    • 2001
  • After Disaster Impact Assessment(DIA) Program was particed, the wide variety of hydrological data are estimated by introducing the concept of critical storm duration to calculate the stormwater impoundments as the alternative of increasing runoff due to many developments. Critical storm duration is varied by a lot of hydraulic structures, drainage characteristics, temporal distribution of design rainfall, return period, and runoff models. In this study the methods of estimating the proper volume to design the stormwater impoundments are proposed to determine the required volume by comparing and analyzing the maximum stormwater impoundments in accordance with the impoundment volume and rainfall duration by using the concept of storage ratio presented in the existing studies. The methods of determining the critical storm duration of design rainfall which cause the maximum load from the runoff hydrograph will be studied as analyzing rainfall-runoff using the various runoff models and observed data.

  • PDF

Post-Chlorination Process Control based on Flow Prediction by Time Series Neural Network in Water Treatment Plant

  • Lee, HoHyun;Shin, GangWook;Hong, SungTaek;Choi, JongWoong;Chun, MyungGeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.197-207
    • /
    • 2016
  • It is very important to maintain a constant chlorine concentration in the post chlorination process, which is the final step in the water treatment process (hereafter WTP) before servicing water to citizens. Even though a flow meter between the filtration basin and clear well must be installed for the post chlorination process, it is not easy to install owing to poor installation conditions. In such a case, a raw water flow meter has been used as an alternative and has led to dosage errors due to detention time. Therefore, the inlet flow to the clear well is estimated by a time series neural network for the plant without a measurement value, a new residual chlorine meter is installed in the inlet of the clear well to decrease the control period, and the proposed modeling and controller to analyze the chlorine concentration change in the well is a neuro fuzzy algorithm and cascade method. The proposed algorithm led to post chlorination and chlorination improvements of 1.75 times and 1.96 times respectively when it was applied to an operating WTP. As a result, a hygienically safer drinking water is supplied with preemptive response for the time delay and inherent characteristics of the disinfection process.

A Preliminary Study on Assessment of Urban Parks and Green Zones of Ecological Attributes and Responsiveness to Climate Change (도시공원녹지의 생태성 및 기후변화 대응성 평가 기초 연구)

  • Sung, Hyun-Chan;Hwang, So-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.3
    • /
    • pp.107-117
    • /
    • 2013
  • Problems in regard of ecological stability of urban ecosystem ensue from climate change and urbanization. Particularly, urban ecological conditions are deteriorating both quantitatively and qualitatively to a great extent. The present study aims to assess the current condition of selected sites (i. e. urban green zones and parks) in terms of preset assessment components; to find out problems and relevant solutions to improve the quality and quantity of parks and green zones; and ultimately to suggest some measures applicable to coping with climate change as well as to securing the ecological attributes of urban green zones and parks. According to the findings of this study, from quantitative perspectives, ecological attributes and responsiveness to climate change are high on account of the large natural-soil area(80%). By contrast, from qualitative perspectives including the planting structure (1 layer: 47%), the percentage of bush area(17%), the connectivity with surrounding green zones (independent types: 44%), the wind paths considered (5.6%), the tree species with high carbon absorption rates (20%), water cycles (17%), energy (8%) and carbon storage capacities(61%), ecological attributes and responsiveness to climate change were found very low. These findings suggest that the ecological values of urban parks and green zones should be improved in the future by conserving their original forms, securing natural-soil grounds and employing multi-layered planting structures and water bodies, and that responsiveness to climate change should be enhanced by planting tree species with high carbon storage capacities and obtaining detention ponds. In sum, robust efforts should be exerted in the initial planning stages, and sustained, to apply the methodology of green-zone development along with securing ecological attributes and responsiveness to climate change.

A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed (BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가)

  • Yoon, Chun-Gyeong;Shin, Ah-Hyun;Jung, Kwang-Wook;Jang, Jae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.

A Comparison and Analysis of Hydrologic Model for the design of Detention Pond in Urban Area (도시유역의 저류지 설계를 위한 수문모형 비교분석)

  • Lee, Jae-Joon;Kwak, Chang-Jae;Kim, Ho-Nyun;Lee, Sang-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1432-1436
    • /
    • 2007
  • 도시화로 인한 유출량의 증가 및 도달시간의 단축은 도시재해의 한 원인이 되고 있다. 이를 막기 위하여 도시 배수유역내에 저류지를 설치하여 첨두도달시간을 지연시키고 방류량은 하수관거의 통수능 이하로 조절하는 방안을 활용하고 있다. 저류지를 설계 운영함에 있어서 사용되는 수문모형은 일반적으로 계획모형, 설계모형 및 운영모형으로 분류되고 있다. 계획모형과 유사한 형태의 단순화된 설계모형이 있기 때문에 계획모형과 설계모형을 엄밀히 구별하기는 어려우나 일반적으로 저류지 용량 결정시 배수구역에 대한 홍수추적을 실시하여 구하는 경우를 설계모형으로 보고 있다. 본 연구에서는 재해영향평가서 22개소의 기 설계된 저류지를 분석대상으로 하여 여러 가지 저류지 계획모형과 설계모의모형(WinDETPOND 모형, BASINOPT 모형)의 적합성을 검토하고 분석대상 저류지와 비교분석을 실시하였다. 저류지 계획모형의 분석에서 on-line 저류지의 경우는 사다리꼴 형태 설계수문곡선을 채택하고 있는 이종태 등 모형의 결과가 대상 저류지의 실저류량과 가장 유사함을 보였고, off-line 저류지의 경우는 삼각형 형태 설계수문곡선을 채택하고 있는 Abt & Grigg 모형의 결과가 비교적 양호한 결과를 보이는 것으로 나타났다. on-line 실저류지 3개소의 저류지 계획모형과 설계모의모형의 결과를 비교분석결과 도시화 인자 ${\alpha}$의 연관성은 뚜렷이 나타나지는 않았지만, WinDETPOND 모형의 저류량은 BASINOPT 모형에 비해 실저류지와 유사한 결과를 나타내었다.

  • PDF