화재감지기의 오보 감소를 위한 구조 신뢰도 분석 (Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms)

  • 김주홍;임현교
    • 한국안전학회지
    • /
    • 제8권1호
    • /
    • pp.6-12
    • /
    • 1993
  • Now it is reported that there are many companies and factories which confront to the problem of false alarm in Automatic Fire Detecting System (AFDS). Though an AFDS is a high-priced and very important device in detecting a fire. the problem degrades the reliability and utility, eventually faith. of the system. This is a research concerned about the problem of false alarm of fire detectors in an AFDS. Structure of detectors was modeled up as a general K out-of n system. and reliability characteristics including false alarm rate and missed alarm rate, are derived from it. For decision of an optimal structure of detectors. preliminary analysis on various criteria is accomplished. It is concluded that appropriate modification of a detector with plural sensors may increase the system reliability and decrease the false alarm rate.

  • PDF

원격탐사자료의 放射값 補正 (Radiometric Corrections of Digital Remote Sensing Data)

  • 정성학
    • 대한원격탐사학회지
    • /
    • 제10권1호
    • /
    • pp.15-29
    • /
    • 1994
  • 원격탐사자료의 픽셀값 변이 중 (위성에 의하여) 주사되는 물체 또는 전경등의 자체에 의한 것이 아닌 기타 변이에 대해서는 핏셀의 방사값을 보정하게 된다. 이러한 핏셀값 변이의 원 인에 대해서는 감지방치의 성능차이 및 작동불량, 또는 대기에 의한 간섭효과등을 들 수 있다. 감 지장치들의 성능차에 의하여(원치 않는) 줄이 그어진 화상자료를, 그리고 작동불량으로 값이 零 (영)인 픽셀들을 얻게 되며, 또한 빛의 산란에 기인하는 대기의 편기등이 발생하게 되는 데, 이러 한 변이들에 대하여는 그 방사값을 보정한다. 본고에서는 이러한 방사값 보정법으로 일부 주요원 칙에 대하여 예제와 함께 고찰하였다.

A Study on the Germanium Radiation Detector Compensated by Gamma-ray Irradiation

  • Moon, P.S.
    • Nuclear Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.85-94
    • /
    • 1975
  • n형 Ge 결정체를 보상하기 위해 상온에서 $^{60}$Co 감마선으로 647 Mrad 조사하였다. 감마선으로 조사된 Ge 결정체로 Ge(${\gamma}$) 검출기를 제작하였다. Ge(${\gamma}$) 검출기의 검출기 특성은 얇은 Ge(Li) 검출기나 고순도 Ge 검출기와 비슷하였다. Ge(${\gamma}$) 검출기의 온도에 대한 안정도는 상온에서의 저장이 가능함을 보여 주었다.

  • PDF

국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구 (Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings)

  • 손봉세
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.533-538
    • /
    • 2014
  • 본 연구는 공동주택 전용 지능형 화재감지시스템개발을 위한 기초연구로서 공동주택에 설치하는 기존 자동화재탐지설비의 화재감지기 실태 및 성능개선대책에 필요한 기초 연구를 하였다. 공동주택 전용지능형 감지시스템의 개발에 필요한 기초자료를 분석하기 위하여 기존 감지기성능 및 유지관리 등의 문제점을 조사하였다. 이를 위하여 국내 외 주거공간에서 발생한 화재통계자료를 분석하였고 피난 및 소방 활동에 중요한 역할을 하는 감지기성능 실태를 연구하였다. 특히, 공동주택에 설치된 기존의 화재감지기는 세대별로 경계구역이 설정되어 있지 않으며, 대부분 열감지기로 설치되어 조기에 화재를 감지할 수 없는 시스템으로 되어 있었다. 또한 세대별 설치된 감지기는 평상시에 정상작동 여부를 주거공간의 외부에서 점검할 수 없는 문제점이 있는 것으로 조사되었다. 따라서 본 연구에서는 이러한 문제점을 개선하기 위한 방안으로 기존의 열감지기보다는 초기 감지능력이 있는 연기감지기 또는 열 연기복합형 감지기, 단독형 연기감지기의 설치 및 공동주택 전용의 감지시스템을 개발하여 설치하는 것이 필요하다.

Qualification for Impedance-based Rain Detectors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong;Kim, Yong-Gyoo
    • 센서학회지
    • /
    • 제26권3호
    • /
    • pp.149-154
    • /
    • 2017
  • Detection of rain is one of the essential weather factors that are monitored by automatic weather stations in Korea. In this work, we studied the operation standards required for impedance-based rain detectors in terms of surface temperature and sensitivity, in an effort to establish a qualification procedure for rain detectors. The surface temperature of rain detectors was measured at varying air temperatures from $-30^{\circ}C$ to $20^{\circ}C$, considering the hypothetical presence and absence of rain/snow. In addition, the sensitivity of rain detectors was studied generating artificial raindrops of regular size. The sensitivity was evaluated in terms of the critical number of droplets that triggers the activation of the rain detector. We found that the sensitivity is affected by stationary, horizontal, and vertical droplet deposition methods. The critical number of droplets for the stationary deposition is higher than that for both horizontal and vertical depositions, which provides the maximum limit of droplets required to activate the detector. Based on our experiments considering surface temperature measurements and sensitivity tests, we suggest a revised version of surface temperature and sensitivity requirements for the qualification of impedance-based rain detectors.

2-D OCDMA LAN에서의 검출기와 간섭 모델의 성능에 대한 비교 연구 (A Study on Detectors and Interference Models for 2-D OCDMA Networks)

  • 윤용철;최진우;성원진
    • 한국통신학회논문지
    • /
    • 제28권4B호
    • /
    • pp.245-256
    • /
    • 2003
  • 2-D OCDMA는 근거리 광통신망의 구현을 위한 유력한 기술적 해법으로 고려되고 있으며, 다양한 2-D OCMA 기법/기술에 대한 많은 연구가 이루어지고 있다. 본 논문에서는 단극부호를 사용하는 2D OCDA 통신망의 성능분석을 위한 새로운 다중접속 간섭모델을 제안하고 이 간섭모델을 기초로 하는 최대공산검출기를 유도한다. 또한, 이들 최대공산검출기와 기존에 제안된 보다 단순한 구조를 갖는 검출기의 검출성능을 컴퓨터 모의실험을 통해 비교한다. 상대적으로 복잡한 연산이 어려운 순수 광통신망에서의 적용을 고려하여 각 검출기의 구현복잡도를 평가하고, 그 결과 Pulse-Binomial 모델과 Pulse-Poisson 모델로부터 유도된 최대공산 검출기와 AND 검출기가 검출성능과 구현용이성측면에서 최적균형점에 있음을 확인한다.

산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가 (Effect of the Number of Detectors on Performance of Industrial SPECT)

  • 박장근;김찬형;김종범;문진호;정성희
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

철도 분기기 밀착검지기 Life expectancy의 유지보수 주기 결정에 관한 연구 (Study on the Maintenance Interval Decisions for Life expectancy in Railway Turnout clearance Detector)

  • 장병목;이종우
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.491-499
    • /
    • 2017
  • 철도 분기기는 철도에 가장 중요한 시스템 중 하나이며, 분기기가 이상이 발생하였을 경우에는 사고가 발생할 수 있다. 분기기의 상태를 검지하기 위해서 밀착검지기를 사용한다. 밀착검지기의 고장은 분기기의 고장으로 간주되어 열차운행에 커다란 장애가 될 수 있다. 분기기 밀착검지기의 고장 특성분석은 분기기의 운용에서 매우 중요하다. 밀착검지기의 운용특성 및 고장특성을 분석하기 위해서, 밀착검지기를 본선(A) 및 측선(B), 분기기 동작 횟수가 10회 미만(C) 및 80회 이상(D)로 분류하였다. 선정된 밀착검지기 140대를 기준으로 밀착검지기 고장특성을 분석하였다. 분기기의 고장은 제어부, 케이블 및 검지센서에 발생하였으며, 이 데이터를 운용 환경(A, B, C, D)에 따라 분류하였으며 각각의 고장밀도함수를 선정하고 모수를 추론하여 사전분포 값을 선정하였다. Bayesian추론을 이용하여 기기의 평균수명과 한계수명(Life expectancy)을 예측하여 밀착검지기 제어부에 대한 교체시점을 제시하였다.

도막상태에 따른 열감지기의 감온특성에 관한 시험, 연구(2) (A REPORT ON THERMAL LAG OF PAINTED HEAT DETECTORS)

  • 이복영;유인호
    • 방재기술
    • /
    • 통권15호
    • /
    • pp.11-21
    • /
    • 1993
  • This report is announced about thermal lag of painted heat detectors. Thermal lag is forecast result from painting the part of heat receiving. Test is simulated that heat detector is painted by synthetic resin emulsion paint according to the cricumstance of installation, corrosion, temperature, dust.

  • PDF