• Title/Summary/Keyword: detective system

Search Result 70, Processing Time 0.026 seconds

Characteristics of research The Transmedia Storytelling in the Disney Marvel (디즈니 마블의 트랜스미디어 스토리텔링 특성 연구)

  • Kim, hui;Park, Sung-ho
    • Cartoon and Animation Studies
    • /
    • s.51
    • /
    • pp.159-179
    • /
    • 2018
  • As digital media evolves, image changes have evolved from 2D to 3D. At the end of the 1930s when the US overcame the economic crisis and met the Second World War, people needed a hero to escape reality. In DC (Detective Comics), superhero comics started to become popular by making superhero series mainly with Super Man and Bat Man. Timely Comics, founded by Martin Goodman in 1939, also published Marvel Comics, the first comic strip in epochal comics on October 1 of the same year. From this point on, Marble has developed mainly in the cartoon industry. However, in the development of the times and the change of media, Marble boldly grasps the influence of Hollywood movies from the comic centered development system, and moves from the cartoon market to the movie market. Especially, the trans-media storytelling strategy was well reflected in the movie "Avengers" series, which Marvel produced after the merger with Disney. In this paper, When Marble Comics compares with the time when the comic book industry developed before the merger and the time when the movie industry was focused after the merger with Disney What kind of change and development, and The purpose of this study is to investigate the causes of these changes.

Characteristics of a new cone beam computed tomography

  • Park, Chang-Seo;Kim, Kee-Deog;Park, Hyok;Jeong, Ho-Gul;Lee, Sang-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-209
    • /
    • 2007
  • Purpose: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). Materials and Methods: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). Results: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. Conclusion: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.

  • PDF

A Study on the Validation system of Detection for Biological Agents Using Real-Time PCR (실시간 중합효소 연쇄반응을 활용한 생물작용제 검증시스템 연구)

  • Cha, Younggil;Koo, Bonwoo;Kim, Seongjoo;Kim, Namil;Park, Hanoh
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.726-732
    • /
    • 2017
  • Bacillus anthracis, Vibrio cholerae, Variola virus and Shigella dysenteriae are classified as category A and B biological weapons. In this study suggest that 4 genes of Bacillus anthracis, 2 genes of Vibrio cholerae, 1 gene of Variola virus and 1 gene of Shigella dysenteriae were detective 50~500 fg of target DNA per reaction using real-time PCR based assay. Also analytical specificity did not show any cross-reactivity with other related bacteria. Reliable and one reaction could be effective early diagnostic and treatment for detection of unknown samples.

The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography (흉부 X선사진 농도로부터 표면선량을 산출하는 방법)

  • Kim, Jung-Min;Joon, Huo;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

A Study on the Nervous Toxic Mechanism of Cadmium (카드뮴의 신경독성 기전에 관한 연구)

  • 곽영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.45-55
    • /
    • 1995
  • This study was carried out to elucidate the toxic mechanism of cadmium in peripheral nerve. An animal model of cadmium neuropathy was induced by feeding diet containing cadmium to Sprague- Dawley rat (or two weeks. Four weeks aged Sprague- Dawley rats were divided into four groups : normal control group, 10ppm- cadmium treated group, 100ppm- cadmium treated group, 1000ppm- cadmium treated group, reference drug- treated group. All rats were sacrificed at the end of two weeks for assessing the development of cadmium neuropathy, These results obtained were summarized as follows : 1. Cadmium reduced peripheral flow of both acetylcholinesterase and cholinesterase in rat sciatic nerve. 2. The toxic mechanism of cadmium might be the result of an reduction of myo-inositol concentration in peripheral nervous system 3. Reduction in myo-inositol content of peripheral nerve resulted from the inhibition of sodium- Potassium ATPase activity, which is responsible for myo-inositol transport, by cadmium 4. Oral administration of myo-inositol improved the flow of both acetylcholinesterase and cholinesterasenerve in cadmium intoxicated rat. These results suggest that mild cadmium neuropathy might be diagnosed by checking nervous myo-inositol content and oral administraion of myo-inositol might prevent the development of severe cadmium neuropathy with special reference to detective axonal transport.

  • PDF

Effects of Pefloxacin Grinding on Pharmacokinetic Parameter in Korean Rockfish (조피볼락에서 Pefloxacin의 미분쇄가 약물동력학 Parameters에 미치는 영향)

  • 임영근;양영환;김진우;손상규;심경희;김유정;정한영;최우식;야마모토케이지
    • Journal of Life Science
    • /
    • v.9 no.3
    • /
    • pp.241-247
    • /
    • 1999
  • Antibiotics have been routinely used to control the disease of farm-raised animals in the aquaculture facilities without any criterion based on a pharmacokinetic study. This lack of information on the effective usage of antibiotics would have brought the farmers to use excessive and/or less dosages, causing the advent of drug-resistant bacteria as well as economic loss and possible contamination of the local farming area. Until recently, few studies on a detailed manual for the antibiotic usage including chemotherapy procedure, dosage, and treatment schedule of the aquatic antibiotics have been conducted throughout the world. To the worse, there is no available criterion for optimal usage of aquatic antibiotics to control diseases in aquatic farms in this country because every country has its own aquacultural system. Therefore, based on the previous studies on the usage of the various antibiotics, our studies are to focus on the development of optimal method for the detection of various antibiotics on the fate of antibiotics applied to the fish, including absorption, circulation, and secretion physiology. Pharmacokinetic study were to sep up the optimal detective condition against residual antibiotics of fish by HPLC. The grinding pefloxacin for 15 min is most effective in dissolution test and pharmacokinetic parameters. Pharmacokinetic parameters were satisfactory for 15 min-grinding products and they can be explained as one-compartment model.

  • PDF

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

DEVELOPMENT OF THE SOLAR EUV TELESCOPE ENGINEERING MODEL FOR A SATELLITE (인공위성 탑재용 극자외선 태양망원경(EUVT) EM 개발)

  • 이선민;장민환;이은석
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.327-338
    • /
    • 2003
  • The aim of this paper is to describe the results of the study on the extreme-ultra-violet (EUV) solar telescope, which is designed to. a possible satellite mission. Since the EUV band can not be observed on the ground, the observation in EUV should be performed in space using a satellite or a rocket. Design of the Extreme-Ultra-Violet solar Telescope (BUVT) in this study is based on "Designing a small-sized engineering model of solar EUV telescope for a Korean satellite" (Han et al. 2001). Our EUVT design is satisfied with the requirements for a satellite in size and input voltage. The major goal of the study is to confirm if we can detect the specific wavelength (58.4nm to 62.9nm) with the EUVT. We describe re-designing of the EUVT to decrease a shelter ratio. Also we describe the technics in the optic system and the detector, which were used to manufacture the EUVT. We explain the detective program, which is to calculate the amount of the solar radiation, and the image data processing system.ng system.

Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector (비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가)

  • Park, Ji-Koon;Kang, Sang-Sik;Cho, Sung-Ho;Shin, Jung-Wook;Kim, So-Yeong;Son, Dae-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.