• Title/Summary/Keyword: detection voltage

Search Result 918, Processing Time 0.028 seconds

A study on the Potential Detection System of Gas Insulated Switchgear (가스절연개폐장치의 전위감지 시스템에 대한 연구)

  • Choi, Seung-Kil;Baek, Seung-Kook;Kim, Kwang-Ho;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2284-2286
    • /
    • 1999
  • This paper describes the development of potential detection system in 22.9kV gas insulated switchgear. This system composed with main system and LPS can detect the source voltage by capacitive potential division which is accomplished by inserting signal electrode between main electrode and earthed metal enclosure of the switchgear. The appropriate position of signal electrode is achieved by numerical analysis using finite element method. The developed potential detection system is verified by several tests such as voltage test, swc test and others and by applicaion at site. From the results, it is concluded that potential detection system is very reliable and available to operate the switchgear safely.

  • PDF

Detection of Input Voltage Unbalance in Induction Motors Using Frequency-Domain Discrete Wavelet Transform

  • Ghods, Amirhossein;Lee, Hong-Hee;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.522-523
    • /
    • 2014
  • Analysis of faults in induction motors has become a major field of research due to importance of loss and damage reduction and maximum online performance of motors. There are several methods to analyze the faults in an induction motor from conventional Fourier transform to modern decision-making neural networks. Considering detectability of fault among all methods, a new fault detection solution has been proposed; it is called as frequency-domain Discrete Wavelet Transform (FD-DWT). In this method, the stator current is decomposed through series of low- and high-pass filters and consequently, the fault characteristics are more visible, because additional components have been reduced. The objective of this paper is early detection of input voltage unbalance in induction motor using wavelet transform in frequency domain. Experimental results show the effectiveness of the proposed method in early detection of faults.

  • PDF

Rotor Initial Polarity Detection Method of Single-Phase PMSM Considering Asymmetric Air-Gap Structure (단상 영구자석 동기 전동기의 비대칭 공극 구조를 고려한 회전자 초기 자극 검출 기법)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Park, Jong-Won;Kim, Yong-Hyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.80-83
    • /
    • 2022
  • This paper proposes an initial rotor polarity detection algorithm of a single-phase permanent magnet synchronous motor (SP-PMSM) related to stable open-loop starting for sensorless operation. Generally, the SP-PMSM needs an asymmetric air-gap structure to can avoid the initial starting failure at zero torque point. Therefore, the rotor polarity information can be obtained by using the DC offset current direction of a stator current through a high frequency voltage injection into an SP-PMSM with an asymmetric air gap. In this paper, the proposed rotor initial polarity detection algorithm is verified through several experimental results.

A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage (고장 전압의 correlation을 이용한 2차 아크 소호 판별)

  • Jang, Won-Hyeok;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

The Circuit design for Neutron Detection (중성자 검출을 위한 회로설계)

  • Kim, Sang-Jin;Seong, Nak-Jin;Kim, Ki-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.42-46
    • /
    • 2003
  • In this study, to measure the moisture of compaction, it is designed to use the 2neutron detectors. To perform the optimal design of their circuit, it is planned high voltage generator and voltage stable circuit and they are very suitable for detection demand. Also, it can be count to data calibration excluded count of ripple.

  • PDF

Development of Misfire Detection Using Spark-plug (스파크플러그를 이용한 실화감지에 관한 연구)

  • 채재우;이상만;정영식;최동천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.27-37
    • /
    • 1997
  • Internal combustion engine is the main source of environmental pollutants and therefore better technology is required to reduce harmful elements from the exhaust gases all over the world. Especially, harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. the object of this research is to detect abnormal combustion like misfire and to keep the engine performance in the optimal operating state. Development of a new system therefore could be applied to a real car. To realize this, the spark-plug in a conventional ignition system is used as a misfire detection sensor and breakdown voltage is analyzed. In this research, bias voltage(about 3kV) was applied to the electrodes of spark-plug and breakdown voltage signal is obtained. This breakdown voltage signal is analyzed and found that a combustion phenomena in engine cylinder has close relationship with harmonic coefficient K which was introduced in this research. Newly developed combustion diagnostic method( breakdown voltage signal analysis) from this research can be used for the combustion diagnostic and combustion control system in an real car.

  • PDF

Detection of Voltage Sag using An Adaptive Extended Kalman Filter Based on Maximum Likelihood

  • Xi, Yanhui;Li, Zewen;Zeng, Xiangjun;Tang, Xin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1016-1026
    • /
    • 2017
  • An adaptive extended Kalman filter based on the maximum likelihood (EKF-ML) is proposed for detecting voltage sag in this paper. Considering that the choice of the process and measurement error covariance matrices affects seriously the performance of the extended Kalman filter (EKF), the EKF-ML method uses the maximum likelihood method to adaptively optimize the error covariance matrices and the initial conditions. This can ensure that the EKF has better accuracy and faster convergence for estimating the voltage amplitude (states). Moreover, without more complexity, the EKF-ML algorithm is almost as simple as the conventional EKF, but it has better anti-disturbance performance and more accuracy in detection of the voltage sag. More importantly, the EKF-ML algorithm is capable of accurately estimating the noise parameters and is robust against various noise levels. Simulation results show that the proposed method performs with a fast dynamic and tracking response, when voltage signals contain harmonics or a pulse and are jointly embedded in an unknown measurement noise.

Design of a 6-bit 500MS/s CMOS A/D Converter with Comparator-Based Input Voltage Range Detection Circuit (비교기 기반 입력 전압범위 감지 회로를 이용한 6비트 500MS/s CMOS A/D 변환기 설계)

  • Dai, Shi;Lee, Sang Min;Yoon, Kwang Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.4
    • /
    • pp.303-309
    • /
    • 2013
  • A low power 6-bit flash ADC that uses an input voltage range detection algorithm is described. An input voltage level detector circuit has been designed to overcome the disadvantages of the flash ADC which consume most of the dynamic power dissipation due to comparators array. In this work, four digital input voltage range detectors are employed and each input voltage range detector generates the specific clock signal only if the input voltage falls between two adjacent reference voltages applied to the detector. The specific clock signal generated by the detector is applied to turn the corresponding latched comparators on and the rest of the comparators off. This ADC consumes 68.82mW with a single power supply of 1.2V and achieves 4.9 effective number of bits for input frequency up to 1MHz at 500 MS/s. Therefore it results in 4.75pJ/step of Figure of Merit (FoM). The chip is fabricated in 0.13-um CMOS process.

Effect of Surface Charging on the SIMS Depth Profile of Bismuth Titanate Thin Film (SIMS 분석조건이 Bismuth Titanate 박막의 깊이방향 조성 해석에 미치는 영향)

  • Kim, Jae Nam;Lee, Sang Up;Kwun, Hyug Dae;Shin, Kwang Soo;Chon, Uong;Park, Byung Ok;Cho, Sang Hi
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.486-493
    • /
    • 2001
  • The effect of SIMS analysis conditions such as mesh grid, offset voltage and ion species on the in-depth profile for bismuth titanate thin film was examined in terms of charging effect and detection limit. The results shows that the use of offset voltage -40 V reduces the charging effect and the detection limit. The employment of mesh grid in sample preparation leads to the reduction of the charging effect in small amount, but deteriorate the detection limit. Utilization of primary $O^-$ ion for SIMS analysis of bismuth titanate thin film showed almost the same effect as using offset voltage -40 V. However, it takes approximately triple acquisition time than using $O_2{^+}$ ion due to the poor beam current of the source in the experiment.

  • PDF

The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System (단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.