• Title/Summary/Keyword: detection technique

Search Result 4,102, Processing Time 0.035 seconds

Comparative Assessment of a Self-sampling Device and Gynecologist Sampling for Cytology and HPV DNA Detection in a Rural and Low Resource Setting: Malaysian Experience

  • Latiff, Latiffah A;Ibrahim, Zaidah;Pei, Chong Pei;Rahman, Sabariah Abdul;Akhtari-Zavare, Mehrnoosh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8495-8501
    • /
    • 2016
  • Purpose: This study was conducted to assess the agreement and differences between cervical self-sampling with a Kato device (KSSD) and gynecologist sampling for Pap cytology and human papillomavirus DNA (HPV DNA) detection. Materials and Methods: Women underwent self-sampling followed by gynecologist sampling during screening at two primary health clinics. Pap cytology of cervical specimens was evaluated for specimen adequacy, presence of endocervical cells or transformation zone cells and cytological interpretation for cells abnormalities. Cervical specimens were also extracted and tested for HPV DNA detection. Positive HPV smears underwent gene sequencing and HPV genotyping by referring to the online NCBI gene bank. Results were compared between samplings by Kappa agreement and McNemar test. Results: For Pap specimen adequacy, KSSD showed 100% agreement with gynecologist sampling but had only 32.3% agreement for presence of endocervical cells. Both sampling showed 100% agreement with only 1 case detected HSIL favouring CIN2 for cytology result. HPV DNA detection showed 86.2%agreement (K=0.64, 95% CI 0.524-0.756, p=0.001) between samplings. KSSD and gynaecologist sampling identified high risk HPV in 17.3% and 23.9% respectively (p=0.014). Conclusion: The self-sampling using Kato device can serve as a tool in Pap cytology and HPV DNA detection in low resource settings in Malaysia. Self-sampling devices such as KSSD can be used as an alternative technique to gynaecologist sampling for cervical cancer screening among rural populations in Malaysia.

Linear Scratch Detection and Removal Technique for Old Film Sequences Using Wavelet Shrinkage and Interpolation (고전 영화 복원을 위한 웨이블릿 계수축소와 보간법을 이용한 선형 스크래치 검출 및 제거 기술)

  • Kang, Won-Seok;Lee, Eun-Sung;Kim, Sang-Jin;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.5
    • /
    • pp.1-9
    • /
    • 2011
  • This paper presents a novel scratch detection and removal approach for old film images in wavelet-domain. Various scratch detection and removal algorithms have been proposed for past decades. However, accurate scratch detection and removal with a moderate amount of computing effort is still a problem because of trade off between the quality of the film and computational load. For overcoming this problem, we first decompose an input image using a 3-level wavelet transform, and then remove the scratch by shrinking wavelet coefficients using linear interpolation. Experimental results show that the proposed algorithm can efficiently detect and remove the scratch in damaged films, and also be incorporated into old film restoration systems.

Fabrication of PDMS microlens for optical detection (광학적 검출을 위한 PDMS 마이크로렌즈의 제작)

  • Park, Se-Wan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.15-20
    • /
    • 2009
  • In a detection system based on laser light scattering, focusing an excitation laser beam into a focal point of a channel in a microfluidic chip is important for obtaining the highest excitation intensity, and consequently for obtaining a laser light scattering signal using a photodetector with a high efficiency. In this paper, we present a polydimethylsiloxane (PDMS) microfluidic chip consisting of an integrated PDMS microlens for cell detection based on laser light scattering. We fabricated PDMS microlens for optical detection system by simply putting down on PDMS chips. The PDMS microlens was fabricated by photoresist reflow and replica molding. This fabrication technique is simple and has an excellent property in terms of the microlens and a high-dimensional accuracy. The PDMS microlens integrated on the PDMS microfluidic chip has been verified to improve the laser intensity, and accordingly, the signal-to-noise ratio and sensitivity of laser light scattering detection for red blood cells(RBCs)

A preliminary study on the development of detection techniques for CO2 gas bubble plumes (CO2 가스 기포 누출 탐지 기술 개발을 위한 예비 연구)

  • Kum, Byung-Cheol;Cho, Jin Hyung;Shin, Dong-Hyeok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1163-1169
    • /
    • 2014
  • As a preliminary study for detection techniques of $CO_2$ gas bubble plumes, we have conducted a comparative experiment on artificially generated $CO_2$ gas bubbles plume by using multibeam echosounder (MBES), single beam echosounder (SBES), and sub-bottom profiler (SBP). The rising speed of artificial gas bubbles is higher than references because of compulsory release of compressed gas in the tank. Compared to single beam acoustic equipments, the MBES detects wide swath coverage. It provides exact determination of the source position and 3D information on the gas bubble plumes in the water column. Therefore, it is shown that MBES can distinctly detect gas bubble plumes compared to single beam acoustic equipments. We can establish more effective complementary detection technique by simultaneous operation of MBES and SBES. Consequently, it contributes to improve qualitative and quantitative detection techniques by understanding the acoustic characteristics of the specific gas bubbles.

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

A Disposable Grating-Integrated Multi-channel SPR Sensor Chip for Detection of Biomolecule (회절격자가 집적된 일회용 다중채널 SPR 생체분자 검출 칩)

  • Jin, Young-Hyun;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.147-154
    • /
    • 2009
  • This paper presents a grating~integrated SPR (Surface Plasmon Resonance) sensor chip for simple and inexpensive biomolecule detection. The grating-integrated SPR sensor chip has two sensing channels having a nano grating for SPR coupling. An external mirror is used for multi channel SPR sensing. The present sensor chip replaces bulky and expensive optical components, such as fiber-optic switches or special shaped prisms, resulting in a simple and inexpensive wavelength modulated multi-channel SPR sensing system. We fabricate a SPR sensor chip integrated with 835 nm-pitch gratings by a micromolding technique to reduce the fabrication cost. In the experimental characterization, the refractive index sensitivity of each sensing channel is measured as $321.8{\pm}8.1nm$/RI and $514.3{\pm}8.lnm$/RI, respectively. 0.5uM of the target biomolecule (streptavidin) was detected by a $1.13{\pm}0.16nm$ shift of the SPR dip in the 10%-biotinylated sample channel, while the SPR dip in the reference channel for environmental perturbation monitoring remained at the same position. From the experimental results, multi-channel biomolecule detection capability of the present grating-integrated SPR sensor chip has been verified. On the basis of the preliminary experiments, we successfully measured the binding reaction rate for the $2\;nM{\sim}200\;nM$ monoclonal-antibiotin, thus verifying biomolecule concentration detectability of the present SPR sensor chip. The binding reaction rates measured from the present SPR sensor chip agredd well with those from a commercialized SPR sensor.

A systematic method from influence line identification to damage detection: Application to RC bridges

  • Chen, Zhiwei;Yang, Weibiao;Li, Jun;Cheng, Qifeng;Cai, Qinlin
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.563-572
    • /
    • 2017
  • Ordinary reinforced concrete (RC) and prestressed concrete bridges are two popular and typical types of short- and medium-span bridges that accounts for the vast majority of all existing bridges. The cost of maintaining, repairing or replacing degraded existing RC bridges is immense. Detecting the abnormality of RC bridges at an early stage and taking the protective measures in advance are effective ways to improve maintenance practices and reduce the maintenance cost. This study proposes a systematic method from influence line (IL) identification to damage detection with applications to RC bridges. An IL identification method which integrates the cubic B-spline function with Tikhonov regularization is first proposed based on the vehicle information and the corresponding moving vehicle induced bridge response time history. Subsequently, IL change is defined as a damage index for bridge damage detection, and information fusion technique that synthesizes ILs of multiple locations/sensors is used to improve the efficiency and accuracy of damage localization. Finally, the feasibility of the proposed systematic method is verified through experimental tests on a three-span continuous RC beam. The comparison suggests that the identified ILs can well match with the baseline ILs, and it demonstrates that the proposed IL identification method has a high accuracy and a great potential in engineering applications. Results in this case indicate that deflection ILs are superior than strain ILs for damage detection of RC beams, and the performance of damage localization can be significantly improved with the information fusion of multiple ILs.

A Hybrid Multiuser Detection Algorithm for Outer Space DS-UWB Ad-hoc Network with Strong Narrowband Interference

  • Yin, Zhendong;Kuang, Yunsheng;Sun, Hongjian;Wu, Zhilu;Tang, Wenyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.5
    • /
    • pp.1316-1332
    • /
    • 2012
  • Formation flying is an important technology that enables high cost-effective organization of outer space aircrafts. The ad-hoc wireless network based on direct-sequence ultra-wideband (DS-UWB) techniques is seen as an effective means of establishing wireless communication links between aircrafts. In this paper, based on the theory of matched filter and error bits correction, a hybrid detection algorithm is proposed for realizing multiuser detection (MUD) when the DS-UWB technique is used in the ad-hoc wireless network. The matched filter is used to generate a candidate code set which may contain several error bits. The error bits are then recognized and corrected by an novel error-bit corrector, which consists of two steps: code mapping and clustering. In the former step, based on the modified optimum MUD decision function, a novel mapping function is presented that maps the output candidate codes into a feature space for differentiating the right and wrong codes. In the latter step, the codes are clustered into the right and wrong sets by using the K-means clustering approach. Additionally, in order to prevent some right codes being wrongly classified, a sign judgment method is proposed that reduces the bit error rate (BER) of the system. Compared with the traditional detection approaches, e.g., matched filter, minimum mean square error (MMSE) and decorrelation receiver (DEC), the proposed algorithm can considerably improve the BER performance of the system because of its high probability of recognizing wrong codes. Simulation results show that the proposed algorithm can almost achieve the BER performance of the optimum MUD (OMD). Furthermore, compared with OMD, the proposed algorithm has lower computational complexity, and its BER performance is less sensitive to the number of users.

A Study on Automatic Coregistration and Band Selection of Hyperion Hyperspectral Images for Change Detection (변화탐지를 위한 Hyperion 초분광 영상의 자동 기하보정과 밴드선택에 관한 연구)

  • Kim, Dae-Sung;Kim, Yong-Il;Eo, Yang-Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.5
    • /
    • pp.383-392
    • /
    • 2007
  • This study focuses on co-registration and band selection, which are one of the pre-processing steps to apply the change detection technique using hyperspectral images. We carried out automatic co-registration by using the SIFT algorithm which performance was already established in the computer vision fields, and selected the bands fur change detection by estimating the noise of image through the PIFs reflecting the radiometric consistency. The EM algorithm was also applied to select the band objectively. Hyperion images were used for the proposed techniques, and non-calibrated bands and striping noises contained in Hyperion image were removed. Throughout the results, we could develop the reliable co-registration procedure which coincided with accuracy within 0.2 pixels (RMSE) for change detection, and verified that band selection depending on the visual inspection could be objective by extracting the PIFs.

Study on the Ship Detection Method Using SAR Imagery (SAR 영상을 이용한 선박탐지에 관한 연구)

  • Kwon, Seung-Joon;Shin, Sung-Woong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 2009
  • The existing vessel monitoring system using the ground surveillance radar has a difficulty in monitoring ships continuously due to the limited range of detecting ships. For resolving this problem, we carry out a research on ship detection which is to be the core technology of vessel monitoring system for ocean monitoring using SAR imagery. There are two different methods of detecting ships in SAR imagery: detection of the ship target itself and detection of the ship wake. In this paper, we mainly focus on algorithms which detect the ship itself, and also present the accuracy test after extracting positional and directional figures of the ships. After rectifying input SAR imagery using polynomial transformation, we use Wiener filter to remove speckle noises. A labeling technique and morphological filtering in conjunction with Otsu's method are used to automatically detect the ships based on the image processing domain. For ground truth data, information from a radar system is used, which allows assessing the accuracy of the proposed method. The results show that the proposed method has the high potential in automatically detecting the ships and its positional/directional figures in a fast way.

  • PDF