• Title/Summary/Keyword: design (buildings)

Search Result 3,493, Processing Time 0.03 seconds

A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea (건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향)

  • Lee, Ah-Young
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

Earthquake performance investigation of R/C residential buildings in Turkey

  • Korkmaz, Kasim Armagan;Demir, Fuat;Yenice, Tugce
    • Computers and Concrete
    • /
    • v.15 no.6
    • /
    • pp.921-933
    • /
    • 2015
  • The aim of this study is to determine the earthquake performances of reinforced concrete (R/C) residential buildings in Turkey and to analyze the parameters that affect the performance. The performance of Turkish residential buildings, determined by their levels of damage, directly relates to their structural systems. Damage parameters observed from previous earthquakes define structural parameters selected to be used in the present study. Five different types of frame R/C buildings were modeled. For the analysis, the model buildings vary according to the number of stories, column sizes, and reinforcement and concrete strength parameters. The analyses consider gravity forces and earthquake loads through 1975 and 2007 Turkish design codes. In a total of 720 different R/C buildings were investigated for the analysis to obtain capacity curves. A performance evaluation was employed by considering the Turkish design code (TDC-2007). The current study ignores irregularities such as soft stories or short columns. The study's analysis considers a comparison of the parameters' influence on the structural performance of the model buildings.

Knowledge Support and Automation of Paneled Building Envelopes for Complex Buildings using Script Programming

  • Park, Jungdae;Im, Jinkyu
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.85-90
    • /
    • 2015
  • Advances in the technology of computational design are giving architects and engineers the opportunity to analyze buildings with complex geometries. This study explores the optimization and automation process using the parametric design method, and uses digital tools to achieve surface representation and panelization for curved shaped office buildings. In this paper, we propose parametric algorithms of dimensional and geometric constraints using the Knowledge-ware scripts embedded in Gehry Technologies' Digital Project. The knowledge-based design methods proposed in this study can be used to systemize the knowledge possessed by experts in the form of data. Such knowledge is required to promote collaboration between designers and engineers in the process of CAD/CAE/CAM. The aim of this study is to integrate the process into design, which establishes an integrated process. This integration enables two-way feedback between design and construction data by combining the methods used in designing, engineering, and construction.

Integrated Structural Design of Oceanic Buildings using STEP (STEP을 이용한 해양건축물의 통합구조설계 기법)

  • 송화철
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.77-86
    • /
    • 2000
  • The planning process of complex projects in oceanic architectural engineering is characterized by the cooperation of many involved specialists and by a high degree of information exchange. In order to improve the quality of the structural design of oceanic buildings, information of different involved partners in the planning process has to be integrated. This paper aims to introduce a concept of the integrated structural design for the floating-type oceanic building using STEP(Standard for the Exchange of Product Model Data). STEP(ISO 10303) is an international standard for the computer-interpretable representation and exchange of product data and it provides a consistent data exchange format and application interfaces between different application systems. In this paper, the structural design process and information of oceanic buildings is analyzed and product models are preposed fir the exchange of the structural design information between superstructure and floating structure. The entities for calculating wind loads, metacenter and restoring forces are represented by Express. As a case study a floating hotel is applicated to describe the STEP physical file.

  • PDF

Examination of the effects on earthquake behavior and rough construction costs of short column situation occurring in reinforced concrete buildings

  • Gursoy, Senol;Cavusoglu, Aykut
    • Earthquakes and Structures
    • /
    • v.20 no.3
    • /
    • pp.309-323
    • /
    • 2021
  • Architectural design decisions and structural systems arrangements affect their earthquake behaviors significantly of reinforced concrete building in Turkey. Because the performances as safe and economical against earthquake loads of reinforced concrete buildings can be provided with especially design decisions in the architectural design stage. This matter reveals the importance of design decisions in the architectural design phase and the right structural system arrangement. The purpose of this study, the short-column situation frequently observed in reinforced concrete buildings after the earthquakes occurred in Turkey are to examine comparatively the effects on behavior and the rough construction cost of the building. The obtained results show that the short column circumstance composed due to different reasons negatively affects the earthquake performance of the reinforced concrete buildings and increases the rough construction cost. This matter shows that the measures to be taken against short column formation should be foreseen especially at the architectural design stage.

Performance of reinforced concrete moment resisting frames in Sarpol-e Zahab earthquake (November 12, 2017, Mw=7.3), Iran

  • Mohammad Amir Najafgholipour;Mehrdad Khajepour
    • Earthquakes and Structures
    • /
    • v.25 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Reinforced concrete (RC) moment frames are used as lateral seismic load resisting systems in mid- and high-rise buildings in different regions of the world. Based on the seismic design provisions and construction details presented in design codes, RC frames with different levels of ductility (ordinary, intermediate, and special) can be designed and constructed. In Iran, there are RC buildings with various uses which have been constructed based on different editions of design codes. The seismic performance of RC structures (particularly moment frames) in real seismic events is of great importance. In this paper, the observations made on damaged RC moment frames after the destructive Sarpol-e Zahab earthquake with a moment magnitude of 7.3 are reported. Different levels of damage from the development of cracks in the structural and non-structural elements to the total collapse of buildings were observed. Furthermore, undesirable failure modes which are not expected in ductile seismic-resistant buildings were frequently observed in the damaged buildings. The RC moment frames built based on the previous editions of the design codes showed partial or total collapse in this seismic event. The extensive destruction of RC moment frames compared with the other structural systems (such as braced steel frames and confined masonry buildings) was attributed not only to the deficiencies in the construction practice of these buildings but also to the design procedure. In addition, the failure and collapse of masonry infills in RC moment frames were frequent modes of failure in this seismic event. In this paper, the main reasons related to design practice which led to extensive damage in the RC moment frames and their collapse are addressed.

New Approach to Integrated Structural Analysis and Design for Multistory RC/Post-Tensioned Buildings (ADAPT Edge 2012-RC/PT 다층 구조물 해석 및 설계 프로그램)

  • Aalami, Florian;Lee, Soo Heon
    • Computational Structural Engineering
    • /
    • v.25 no.4
    • /
    • pp.63-70
    • /
    • 2012
  • This article introduces ADAPT Corporation's latest software product for the integrated multistory analysis and design of concrete buildings, ADAPT Edge. Edge uniquely packages user-friendly modeling of multistory buildings, accurate gravity and lateral analysis, post-tensioning, and detailed slab and beam design, all in one software package. The benefits of Edge over traditional concrete design software are explained.

Performance-based design of seismic isolated buildings considering multiple performance objectives

  • Morgan, Troy A.;Mahin, Stephen A.
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.655-666
    • /
    • 2008
  • In the past 20 years, seismic isolation has see a variety of applications in design of structures to mitigate seismic hazard. In particular, isolation has been seen as a means of achieving enhanced seismic performance objectives, such as those for hospitals, critical emergency response facilities, mass electronic data storage centers, and similar buildings whose functionality following a major seismic event is either critical to the public welfare or the financial solvency of an organization. While achieving these enhanced performance objectives is a natural (and oftentimes requisite) application of seismic isolation, little attention has been given to the extension of current design practice to isolated buildings which may have more conventional performance objectives. The development of a rational design methodology for isolated buildings requires thorough investigation of the behavior of isolated structures subjected to seismic input of various recurrence intervals, and which are designed to remain elastic only under frequent events. This paper summarizes these investigations, and proposed a consistent probabilistic framework within which any combination of performance objectives may be met. Analytical simulations are presented, the results are summarized. The intent of this work is to allow a building owner to make informed decisions regarding tradeoffs between superstructure performance (drifts, accelerations) and isolation system performance. Within this framework, it is possible to realize the benefits of designing isolated buildings for which the design criteria allows consideration of multiple performance goals.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.