• 제목/요약/키워드: desalination plant

검색결과 112건 처리시간 0.026초

일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구 (Experimental Study on Design Verification of New Concept for Integral Reactor Safety System)

  • 정문기;최기용;박현식;조석;박춘경;이성재;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF

해수담수화 시설의 에너지 효율 향상을 위한 최적위치 검토 (The review of optimal location for enhanced energy efficiency in seawater desalination plant)

  • 심규대;장부건;박용균;정준연;김동균
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.201-201
    • /
    • 2019
  • 세계적인 기상이변으로 가뭄발생 빈도 및 영향이 증가하고 있으며, 급속한 산업화로 사용 가능한 수자원이 점차 고갈되어 있어, 국내에서도 해수담수화(Seawater Desalination)는 새로운 대체수자원으로 많은 관심을 받고 있다. 해수담수에 필요한 에너지 약 50~70%는 역삼투(Reverse Osmosis) 공정에서 발생되며, 해수온도 및 염분도에 따라 많이 변동될 수 있으므로 국립해양조사원(KHOA)의 과거 20년 자료를 이용하여 해수담수화 시설물 위치에 따른 영향을 분석하였다. 해수담수화에 필요한 에너지는 막 제조사에서 제공하는 RO Projection Software를 적용하여 에너지 소모량을 평가하고, 이를 고려한 시설물 위치에 대한 평가 모델을 구축하였다. 기존 해수담수화 시설은 대규모 물 공급이 필요한 지역을 우선적으로 고려했기 때문에 시설물 위치에 대한 객관적인 평가기준 마련이 어려웠다. 그러나 해수담수화 플랜트는 한번 설치되면 장기적인 시설물 유지 및 관리가 필요함으로 경제성을 고려한 최적 입지의 선정은 매우 중요하다. 본 연구는 국립해양조사원의 수집된 자료를 바탕으로 해수담수화 시설물 입지선정을 정량적으로 평가함으로서, 시설물 위치에 대한 의사결정시 참고할 수 있는 기초자료로 활용될 것으로 기대한다.

  • PDF

Membrane Biofouling of Seawater Reverse Osmosis Initiated by Sporogenic Bacillus Strain

  • Lee, Jin-Wook;Ren, Xianghao;Yu, Hye-Weon;Kim, Sung-Jo;Kim, In-S.
    • Environmental Engineering Research
    • /
    • 제15권3호
    • /
    • pp.141-147
    • /
    • 2010
  • The objective of this study was to assess the biofouling characteristics of the Bacillus biofilm formed on reverse osmosis (RO) membranes. For the study, a sporogenic Bacillus sp. was isolated from the seawater intake to a RO process, with two distinct sets of experiments performed to grow the Bacillus biofilm on the RO membrane using a lab-scale crossflow membrane test unit. Two operational feds were used, 9 L sterile-filtered seawater and 109 Bacillus cells, with flow rates of 1 L/min, and a constant 800 psi-pressure and pH 7.6. From the results, the membrane with more fouling, in which the observed permeate flux decreased to 33% of its initial value, showed about 10 and 100 times greater extracellular polymeric substances and spoOA genes expressions, respectively, than the those of the less fouled membrane (flux declined to 20% of its initial value). Interestingly; however, the number of culturable Bacillus sp. in the more fouled membrane was about 10 times less than that of the less fouled membrane. This indicated that while the number of Bacillus had less relevance with respect to the extent of biofouling, the activation of the genes of interest, which is initiative of biofilm development, had a more positive effect on biofouling than the mass of an individual Bacillus bacterium.

다중효용 담수설비용 열압축기의 디퓨져 입구부 형상에 관한 연구 (A Study on the Diffuser Inlet Shape of Thermocompressor for MED Desalination Plant)

  • 김창복;송영호;김경근;박기태;정한식;최두열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.869-876
    • /
    • 2008
  • A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.

MD/RO 담수화 플랜트에서 발생한 농축수의 Ca 및 Mg 전처리를 위한 침전 처리 특성 (Characteristics of precipitation treatment for Ca and Mg pretreatment of brine generated from MD/RO desalination plant)

  • 심재호;박재철;임대환;박주양
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.329-338
    • /
    • 2017
  • The problem of disposal of brine due to increased MD/RO desalination plant has recently become a big social issue. The chlor-alkali process through electrolysis of brine has been studied as a method to overcome this problem. In order to increase the electrolysis efficiency, a pretreatment process for removal of hard substances must be preceded. In this study, we investigated the mechanism of removal of hardness through chemical precipitation. As a result, Ca was greatly influenced by addition of $Na_2CO_3$, and Mg was strongly influenced by pH. Also, the addition of NaOH and $Na_2CO_3$ enabled simultaneous removal of Ca and Mg, and showed a removal efficiency of 99.9% or more. Finally, the residual concentrations of Ca and Mg in the brine after the reaction were 0.14 and 0.13 mg/L, respectively. Saturation index was calculated using Visual MINTEQ 3.1, and solid phase analysis of the precipitate was performed by FE-SEM and PXRD analysis. It was confirmed that precipitate formed by the formation of calcite and brucite.

원수 블렌딩이 해수담수화 역삼투 공정 성능에 미치는 영향 (Impact Analysis of Water Blending to Reverse Osmosis Desalination Process)

  • 김지혜;박형진;이경혁;권병수;권순범;임재림
    • 멤브레인
    • /
    • 제30권3호
    • /
    • pp.190-199
    • /
    • 2020
  • 2018년 환경부에서 발표된 수도정비기본계획에 따라 다양한 수자원 활용의 중요성이 증가하고 있으며, 여러 수원을 혼합하여 원수 또는 생산수로 활용하는 워터 블렌딩 방식은 미국, 호주를 비롯한 여러 나라에서 시도되고 있다. 본 연구에서는 공업용수 공급 목적으로 100,000 ㎥/일 규모 해수담수화 사업이 추진되고 있는 충남 대산 지역을 대상으로, 해수와 호소수, 침전수, 폐수 방류수 등 타 수원을 블렌딩할 때 수종 및 혼합비율에 따른 영향을 분석하였다. 타 수원 혼합비율 10~50% 조건에서 혼합수 염분농도는 약 50%까지 감소하였지만, 탁질 및 유기물 농도는 1.6~2.0배 수준으로 증가하는 것을 확인하였다. 실험실 규모 역삼투 공정 성능평가 결과, 해수의 단독활용 대비 원수 혼합 시 막오염 경향이 증가하였으며 혼합비율 10~50%에서 평균 4.1배의 플럭스 저감률을 나타내었다. 성능모사를 통한 역삼투 공정 성능분석에 따르면 혼합비율 50% 조건에서 역삼투 공정 에너지 사용량이 평균 39% 절감될 수 있을 것으로 기대되나, 운영비용 등 혼합수 활용에 대한 전반적인 영향분석을 위해서는 모형플랜트 규모에서 장기간 성능평가가 필요하다.

면역 알고리즘을 이용한 RO 공정 PID 제어기의 자동 튜닝 (Auto Tuning of PID for RO System Using Immune Algorithm)

  • 김고은;박지모;김진성;권오신;허훈
    • 한국소음진동공학회논문집
    • /
    • 제19권11호
    • /
    • pp.1103-1109
    • /
    • 2009
  • In this paper, the control of a membrane used in reverse osmosis desalination plant by using immune algorithm(IA) is addressed. The proposed algorithm IA of auto tuning method can find optimal gains and compared with conventional Ziegler-Nichols tuning method. The results of computer simulation represent that the proposed IA shows a good control performances better than Ziegler-Nichols tuning method.

키리바시 타라와의 지속가능발전목표 달성 지원을 위한 해수플랜트 기술 활용 (Application of Seawater Plant Technology for supporting the Achievement of SDGs in Tarawa, Kiribati)

  • 최미연;지호;이호생;문덕수;김현주
    • 적정기술학회지
    • /
    • 제7권2호
    • /
    • pp.136-143
    • /
    • 2021
  • 키리바시를 포함한 태평양 도서국가들은 기후 변화, 지하수 오염 및 식생 변화로 인한 해수면 상승 및 해안 침식으로 인해 생활 공간의 감소 뿐만 아니라 필수 자원 부족으로 고통받고 있다. 이러한 문제를 해결하기 위한 글로벌 활동은 SDGs 이행을 위한 UN의 노력으로 진행되고 있다. 태평양 도서 국가들이 풍부한 해양 자원을 이용하여 기후 변화에 대응하고 적응할 수 있도록 모색해 왔다. 즉, 해수 플랜트는 이러한 태평양 도서 국가에서 SDG # 14를 기반으로 SDG #2, #6 및 #7을 달성하는 데 도움을 줄 수 있다. 선박해양플랜트연구소(KRISO)는 2016년에 설립한 지속가능 해수이용 아카데미(SSUA)를 통해 키리바시 SSUA협회를 결성하고, 해양수산부(MOF)의 해양수산 ODA사업으로 키리바시에 해수플랜트를 지원하였다. 키리바시 SSUA협회는 해수 및 태양에너지를 이용하는 해수플랜트를 이용하여, 2018년부터 2020년까지 지역 사회에 식수와 채소를 공급하는 공익사업을 하고 있다. 역량강화 과정을 통해 키리바시 SSUA협회는 기술 이전을 받았고, 지역사회에 수경재배 시스템의 설치, 모종과 비료 보급, 재배관리 기술지도 및 모니터링을 실시하였다. 협회는 3년 동안 140여 가구에 수경재배 시스템(일부는 태양광발전 패널 제공)을 보급하고, 다양한 채소를 재배하여 자가 소비 또는 판매하게 하였다. 또한, 태양광발전 연계 해수담수화 시스템을 설치하여 식수를 공급하도록 하고 있다. 만족도 조사를 통해 대부분의 수혜 가구가 만족하였고, 주변 지역 및 도서로 보급확산을 희망하고 있음을 알 수 있었다. 따라서, 키리바시 SSUA협회는 공동체 이용 및 관리 체계화를 지원하는 자활사업을 추진할 계획이며, 이러한 활동은 태평양 도서국가들의 SDGs 달성을 지원하기 위한 ODA 프로그램으로 확산될 수 있을 것이다.

간척지 사료작물 재배에 있어서 모래를 이용한 토양 mulching의 효과 I. 제염효과와 작물생육 (Effects of Sand Mulching on Forage Production in Newly Reclaimed Tidal Lands I. Desalination of the soils and crop perfomanc)

  • 김정갑;한민수;이상범;한흥전
    • 한국초지조사료학회지
    • /
    • 제8권1호
    • /
    • pp.55-60
    • /
    • 1988
  • A two year's field experiment was conducted on newly reclaimed saline tidal lands to measure the effects of sand mulching on salinity of the soils and their relationship to crop performance. Hybrid sorghum cv. Pioneer 931 was grown under different mulching treatments using of medium sand and red earth (Fine loamy, Typic Hapludults). Salinity in the root zone was decreased markedly under soil mulching using of medium sand, especially during the dry season, and it caused a great increase in the root growth and R/T ratio. Seasonal values of electrical conductivity at sand mulching were 6.6 in April and 1.6 mmhos in August, but it was still high with a concentration of 12.7 (April) and 3.8 mmhos (August) in untreated check plot. Sand mulching increased plant growth and the rate of dry matter accumulation. However, treatment of red earth additionally over sand mulching produced lower dry matter yield than those of soil mulching using of medium sand only. Under salt stress sorghum plant showed a decrease in the leaf weight ratio (LWR) and it resulted in a low concentration of crude protein of the plant. Sand mulching enhanced leaf weight ratio and rate of protein synthesis.

  • PDF

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.