• Title/Summary/Keyword: derivatization method

검색결과 192건 처리시간 0.026초

Amphetamine-type Stimulants in Drug Testing

  • Chung, Heesun;Choe, Sanggil
    • Mass Spectrometry Letters
    • /
    • 제10권1호
    • /
    • pp.1-10
    • /
    • 2019
  • Amphetamine-type stimulants (ATS) are a group of ${\beta}$-phenethylamine derivatives that produce central nervous system stimulants effects. The representative ATS are methamphetamine and 3, 4-methylenedioxymethamphetamine (MDMA), and abuse of ATS has become a global problem. Methamphetamine is abused in North America and Asia, while amphetamine and 3, 4-methyle nedioxym ethamphetamine (Ecstasy) are abused in Europe and Australia. Methamphetamine is also the most abused drug in Korea. In addition to the conventional ATS, new psychoactive substances (NPS) including phenethylamines and synthetic cathinones, which have similar effects and chemical structure to ATS, continue to spread to the global market since 2009, and more than 739 NPS have been identified. For the analysis of ATS, two tests that have different theoretical principles have to be conducted, and screening tests by immunoassay and confirmatory tests using GC/MS or LC/MS are the global standard methods. As most ATS have a chiral center, enantiomer separation is an important point in forensic analysis, and it can be conducted using chiral derivatization reagents or chiral columns. In order to respond to the growing drug crime, it is necessary to develop a fast and efficient analytical method.

Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector

  • Kwon, Oh-Seung;Kim, Hye-Jung;Pyo, Hee-Soo;Kim, Dae-Duk;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권5호
    • /
    • pp.383-388
    • /
    • 2005
  • A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT $(Testo^{TM}\;tablets,\;25\;mg)$ for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r>0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01 %, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of $AUC_{0\;to\;last}$ to last was $264.5{\pm}123.9\;ng{\cdot}hr/ml$ and that of $AUC_{0\;to\;inf}$ was determined to be $275.2{\pm}126.5\;ng{\cdot}hr/ml$. The values of $C_{max}$ and $T_{max}$ were $95.9{\pm}67.1\;ng/ml$ and $1.13{\pm}0.9\;hr$, respectively. The mean elimination half-life $(t_{1/2})$ was $4.4{\pm}0.9\;hr$. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT.

혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단 (A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia)

  • 윤혜란;마헤샬타파
    • 대한유전성대사질환학회지
    • /
    • 제15권3호
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Determination of Ceftiofur Residues by Simple Solid Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry in Eel, Flatfish, and Shrimp

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Lee, Eunhye;Choi, Soo Yeon;Lee, Hee-Seok;Cho, Byung-Hoon;Lee, Kang-Bong;Jeong, Jiyoon
    • Mass Spectrometry Letters
    • /
    • 제10권2호
    • /
    • pp.43-49
    • /
    • 2019
  • The aim of this study was conducted to develop an analytical method to determine the concentration of ceftiofur residue in eel, flatfish, and shrimp. For derivatization and extraction, the sample was hydrolyzed with dithioerythritol to produce desfuroylceftiofur, which was then derivatized by iodoacetamide to obtain desfuroylceftiofur acetamide. For purification, the process of solid phase extraction (Oasis HLB) was used. The target analytes were confirmed and quantified in $C_{18}$ column using liquid chromatography-tandem mass spectrometry with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as the mobile phase. The linearity of the standard calibration curve was confirmed by a correlation coefficient, $r^2>0.99$. The limit of quantification for ceftiofur was 0.002 mg/kg; the accuracy (expressed as the average recoveries) was 80.6-105%; the precision (expressed as the coefficient of variation) was below 6.3% at 0.015, 0.03, and 0.06 mg/kg. The validated method demonstrated high accuracy and acceptable sensitivity to meet the Codex guideline requirements. The developed method was tested using market samples. As a results, ceftiofur was detected in one sample. Therefore, it can be applied to the analysis of ceftiofur residues in fishery products.

타액 중 페닐알킬아민유도체류의 일제분석법 확립 (Development of Simultaneous Quantification Method of Phenylalkylamines in Oral Fluid)

  • 최혜영;백승경;장문희;최화경;정희선
    • 약학회지
    • /
    • 제55권2호
    • /
    • pp.145-153
    • /
    • 2011
  • A simultaneous detection and quantification method for determining the Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), ketamine (KT), norketamine (NKT), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), in oral fluid was developed and validated according to international guidelines. The validated method was applied to actual oral fluid samples collected from drug abuse suspects. The recovery of phenylalkylamines from oral fluid collection devices was also assessed. Oral fluid specimens from 20 drug abuse suspects submitted by the police were collected using Salivette$^{TM}$, Quantisal$^{TM}$ or direct expectoration. The samples were screened using a biochip array analyzer. For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE with a mixed-mode cation exchange cartridge and derivatization with trifluoroacetic anhydride (TFAA). The results from the immunoassay were consistent with those from GC-MS. All the oral fluid samples gave positive results for MA, AM, PT and/or PM. The detection of phenylalkylamines in oral fluid can provide a better indication of recent use than urine or hair. Therefore, the oral fluid specimen was useful for demonstrating phenylalkylamines abuse in the driving under the influence of drug (DUID) as an alternative specimen for urine.

GC-MS를 이용한 사람 뇨시료 중 비만치료제 분석 및 비만치료제 남용 현황의 법과학적 고찰 (Development of a Simultaneous Detection and Quantification Method of Anorectics in Human Urine Using GC-MS and its Application to Legal Cases)

  • 최혜영;이재신;장문희;양원경;김은미;최화경
    • 약학회지
    • /
    • 제57권6호
    • /
    • pp.420-425
    • /
    • 2013
  • Phentermine (PT) and phenmetrazine (PM) have been widely used as anti-obesity drugs. These drugs should be used with caution due to its close relation to amphetamine in its structure and toxicity. PT and PM, amphetamine-type anorectics, have recently been considered as alternatives for methamphetamine abuse in Korea. In addition, the misuse and abuse of PT and PM obtained by illegal sources such as the internet become a serious social problem. In the present study, a simultaneous detection and quantification method for determining PT and PM in human urine was developed and validated according to the international guidelines. The urine samples were screened using a fluorescence polarization immunooassay and analyzed by gas chromatography mass spectrometry (GC-MS) after extraction using automatic solid phase extraction (SPE) with a mixed-mode cation exchange cartridge and derivatization with pentafluoropropionic anhydride (PFPA). The validation results for selectivity, linearity, limits of detection (LOD) and quantification (LOQ), intra- and inter-assay precision and accuracy and recovery were satisfactory. The validated method was successfully applied to authentic urine samples collected from 38 drug abuse suspects. PT and/or PM were identified with or without methamphetamine in urine samples. Abuse of PT and PM have increased continuously in Korea, therefore, closer supervision of the inappropriate use of anoretics is necessary.

LC-MS를 이용한 수용액중의 3-MCPD 정량 (Quantitative analysis of 3-MCPD in water using LC-MS)

  • 박교범;김용화;김진성;정자영;김충용;이석근
    • 분석과학
    • /
    • 제20권3호
    • /
    • pp.198-203
    • /
    • 2007
  • 수용액상에 존재하는 3-monochloropropane-1,2-diol (3-MCPD)의 LC-MS를 이용한 분석방법을 개발하였다. 수용액 시료에 수산화나트륨 용액을 첨가하여 강알칼리 상태를 유지시킨 후, 3-MCPD의 유도체화를 위하여 benzoyl chloride $25{\mu}L$을 넣어 직접 반응시켰다. 반응 후 유도체를 pentane으로 추출하여 LC-MS의 selected ion monitoring (SIM) 법으로 정량하였다. 분석결과 검량선은 $1.0-100{\mu}g/mL$ 농도범위에서 $r^2=0.992$의 상관관계 계수를 갖는 좋은 직선성을 나타내었으며, 검출한계는 $0.01{\mu}g/mL$ 이하였다. LC-MS에 의한 분석방법의 회수율은 92.3-98.0%이었다.

자동연속흐름-흡광광도법과 DNPH-LC법에 의한 먹는물 중 포름알데히드 정량분석 비교 (Comparison of ACFAS method and DNPH-LC method for quantitative analysis of formaldehyde in Drinking water)

  • 이건호;윤인철;김영관;김종철;최금종;이택수
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.827-836
    • /
    • 2013
  • Due to the stringent drinking water quality, formaldehyde will be included in Korean drinking water standard from year 2014. However, its standard analytical method has not yet been established. This study compares two analytical methods, DNPH-LC and ACFAS with respect to their analysis principles, Method Detection Limit (MDL), Limit Of Quantitation(LOQ), precision, accuracy, reproducibility, convenience, number of samples analyzed per hour and analysis cost. These methods measure absorption intensity at 360 nm by using HPLC after DNPH-derivatization (DNPH-LC) and at 410 nm by using Automated Continuous Flow Absorption Spectrophotometer (ACFAS), respectively. Reproducibility was tested by repeating the analysis 7 times using a standard solution for each method. For DNPH-LC method, MDL was $0.5{\mu}g/L$, LOQ was $1.58{\mu}g/L$ with standard deviation of $0.16{\mu}g/L$. For ACFAS method, they were $0.27{\mu}g/L$, $0.85{\mu}g/L$L with standard deviation of $0.09{\mu}g/L$, respectively. Both methods satisfied the requirement set by the Korean drinking water quality standard. Complexity of sample pretreatment procedure for DNPH-LC method may cause large error and, consequently, the analytical result will depend on the level of skill of analyst. In contrast, ACFAS method which used only one reagent equipped with an automated injection device showed little analytical error. It costs about $5.00 and $1.00 for one sample to analyze by the DNPH-LC method and the ACFAS method, respectively. Compared to the DNPH-LC method, ACFAS method provided more reliable analytical results. In terms of convenience, easiness and analytical cost, ACFAS method was demonstrated to be superior to the DNPH-LC method. The results of this study suggested that the ACFAS method could be adapted as a proper method for determining formaldehyde content in drinking water.

시료 농축 후 액-액-추출과 GC-MS를 이용한 염소 소독 음용수중 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone(MX)의정량 분석 (Quantitative determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in chlorinated drinking water using sample enrichment followed by liquid-liquid extraction and GC-MS)

  • 김희갑;송병열
    • 분석과학
    • /
    • 제29권1호
    • /
    • pp.29-34
    • /
    • 2016
  • 염소로 소독된 음용수에서 수백 ng/L의 농도까지 검출되는 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone(MX)를 시료 농축 후 액-액 추출(LLE), 메틸 유도체화 및 GC-MS로 정량 분석하였다. 4 L의 물 시료를 감압회전증발기를 사용해 30 ℃에서 0.4 L로 농축하였다. 물 중의 MX는 ethyl acetate(100 mL × 2)를 용매로 사용하여 추출하였으며, 추출액 중 MX는 10 % H2SO4 in methanol로 methyl 유도체를 만들었다. MX의 회수율은 73.8 %이었으며, 이는 수지 흡착법의 38.1 %보다 높았다. 정량한계와 반복성(RSD)은 각각 10 ng/L와 2.2 %로 추정되었다. 이 결과는 시간이 더 많이 소요되는 수지 흡착법의 대체 방법으로 LLE가 사용될 수 있다는 것을 보여 주었다.

HPLC에 의한 aflatoxin 분석법에 관한 연구 형광 및 자외선 흡광 검출의 비교 (Determination of Aflatoxins Using High-Performance Liquid Chromatography and Fluorescence or UV Absorbence Detection)

  • 김종규;강회양;민경진
    • 한국환경보건학회지
    • /
    • 제22권1호
    • /
    • pp.36-44
    • /
    • 1996
  • A comparison was made of two detection methods(UV absorbence detection and fluorescence detection with pre-column derivatization, with trifluoroacetic acid) coupled with HPLC for the simultaneous determination of aflatoxin $B_1, B_2, G_1$ and $G_2$. A good separation of the four aflatoxins was achieved on a reversed-phase $C_{18}$ column (30 cm x 3.9 mm) with methanol-acetonitrile-water(20+20+60) for absorbence detection or acetonitrile-water(25+75) for fluorescence detection at the flow rate of 1.0 ml/min. The calibration graphs were linear over the ranges 100 ppb-1 ppm for $B_1/G_1$ and 30~300 ppb for $B_2/G_1$ with absorbence detection, and 1~500 ppb for $B_1/G_1$ and 0.3~150 ppb for $B_2/G_2$ with fluorescence detection. The correlation coefficients were greater than 0.94 and 0.99 for absorbance detection and for fluorescence detection, respectively. The detection limit was 100 ng for $B_1/G_1$ and 30 ng for $B_2/G_2$ with absorbence detection, and 1 ng for $B_1/G_1$ and 0.3 ng for $B_2/G_2$ with fluorescence detection. Recovery rates of aflatoxin $B_1, B_2, G_1$ and $G_2$ added to yeast-extract sucrose broth medium were 66.6%, 59.4%, 67.5% and 59.2%, respectively, for absorbence detection and 82.9%, 71.5%, 80.0% and 69.3%, respectively, for fluorescence detection. The four aflatoxins in culture medium were quantitatively detected by the two methods. The aflatoxins in the rice sample were not detected the absorbence detection method, but were below 10 ppb using the fluorescence detection method. Analysis of aflatoxins by both the absorbence and fluorescence methods coupled with HPLC showed acceptable linearity and good recovery. The absorbence detection was less timeconsuming and safer for treatment. The fluorescence detection was more elective and sensitive though elevated $B_1$ and $G_1$ contents were determined from the TFA-induced conversion of $B_1$ to $B_{2a}$ and $G_1$ to $G_{2a}$.

  • PDF