• Title/Summary/Keyword: depth radiation

Search Result 637, Processing Time 0.035 seconds

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

An Ultrastructural Study on the Parotid Acinar Cells of X-irradiated Rats (X-선 조사를 받은 흰쥐 귀밑샘 샘포의 미세구조)

  • Yang, Nam-Gil;Park, In-Kyu;Ahn, E-Tay;Ko, Jeong-Sik;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.1
    • /
    • pp.28-40
    • /
    • 1994
  • Xerostomia and xerophthalmia are delicate or serous side effects, occuring when the radiotherapy is administered to the head and neck cancer patient. It is known that the cause of the above side effect is radiosensitivity of serous cells. In this study, the ultrastructural features of the parotid glands of the X-irradiated rats were observed. Sprague-Dawley rats weighing 200-250g each were anesthetized with sodium thiopental, and placed on the Mitsubishi linear accelerator. Only the head and neck areas of animals were exposured at the distance of 80cm, within the area of $30X30cm$, in the depth of 1cm, with the speed of 200R/min. Total doses applied were 3,000R or 6,000R depending on the experimental groups. Animals were sacrificed on the 6th hour, 2nd day and 6th day after the irradiation. Parotid glands were fixed in the 2.5% glutaraldehyde-1.5% paraformaldehyde solution, and followed by refixation in the 1% osmium tetroxide solution. Dehydrated blocks were embedded in araldite mixture, and ultrathin sections were cut. Sections were contrasted with the solution of uranyl acetate and lead citrate, and observed with JEM 100 CX-II electron microscope. The results were as follows: 1. Normal parotid acinar cells are two types; the light and the dark acinar cells. The light acinar cell contains dense secretory granules, whereas dark acinar cells contains granules of medium density with some darker spots within them, or other cells contain granules of medium density with darker rims. 2. Six hours after the irradiation, many acinar cells were degenerated showing variable stages of cytolytic bodies, light bodies, or dense degenerations. Within the acinar cell, Golgi apparatus and granular endoplasmic reticula were most severely altered elements. Granules showed more contrasting densities and irregularities. 3. Two days after the irradiation, some cytolytic bodies, and focal lucent degeneration of cytoplasm, and fine granular alteration of cytoplasmic matrix were pronounced. But other elements including secretory granules are rather looked unlatered. 4. Six days after the irradiation, most severe alterations were seen. Many intracellular canaliculi (or secretion figures), quanta of cytoplasm containing secretion antecedants, severely irregular luminal border, and again contrasting density of secretory granules showing tigroid spots or dense rims were noted. And myoepithelial degenerations were observed not uncommonly. 5. Irregular densities of secretory granules were interpreted as abnormal components of protein or carbohydrate portion are synthesized or abnormally metabolized under severe X-irradiation. 6. Myoepithelial degeneration and related alteration of nerve endings, etc., were suggested as the other causes of xerostomia following X-irradiation. 7. It is requested that radiation doses should be arranged, considering in mind not only the sensitivity of acinar cells but also the myoepithelial and neural functions.

  • PDF

10 MV X-ray Beam Dosimetry by Water and White Polystyrene Phantom (물과 백색폴리스티렌 팬텀에 의한 10 MV X-선 빔 선량계측)

  • Kim, Jong-Eon;Cha, Byung-Youl;Kang, Sang-Sik;Park, Ji-Koon;Sin, Jeong-Wook;Kim, So-Yeong;Jo, Seong-Ho;Son, Dae-Woong;Choi, Chi-Won;Park, Chang-Hee;Yoon, Chun-Sil;Lee, Jong-Duk;Park, Byung-Do
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.83-87
    • /
    • 2008
  • The purpose of this study is to get the correction factor to correct the measured values of the absolute absorbed dose proportional to the water equivalent depth. The measurement conditions in white polystyrene and water phantoms for 10MV X-ray beam are that the distance of source to center of ionization chamber is fixed at SAD 100 cm, the field sizes are $10{\times}10\;cm^2$, $20{\times}20\;cm^2$ and the depths are 2.3 cm, 5 cm, 10 cm, and 15 cm, respectively. The mean value of ionization was obtained by three times measurements in each field size and depths after delivering 100 MU from linear accelerator with output of 400 MU per min to the two phantoms. The correction factor and the percentage deviation in TPR were obtained below 0.97% and 0.53%, respectively. Therefore, we can get high accuracy by using the correction factor and the percentage deviation in TPR in measuring the absolute absorbed dose with the solid water equivalent phantom.

  • PDF

Investigation of Various Radiation Proton Energy Effect on n, p Type Silicon by Positron Annihilation Method (양전자 소멸 측정법으로 양성자 조사에너지 변화에 대한 n, p형 실리콘 구조 특성)

  • Lee, Chong Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.341-347
    • /
    • 2013
  • The n-type and p-type silicon samples were exposed by 40.0, 3.98 MeV proton beams ranging between 0 to $20.0{\times}10^{13}protons/cm^2$. Coincidence Doppler Broadening Positron Annihilation Spectroscopy (CDBPAS) were applied to study of defect characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the gamma spectrum and the total counts of whole gamma spectrum. The S-parameter values strongly depend on the irradiated proton beam that indicated the defects generate more, rather than the energy intensity. 40 MeV irradiated proton beam in the n-type silicon at $20.0{\times}10^{13}protons/cm^2$ was larger defects than 3.98 MeV irradiated proton beam. It was analysis between the proton irradiation beams and the proton intensities of the irradiation. Because of the Bragg peak, SRIM results shows mainly in a certain depth of the sample to form the defect by the proton irradiation, rather than the defects to appear for the entire sample.

Impact of Seawater Inflow on the Temperature and Salinity in Shihwa Lake, Korea (배수갑문 운용에 따른 시화호의 수온과 염분 변화)

  • Choi, Jung-Hoon;Kim, Kye-Young;Hong, Dae-Byuk
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.541-552
    • /
    • 2000
  • The variations of physical properties due to inflow of seawater by sluice gates operation were observed in Shihwa Lake. The distributions of salinity and temperature were investigated at 11 stations during February, 1997 to July, 1998. The salinity of water mass in Shihwa Lake before gate operation was ranged below 15psu and strong stratification due to inflow of seawater was observed at the depth of 11 m. In July 1997, temperature difference of 10^{\circ}C$ was occurred between the surface and bottom water due to strong solar radiation. During October 1997 to February 1998, inversion of temperature distribution, which the temperature of bottom water was higher than that of surface water, was observed. In July 1997, temperature, salinity, current speed and current direction were investigated by RCM-7 at St.3 for 56 days. When sea water was intruded in Shihwa Lake, the symmetric distribution of temperature and salinity was observed and it seems to be resulted from inflow of seawater with low temperature and high salinity. After January 1998, salinity of Shihwa Lake was increased over 30psu due to continuous gate operation and the stratification was weakened.

  • PDF

Sensitivity Analysis of Surface Reflectance Retrieved from 6SV LUT for Each Channel of KOMPSAT-3/3A (KOMPSAT-3/3A 채널별 6SV 조견표의 지표반사도 민감도 분석)

  • Jung, Daeseong;Jin, Donghyun;Seong, Noh-Hun;Lee, Kyeong-Sang;Seo, Minji;Choi, Sungwon;Sim, Suyoung;Han, Kyung-Soo;Kim, Bo-Ram
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.785-791
    • /
    • 2020
  • The radiance measured from satellite has noise due to atmospheric effect. Atmospheric correction is the process of calculating surface reflectance by removing atmospheric effect and surface reflectance is calculated by the Radiative Transfer Model (RTM)-based Look-Up Table (LUT). In general, studies using a LUT make LUT for each channel with the same atmospheric and geometric conditions. However, atmospheric effect of atmospheric factors do not react sensitively in the same channel. In this study, the LUT for each channel of Korea Multi-Purpose SATellite (KOMPSAT)-3/3A was made under the same atmospheric·geometric conditions. And, the accuracy of the LUT was verified by using the simulated Top of Atmosphere radiation and surface reflectance in the RTM. As a result, the relative error of the surface reflectance in the blue channel that sensitive to the aerosol optical depth was 81.14% at the maximum, and 42.67% in the NIR (Near Infrared) channel.

Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation (Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.443-450
    • /
    • 2018
  • The Geant 4 simulated the linear accelerator (VARIAN CLINAC) based on the previously implemented BEAMnrC data, using the head structure of the linear accelerator. In the 10 MV photon flux, Geant4 was compared with the measured value of the percentage of the deep dose and the lateral dose of the water phantom. In order to apply the dose calculation to the body part, the actual patient's lung area was scanned at 5 mm intervals. Geant4 dose distributions were obtained by irradiating 10 MV photons at the irradiation field ($5{\times}5cm^2$) and SAD 100 cm of the water phantom. This result is difficult to measure the dose absorbed in the actual lung of the patient so the doses by the treatment planning system were compared. The deep dose curve measured by water phantom and the deep dose curve calculated by Geant4 were well within ${\pm}3%$ of most depths except the build-up area. However, at the 5 cm and 20 cm sites, 2.95% and 2.87% were somewhat higher in the calculation of the dose using Geant4. These two points were confirmed by the geometry file of Genat4, and it was found that the dose was increased because thoracic spine and sternum were located. In cone beam CT, the dose distribution error of the lungs was similar within 3%. Therefore, if the contour map of the dose can be directly expressed in the DICOM file when calculating the dose using Geant4, the clinical application of Geant4 will be used variously.

Structural Design Requirements and Safety Evaluation Criteria of the Spent Nuclear Fuel Disposal Canister for Deep Geological Deposition (심지층 고준위폐기물 처분용기에 대한 설계요구조건 및 구조안전성 평가기준)

  • Kwon, Young-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.229-238
    • /
    • 2007
  • In this paper, structural design requirements and safety evaluation criteria of the spent nuclear fuel disposal canister are studied for deep geological deposition. Since the spent nuclear fuel disposal canister emits high temperature heats and much radiation, its careful treatment is required. For that, a long term(usually 10,000 years) safe repository for the spent nuclear fuel disposal canister should be secured. Usually this repository is expected to locate at a depth of 500m underground. The canister which is designed for the spent nuclear fuel disposal in a deep repository in the crystalline bedrock is a solid structure with cast iron insert, corrosion resistant overpack and lid and bottom, and entails an evenly distributed load of hydrostatic pressure from underground water and high pressure from swelling of bentonite buffer. Hence, the canister must be designed to withstand these high pressure loads. If the canister is not designed for all possible external loads combinations, structural defects such as plastic deformations, cracks, and buckling etc. may occur in the canister during depositing it in the deep repository. Therefore, various structural analyses must be performed to predict these structural problems like plastic deformations, cracks, and buckling. Structural safety evaluation criteria of the canister are studied and defined for the validity of the canister design prior to the structural analysis of the canister. And structural design requirements(variables) which affect the structural safety evaluation criteria should be discussed and defined clearly. Hence this paper presents the structural design requirements(variables) and safety evaluation criteria of the spent nuclear fuel disposal canister.

  • PDF

A study of geothermal heat dump for solar collectors overheat protection (태양열 집열관 과열방지를 위한 지중열교환기 연구)

  • Hwang, Hyun-Chang;Chi, Ri-Guang;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.616-622
    • /
    • 2016
  • The heating load using solar hot water is lower in summer than in the other seasons. This decreased heating load leads to the overheating solar collectors and related components. To prevent overheating of the solar collectors, air cooling and shading shields were used. On the other hand, it requires additional mechanical components, and reduces the system reliability. The geothermal heat dump system to release the high temperature heat (over $150^{\circ}C$) transferred from the heat pipe solar collectors was investigated in the present study. Research on the heat dump to cool the solar collector is rare. Therefore, the present study was carried out to collect possible data of a geothermal heat dump to cool the solar collector. A helical type geothermal heat exchanger was buried at a 1.2m depth. Experimentally and numerically, the geothermal heat dump was investigated in terms of the effects of parameters, such as the quantity of solar radiation, aperture area of the collector and the mass flow rate. A pipe length of 50m on the geothermal heat exchanger was suitable with a 0.33 kg/s flow rate. The water reservoir was a possible co-operation solution linked to the geothermal heat exchanger.

Plasma Etching Characteristics of Sapphire Substrate using $BCl_3$-based Inductively Coupled Plasma ($BCl_3$ 계열 유도결합 플라즈마를 이용한 사파이어 기판의 식각 특성)

  • Kim, Dong-Pyo;Woo, Jong-Chang;Um, Doo-Seng;Yang, Xue;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.363-363
    • /
    • 2008
  • The development of dry etching process for sapphire wafer with plasma has been key issues for the opto-electric devices. The challenges are increasing control and obtaining low plasma induced-damage because an unwanted scattering of radiation is caused by the spatial disorder of pattern and variation of surface roughness. The plasma-induced damages during plasma etching process can be classified as impurity contamination of residual etch products or bonding disruption in lattice due to charged particle bombardment. Therefor, fine pattern technology with low damaged etching process and high etch rate are urgently needed. Until now, there are a lot of reports on the etching of sapphire wafer with using $Cl_2$/Ar, $BCl_3$/Ar, HBr/Ar and so on [1]. However, the etch behavior of sapphire wafer have investigated with variation of only one parameter while other parameters are fixed. In this study, we investigated the effect of pressure and other parameters on the etch rate and the selectivity. We selected $BCl_3$ as an etch ant because $BCl_3$ plasmas are widely used in etching process of oxide materials. In plasma, the $BCl_3$ molecule can be dissociated into B radical, $B^+$ ion, Cl radical and $Cl^+$ ion. However, the $BCl_3$ molecule can be dissociated into B radical or $B^+$ ion easier than Cl radical or $Cl^+$ ion. First, we evaluated the etch behaviors of sapphire wafer in $BCl_3$/additive gases (Ar, $N_2,Cl_2$) gases. The behavior of etch rate of sapphire substrate was monitored as a function of additive gas ratio to $BCl_3$ based plasma, total flow rate, r.f. power, d.c. bias under different pressures of 5 mTorr, 10 mTorr, 20 mTorr and 30 mTorr. The etch rates of sapphire wafer, $SiO_2$ and PR were measured with using alpha step surface profiler. In order to understand the changes of radicals, volume density of Cl, B radical and BCl molecule were investigated with optical emission spectroscopy (OES). The chemical states of $Al_2O_3$ thin films were studied with energy dispersive X-ray (EDX) and depth profile anlysis of auger electron spectroscopy (AES). The enhancement of sapphire substrate can be explained by the reactive ion etching mechanism with the competition of the formation of volatile $AlCl_3$, $Al_2Cl_6$ or $BOCl_3$ and the sputter effect by energetic ions.

  • PDF