Therapeutic results and safety of postoperative radiotherapy for keloid after repeated Cesarean section in immediate postpartum period

  • Kim, Ju-Ree;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • 제30권2호
    • /
    • pp.49-52
    • /
    • 2012
  • Purpose: To evaluate the effectiveness and safety of postoperative radiotherapy for the treatment of keloid scars administered immediately after Cesarean section. Materials and Methods: A total of 26 postpartum patients with confirmed keloids resulting from previous Cesarean sections received either 12 or 15 Gy radiotherapy. The radiotherapy was divided into three 6 MeV electron beam fractions administered during the postpartum period immediately following the final Cesarean section. To evaluate ovarian safety, designated doses of radiation were estimated at the calculated depth of the ovaries using a solid plate phantom and an ionization chamber with the same lead cutout as was used for the treatment of Cesarean section operative scars and a tissue equivalent bolus. Results: In total, the control rate was 77% (20 patients), while six (23%) developed focally elevated keloids (ranging from 0.5 to 2 cm in length) in the middle of the primary abdominal scar. Five patients experienced mild hyperpigmentation. Nonetheless, most patients (96%) were satisfied with the treatment results. The estimated percentage of the applied radiation doses that reached the calculated depth of the ovaries ranged from 0.0033% to 0.0062%. Conclusion: When administered during the immediate postpartum period, postoperative electron beam radiotherapy for repeated Cesarean section scars is generally safe and produces good cosmetic results with minimal toxicity.

Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging

  • Song, Hankyeol;Kang, In Soo;Kim, Kyu Bom;Park, Chanwoo;Baek, Min Kyu;Lee, Seongyeon;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2646-2651
    • /
    • 2021
  • A rectangular-shaped PET system with an adjustable gantry (AGPET) has been developed for imaging small animals. The AGPET system employs a new depth of interaction (DOI) method using a depth dependent reflector patterns and a new digital time pickoff method based on the pulse reconstruction method. To evaluate the performance of the AGPET, timing resolution, intrinsic spatial resolution and point source images were acquired. The timing resolution and intrinsic spatial resolution were measured using two detector modules and Na-22 gamma source. The PET images were acquired in two field of view (FOV) sizes, 30 mm and 90 mm, to demonstrate the characteristic of the AGPET. As a result of in the experiment results, the timing resolution was 0.9 ns using the pulse reconstruction method based on the bi-exponential model. The intrinsic spatial resolution was an average of 1.7 mm and the spatial resolution of PET images after DOI correction was 2.08 mm and 2.25 mm at the centers of 30 mm and 90 mm FOV, respectively. The results show that the proposed AGPET system provided higher sensitivity and resolution for small animal imaging.

방사선관리구역내의 종사자 및 임상실습 학생의 개인피폭선량 비교 분석 (Analysis of Individual Exposure Dose of Workers and Clinical Practice Students in Radiation Management Area)

  • 이주아
    • 한국콘텐츠학회논문지
    • /
    • 제17권11호
    • /
    • pp.383-388
    • /
    • 2017
  • 방사선구역내의 종사자 간 선량 비교 및 동일한 구역 내에서 임상실습에 임하는 학생들의 선량을 추가하여 비교함으로써 방사선방어의 최적화 구현에 대한 기초자료를 제공하고자 하였다. 연구 대상은 2016년 1월부터 동년 12월까지 C대학병원 방사선 관리구역에 재직 중인 방사선관계종사자 121명과 방사선작업종사자 36명, 그리고 8주간의 임상실습을 이수한 121명의 학생을 비교 대상으로 하였다. 방사선관계종사자와 작업종사자 간의 심부 및 표층 선량은 관계종사자가 각각 $.7440{\pm}1.676mSv$$.7753{\pm}1.730mSv$로 가장 높게 나타났으며, 통계적으로 매우 유의하였다(p<.01). 세 그룹 간에는 심부 선량의 경우 임상실습학생이 $.143{\pm}.136mSv$로 가장 높게 나타났고, 표층 선량에서도 $.1513{\pm}.139mSv$로 가장 높게 나타났으며, 작업종사자가 두 경우 모두 가장 낮았다. 그룹 간의 평균의 차이는 통계적으로 매우 유의하였다(p<.01). 결론적으로 ALARA(As Low As Reasonably Achievable)원칙에 의거 철저한 관리가 필요하며, 특히 방사선안전관리의 사각지대에 놓여 있는 임상실습 학생에 대한 체계적인 피폭선량 관리가 필요할 것으로 사료된다.

직장암의 수술 후 방사선 치료 시 국소 재발의 임상 병리적 예후 인자 (The Clinicopathological Factors That Determine a Local Recurrence of Rectal Cancers That Have Been Treated with Surgery and Chemoradiotherapy)

  • 최철원;김민석;이승숙;류성렬;조철구;양광모;유형준;서영석;황대용;문선미;김미숙
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.255-262
    • /
    • 2006
  • 목 적: 진행된 직장암의 수술 후 보조적 방사선 치료를 시행한 환자에서 국소 재발한 군의 병리학적 예후 인자를 규명함으로써 향후 치료 방침의 결정에 도움이 되고자 하였다. 대상 및 방법: 1993년 2월부터 2001년 12월까지 원자력의학원에서 수술을 시행한 후 병기 3기 이상으로 방사선치료 및 항암 요법을 시행 받은 직장암 환자 110명을 대상으로 검체를 모두 조사하여 면역조직화학검사가 가능한 총 54명을 대상으로 하였다. 이중 국소전이가 발견된 군이 14명, 발견되지 않은 군이 40명이었다. 이들의 조직 검체를 대상으로 종양의 침윤 깊이, 종양의 조직학적 등급, 임파절 침윤 여부, 혈관 침윤 여부, 신경 침윤 여부 등의 병리적인 특징 및 p53, Ki-67, c-erb, ezrin, c-met, phospho-S6K, S100A4, HIF-1 alpha의 다양한 암 유전자의 발현양상을 단변량 분석 및 다변량 분석, hierarchical clustering 분석 기법을 사용하여 치료 후 예후와 관련된 인자를 찾았다. 결 과: 병리학적 예후 인자 중 단변량 분석상 종양 침윤 깊이, 종양의 등급, 혈관 침범이 의미 있었고 다변량 분석상 침윤의 깊이가 5.5 mm 이하, 혈관 침윤이 없는 경우가 국소 재발이 낮은 군이었다. 면역조직화학검사 결과의 단변량 분석상 c-met 양성, HIF-1 alpha 양성이 국소 재발률이 높은 예후 인자였고 다변량 분석상 c-met이 의미 있는 예후 인자였다. Hierarchical clustering을 통해서 조사한 결과 HIF-1 alpha, c-met 및 종양 침윤 깊이가 국소재발과 관련된 인자로써 국소 재발을 한 군의 71.4%가 3가지 인자 중 2개 이상을 가지고 있는 반면 국소 재발을 하지 않은 군에서는 27.5%가 2개 이상을 가지고 있었다. 결 론: 국소적으로 진행되어 방사선 치료를 시행해야 하는 직장암 환자군 중에서 HIF-1 alpha 양성, c-met 양성, 종양 침윤 깊이 5.5 mm 이상의 병리학적 예후 인자를 두 개 이상 가지는 환자는 국소 재발의 가능성이 높다. 이러한 인자가 방사선치료 저항군의 지표로써 유용한지에 대한 전향적 연구가 향후 필요할 것이다.

편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰 (Study of photon beam quality tool at magnetic field change in bending magnet)

  • 김정호;유세종;박명철;배석환;김기진
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산 (Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays)

  • 김기환;오영기;신교철;김진기;정동혁;김정기;조문준;김선영
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.221-225
    • /
    • 2007
  • 움직이는 자기장을 이용한 팬텀 속 선량 변조에 관한 몬테칼로 계산을 수행하였다. 본 연구의 목적은 빔 축을 따라 이동하는 횡 자기장을 이용하여 특정감이 영역에 균일한 선량을 얻는 것이다. 이를 위해 두 가지 구성 즉, 깊이 방향으로 일정한 속도 그리고 점차 감소하는 속도를 가지는 자기장에 대해 깊이 선량율을 구하였다. 연속적 움직임에 대한 근사로서 단계별 이동과 시간인자를 도입하였다. 위치별 정지한 자기장 대한 김이 선량율 자료에 최소제곱법을 적용하여 자기장 위치에 따른 최적의 시간인자를 구하였다. 몬테칼로 계산결과를 통하여 자기장의 속도를 변화시킴으로써 평탄한 선량 분포를 얻을 수 있음을 확인하였다. 이 때 3 T 자기장 세기에 대한 계산결과 평탄 영역의 선량은 자기장이 없을 때에 비해 약 10.1% 증가하는 것으로 나타났다.

  • PDF

Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율 (Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays)

  • 김원식;하석호;황선태;오장진;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 1987
  • X-선 target 으로 부터 water phantom($30{\times}30{\times}30cm^3$) 표면까지 1m이고 이 지점에서 비임 크기가 $5cm{\phi},\;10cm{\phi},\;15cm{\phi}$인 경우 phantom 표면으로 부터 X-선 중심축을 따라 깊이 2.5cm의 기준점으로 부터깊이 20cm까지 2.5cm 간격으로 깊이-선량 백분율, P(%)을 추정하였다. 사용된 X-선 인가전압 및 전류는 $150{\sim}250kV$ 및 5 mA 이었고 물속 흡수선량률, $\dot{D}_w$은 NE 2571 공동전리함의 조사선량 교정인자 $N_x$로부터 구한 공기 kerma 고정인자 $N_k$를 이용하여 결정하였다. 기준조사선량룰 $\dot{X}_c$은 Exradin A-2공동 전리함을 일본 ETL로부터 교정하여 X-선 선질을 ETL 교정선질과 같도록 반가층을 결정한 후에 측정되었다. 한편, 흡수선량 및 깊이-선량 백분율 측정의 정확도를 검증하기 위해 phantom 속 깊이 5 cm되는 교정점에서 물속흡수선량률, $\dot{D}_w$$N_k$로부터 산출한 값과 Burlin의 일반화된 공동이론을 이용하여 계산한 값을 비교해 보았으며, $N_k$로부터 결정된 깊이-선량 백분율 P(%)을 BJR Suppl. 로부터 구한 값과 비교해 본 결과는 좋은 일치를 보였다.

  • PDF

고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구 (Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer)

  • 박용철;박종호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰 (Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator)

  • 문언철;김현진;김영석
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF