천흘수 초대형 부유식 해양규조물의 유탄성 응답해석 (Analysis of Hydroelastic Responses for Very Large Floating Structures with a Shallow Draft)

  • 신현경
    • 한국해양공학회지
    • /
    • 제14권2호
    • /
    • pp.53-59
    • /
    • 2000
  • A numerical method to predict responses of very large floating structures in wave is suggested using source-dipole distribution method. The deflection of the plate is calculated by the finite element method in terms of rigidity matrix of each node. The calculated results for a plate are compared with the experimental ones.

  • PDF

고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구 (Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws)

  • 김정기;최영민;이형힉;허원주
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.237-244
    • /
    • 1996
  • 목적 : 의료용 선형가속기의 Independent Collimator는 현재 광범위하게 사용되고 있다. 그러나 방사선량의 계산과 MU(Monitor Unit)의 계산에 사용되는 모든 기본 자료는 대칭 조사면를 기준으로 작성되었기 때문에 independent collimator를 사용한 비대칭적인 조사면의 경우 현재 사용하고 있는 계산 방식을 그대로 적용함에 무리가 있을 것으로 생각된다. 따라서 이러한 의문에 대한 체계적이고 과학적인 검토가 필요할 것으로 사료되어 본 연구를 진행하였다. 대상 및 방법 :본 연구는 Dual Photon Beam(6MV와 15MV)을 산출(産出)하는 선형가속기(Linac 1800, Varian Co)에서 collimator 사용시 산란 방사선의 총채로 표현되어지는 field size factor, beam qualify에 영향을 미치는 HVL와 PDD를 조사하였다. 먼저 field size factor는 water phantom(WP 600C Wellhofer, Germany)내의 Dmax에서 field size $3{\times}3cm$에서 $35{\times}35cm$까지의 방사선량의 변화를 square field로 $1cm^2$씩 증가시켜 가며 0.6cc ion chamber(NE 2571)로 측정하였다. Beam quality는 100cm SSD(source-surface distance)에서 $5{\times}5$, $10{\times}10$, $15{\times}15$$20{\times}20cm$ field size로 0, 3 및 10cm off-axis distance와 dmax 4, 10, 15 및 20cm의 깊이에서 측정하였다. Dose distribution을 분석하기 위하여 film densitometer와 water phantom(IC 10 ion chamber)을 사용, $10{\times}10cm$ field size에서 5, 10 및 15cm의 off-axis distance까지의 방사선량의 분포를 관찰하고 대칭 방사선 조사면와 비교 분석하여 실제 isodose 분포에 미치는 영향을 관찰하였다. 결과: 1) Relative field size factor는 중심 축에서 off-axis lateral distance에 따라 다양하게 변화하였는데 6MV X-선의 경우 최대 $3.1\%$, 15MV X-선의 경우 최대 $5\%$까지의 변화를 보였다. 이때 off-axis factor를 구하여 교정을 하였을 경우 중심 축의 field size factor와 거의 유사한 값에 도달할 수 있었다. 2) Beam qualify의 변화를 관찰하기 위한 실험에서 HVL는 off-axis distance가 멀어질수록 감소하였고 PDD도 off-axis distance가 멀어지고 측정 깊이가 깊어질수록 감소되는 현상을 보였다. 통상적인 방사선 치료시에 이용되는 $5{\times}5cm$ 이상의 field size와 15cm 이내의 깊이에서는 3cm 와 l0cm의 off-axis에서 6MV X-선은 평균 $0.5\%$$2\%$, 15MV X선은 $0.4\%$$1.4\%$의 감소 현상을 보여 큰 편차를 관찰할 수 없었다. 3) Isodose distribution은 off-axis distance가 멀어질수록 depth dose의 증가치가 감소되었으며 특히 central axis의 가장자리 부위에서는 isodose curve의 위축이 확연하였다. 결론 : Independent collimator를 사용하여 비대칭 방사선 치료를 할 경우 MU의 계산은 off-axis factor와 PDD 보정이 필수적이며 임상적으로는 중심 축에서의 과소조사에 대한 정밀한 주의가 필요할 것으로 사료된다.

  • PDF

Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF

Improved accuracy in periodontal pocket depth measurement using optical coherence tomography

  • Kim, Sul-Hee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Jun-Min;Yi, Won-Jin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제47권1호
    • /
    • pp.13-19
    • /
    • 2017
  • Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was $3.10{\pm}0.15mm$, $4.11{\pm}0.17mm$, $5.09{\pm}0.17mm$, and $6.05{\pm}0.21mm$ for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

Linear Energy Transfer Dependence Correction of Spread-Out Bragg Peak Measured by EBT3 Film for Dynamically Scanned Proton Beams

  • Lee, Moonhee;Ahn, Sunghwan;Cheon, Wonjoong;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.135-144
    • /
    • 2020
  • Purpose: Gafchromic films for proton dosimetry are dependent on linear energy transfers (LETs), resulting in dose underestimation for high LETs. Despite efforts to resolve this problem for single-energy beams, there remains a need to do so for multi-energy beams. Here, a bimolecular reaction model was applied to correct the under-response of spread-out Bragg peaks (SOBPs). Methods: For depth-dose measurements, a Gafchromic EBT3 film was positioned in water perpendicular to the ground. The gantry was rotated at 15° to avoid disturbances in the beam path. A set of films was exposed to a uniformly scanned 112-MeV pristine proton beam with six different dose intensities, ranging from 0.373 to 4.865 Gy, at a 2-cm depth. Another set of films was irradiated with SOBPs with maximum energies of 110, 150, and 190 MeV having modulation widths of 5.39, 4.27, and 5.34 cm, respectively. The correction function was obtained using 150.8-MeV SOBP data. The LET of the SOBP was then analytically calculated. Finally, the model was validated for a uniform cubic dose distribution and compared with multilayered ionization chamber data. Results: The dose error in the plateau region was within 4% when normalized with the maximum dose. The discrepancy of the range was <1 mm for all measured energies. The highest errors occurred at 70 MeV owing to the steep gradient with the narrowest Bragg peak. Conclusions: With bimolecular model-based correction, an EBT3 film can be used to accurately verify the depth dose of scanned proton beams and could potentially be used to evaluate the depth-dose distribution for patient plans.

환부 부착용 거즈의 Bolus Effect에 관할 고찰 (The Consideration of Bolus Effects of Games Attached on Lesion area)

  • 박주영;주상규;박용철;한영이;신은혁;박영환
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.51-56
    • /
    • 2004
  • 상처 보호를 위해 환부에 부착하는 거즈가 체표 선량(skin dose) 및 심부 선량(최고 선량)에 미치는 영향을 조사하여 표재성 종양의 방사선 치료 시 bolus의 대용으로 이용 가능한지 알아보고자 한다. 4MV Photon(CL600C, Barian, US)을 대상으로 폴리스틸렌 팬톰(25(W) X25(L) X 40(H) cm3)과 평형 평판형 전리함(Markus chamber, PTW, US)을 이용하여 환부 부착용 거즈의 두께와 재질을 변화시키면서 체표선량 및 심부선량을 측정하였다. 거즈의 두께는 5장, 10장, 15장을 대상으로 하였으며 재질은 순수 거즈와 바셀린을 도포한 거즈를 구분하여 측정하였다. 또한 bolus 사용 시와 비교하기 위해 동일한 조건에서 bolus 0.5, 1.0 cm을 대상으로 표면선량 및 심부 선량을 측정하여 비교 분석하였다. 최고 선량점을 기준으로 체표 선량은 open beam일 경우 $34.78\%$, 거즈 5장, 10장, 15장 부착 시 각각 69, 80, $91\%$로 거즈 두께와 함께 증가하였다. 또한 바셀린 거즈 5장, 10장, 15장 부착시 각각 98, 100, $98\%$의 결과치가 나왔다. 한편, 0.5 cm bolus와 5장의 거즈를 조합하였을 때의 체표선량은 $96\%$로 측정되었다. 방사선 치료 시 체표에 부착한 거즈는 산란체로 작용하여 심부 선량의 변화 없이 체표선량을 증가시키는데 크게 기여하였다. 그러나 체표에 최고 선량을 조사하기 위해서는 많은 두께(약 15장 이상)의 거즈를 필요로 한다. 또한 바셀린 및 bolus의 사용으로 이러한 목적은 쉽게 얻을 수 있지만 심부 선량의 변화로 선량 계산 시 이에 대한 보정이 필요하다. 따라서 측정치를 기초로 목표 체표 선량과 환자의 setup효율성을 고려한 적절한 조건을 찾는다면 bolus대용으로 거즈를 이용하는 것이 치료의 효율성을 높이는데 도움이 될 것으로 사료된다.

  • PDF

안구차폐체 제작에 필요한 안면부 3차원 정보 구현의 기초연구 (Preliminary Research on the Implementation of Information of Human Facial Part Required for the 3D Printing of Eye Shield)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.955-960
    • /
    • 2019
  • 전산화단층검사는 많은 방사선을 받을 수 있으며, 한 명의 환자에서 반복적으로 시행되는 경우가 위험도는 매우 높다. 어린이의 경우에 방사선에 의한 암 발생률이 더 높다고 보고하고 있다. 3D 프린트는 여러 분야에 적용하기 위해서 연구되고 있으며, 여러 응용 분야중 방사선 차폐체 제작 및 재료에 대한 연구가 최근 진행되고 있다. 3D 프린터의 목적은 기존의 판넬 형태의 차폐체를 대체하고 인체의 형태를 따라 맞춤형 제작을 하는 것이 최종 목적이기 때문에 3D 프린터에 입력할 3차원정보처리에 대한 연구도 매우 중요하다. 본 연구에서는 스테레오 비전의 깊이지도(depth map) 생성 기술을 이용하여 환자 맞춤형 안구차폐체 제작의 전단계인 인체표면의 3차원 데이터를 계산하고 활용 가능성을 연구하고자 하였다. 알려진 3차원 정보처리의 방법들에 비해서 비교적 간단한 방법으로 제안된 결과 안면부 3차원 정보추출을 위한 최소한의 정보가 추출되었다. 본 연구의 결과는 자연광을 적용한 스테레오영상의 장점과 한계점을 제공하였고 향후 안구 차폐체 제작을 위한 기초자료가 될 것으로 판단한다.

의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가 (Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator)

  • 이동운;정강교;신귀순;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.177-184
    • /
    • 2016
  • 최근 선형가속기를 이용한 방사선치료는 세기조절방사선치료, 정위적방사선치료 등이 널리 사용되고 있다. 이러한 방사선 치료기법은 일반적으로 역방향치료계획을 사용함으로써 소조사면을 제외하기 어렵다. 그러므로 소조사면의 선량특성에 관한 정확한 측정이 필요하다. 따라서 유효체적이 서로 다른 검출기를 이용하여 소조사면에 대한 깊이선량백분율, 빔측면도, 그리고 선량출력계수를 측정하여 각 검출기의 선량특성 평가하고자 하였다. 실험 결과 X-선 6 MV에너지에 대한 빔선질($PDD_{20}/PDD_{10}$)은 $10{\times}10cm^2$에서 Diode 검출기는 Pinpoint 검출기에 비해 2.4%로 높았다. 모든 조사면에서 유효체적이 작은 Diode 검출기가 다른 검출기들과 50%이상 작은 반음영을 보여 공간분해능이 우수한 것으로 평가되었다. 출력선량계수는 조사면 $2{\times}2cm^2$에서 Semiflex 검출기 다른 검출기에 비해 2%정도 적게 측정되기 시작해서 조사면 $1{\times}1cm^2$에서는 20%정도 차이를 보이며 유효성이 없는 것으로 판단된다. 조사면 $1{\times}1cm^2$에서 Diode 검출기와 Pinpoint 검출기의 측정값은 13%정도 차이를 보였다. 조사면 $3{\times}3cm^2$이하에서는 검출기의 유효체적에 따른 출력선량계수의 차이가 크므로 가능한 유효체적이 작은 검출기를 사용해야 될 것으로 사료된다.

이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가 (Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC))

  • 김애란;서재혁;신헌주;박형욱;이기웅;이재춘;김신욱;김지나;박혜리;이희관;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.223-228
    • /
    • 2015
  • 이중으로 집중된 미세 다엽콜리메이터(Double-focused micro Multileaf Collimator: ${\mu}MLC$)는 보통의 다엽콜리메이터(Multileaf Collimator: MLC)에 비하여 조사면 가장자리 부분의 선량을 급격하게 줄여준다. 이러한 특성 때문에, 미세 다엽 콜리메이터는 정위적 방사선 수술과 치료(Stereotactic Radio-Surgery/RadioTtherapy, SRS/SRT)에 사용되어 왔다. 우리는 Elekta Synergy 선형가속기에 이중으로 집중된 동적 미세 다엽콜리메이터(Double-focused Dynamic micro-Multileaf Collimator: DMLC)를 부착하여 선량학적 특성을 평가하였다. 본 연구에서는, 필름(GafChromic EBT2 film), EDGE 다이오드 검출기, 3차원 물 팬텀을 이용하였다. 깊이선량백분율(Percent Depth Dose, PDD), 엽 투과도(leaf leakage), 반그림자(Penumbra)를 측정하였고, 모든 데이터들은 6MV 광자선으로 측정하였다. 그 결과, DMLC가 1% 이내의 투과도를 갖는것을 확인할 수 있었다. DMLC는 이중으로 집중 되는 구조를 가졌기 때문에 반 그림자가 조사야 크기에 대하여 독립적인 것을 확인하였다. 본 연구에서는 DMLC의 선량학적 특성을 바탕으로, Elekta Synergy에 부착된 DMLC의 적용 가능성을 증명하였다.

Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정 (High Energy Electron Dosimetry by Alanine/ESR Spectroscopy)

  • 추성실
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.85-92
    • /
    • 1989
  • 물질에 방사선을 조사시키면 구성원자 또는 분자의 일부분이 전리되며 특수한 유기화합물은 장기간 free radical상태로 존재하고 그 밀도는 조사된 방사선량에 비례한다. Free radical상태의 물질에 마이크로파와 같은 전자파를 투과시키면 free radicl된 전자의 고유진동과 일치된 전자파를 흡수하는 전자스핀공명(Electron Spin Resonance)이 일어나며 흡수된 전파의 강도를 측정함으로서 조사된 방사선량을 추측할 수 있다. ESR를 이용한 free radical dosimeter로서 가장 잘 알려진 물질이 아미노산 alanine이므로 이것과 파라핀 $10\%$를 혼합하여 $0.4\times1cm$의 alanine dosimeter를 제작하였다. 측정 방법은 방사선 흡수선량을 직접 측정할 수 있도록 조직등가인 물 팬텀과 방수된 Alanine dosimeter holder를 제작하고 의료용 선형가속기에서 발생되는 $6\~21$ MeV전자선을 조사하면서 최대 흡수 선량과 깊이에 따른 선량분포를 측정하였다. 전자선 조사선량은 1 Gy에 60 Gy까지의 방사선 치료선량 범위를 선택하였으며 측정결과 전자선량 증가에 따라 ESR신호의 진폭이 선형비례적으로 증가하였다. 그러나 전자선량이 4 Gy이하에서는 alanine dosimeter의 선량 균일성 이 $\pm2\~4\%$ (표준편차)의 오차가 있었으며 4 Gy이상에서는 $\pm1\%$ 이하의 오차를 나타냄으로서 환자에 대한 전자선 조사량 범위인 1Gy에서 60Gy까지의 흡수선량을 정확히 측정할 수 있었다. 측정한 결과 전자선 에너지 12 MeV이하에서는 전리상으로 측정 계산된 선량과 일치하였지만 15 MeV이상에서는 표면에서 깊이 2cm까지의 흡수선량이 약$2\~5\%$가 높았다. 이와 같은 현상은 의료용 선형가속기의 전자선 방출구에 장착된 산란판과 조사면을 조정하는 cone에 의하여 발생되는 저 에너지 산란전자선이 alanine dosimeter에 측정된 것으로서 에너지가 증가될수록 오염 정도가 증가되었다. 본 실험을 통하여 지금까지 고에너지 전자선량계측에서 전리상에 의한 전기량 측정과 산란선이 없는 단일 에너지로만 간주하여 계산하였던 전자선 흡수선량 측정방법을 직접 흡수선량 측정이 가능한 Alanine/ESR dosimetry로서 교정하는 것이 바람직하다고 생각한다.

  • PDF