• Title/Summary/Keyword: depth calibration

Search Result 236, Processing Time 0.029 seconds

Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography (주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.309-316
    • /
    • 2007
  • We demonstrate the wavelength swept source and signal processing for the frequency domain optical coherence tomography. The laser output performance is improved by using a semiconductor optical amplifier with a booster amplifier. The laser generates 14 mW of average power of which wavelength shift in the lasing spectral shape is compensated. Adopting a Fabry-Perot etalon and digital signal processing, the broadening of the beat frequency due to the variance of wavelength-sweep-velocity is calibrated. The optical coherence tomography system shows 154.4 kHz of axial scanning speed, 0.95mm of depth range, and $12{\pm}0.37{\mu}m$ of axial resolution.

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Comparison of Air Kerma and Absorbed Dose to Water Based Protocols for High Energy Photon Beams: Theoretical and Experimental Study

  • Shin, Dong-Oh;Kim, Seong-Hoon;Seo, Won-Seop;Park, Sung-Yong;Park, Jin-Ho;Kang, Jin-Oh;Hong, Seong-Eon;Ahn, Hee-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.241-243
    • /
    • 2002
  • New types of protocols have been recently in development, all based on an absorbed dose-to-water with the aim of improving the accuracy of measurements of absorbed dose to water. IAEA TRS-277, the air-kerma standard-based present protocol, and IAEA TRS-398 and AAPM TG-51, the absorbed dose-to-water standard-based new one, were studied and compared theoretically and experimentally for photon beams of 6, 10, and 15 MV. NE 2571 and 3 Farmer types of ionization chambers in widely commercial use were used to determine an absorbed dose to water at the reference depth in water. Two different kinds of calibration factors were given respectively for every chamber calibrated in $\^$60/CO gamma ray beams from a Korean Secondary Standard Dosimetry Laboratory (KFDA). This work shows that there is around 1 % of difference of absorbed doses measured between two different types of calibration systems owing to different physical parameters and reference conditions used. We hope this work to help form the basis on development of new type of protocol in Korea.

  • PDF

Effects of Pile Diameter on the Plugging Rate and Bearing Capacity of Open -Ended Piles (말뚝직경이 재단말뚝의 폐색정도와 지지력에 미치는 영향)

  • Baek, Gyu-Ho;Kim, Yeong-Sang;Lee, Seung-Rae
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.85-94
    • /
    • 1996
  • Model pile tests, using a calibration chamber in which the stress state and the relative density can be controlled, were performed in order to study the effects of pile diameter on the plugging rate and bearing capacity of open-ended pile. The model piles used in the test series were devised so that the bearing capacity of an open-ended pile could be measured out into three components. The test results showed that fully plugging depth of an open -ended pile increased with increase in pile diameter and soil density. Moreover, it was found that unit plug capacity decreased with increase in pile diameter, though the penetration ratio or plugging rate of piles was constant. However, the existing formulae for estimation of plug capacity give plug capacity which is constant or increased with increase in pile diameter, when penetration ratio or plugging rate of piles is equal. Thus, it is proposed that the effect of pile diameter as well as plugging rate on bearing capacity of pile must be considered in plug capacity estimation.

  • PDF

External Validation of a Gastric Cancer Nomogram Derived from a Large-volume Center Using Dataset from a Medium-volume Center

  • Kim, Pyeong Su;Lee, Kyung-Muk;Han, Dong-Seok;Yoo, Moon-Won;Han, Hye Seung;Yang, Han-Kwang;Bang, Ho Yoon
    • Journal of Gastric Cancer
    • /
    • v.17 no.3
    • /
    • pp.204-211
    • /
    • 2017
  • Purpose: Recently, a nomogram predicting overall survival after gastric resection was developed and externally validated in Korea and Japan. However, this gastric cancer nomogram is derived from large-volume centers, and the applicability of the nomogram in smaller centers must be proven. The purpose of this study is to externally validate the gastric cancer nomogram using a dataset from a medium-volume center in Korea. Materials and Methods: We retrospectively analyzed 610 patients who underwent radical gastrectomy for gastric cancer from August 1, 2005 to December 31, 2011. Age, sex, number of metastatic lymph nodes (LNs), number of examined LNs, depth of invasion, and location of the tumor were investigated as variables for validation of the nomogram. Both discrimination and calibration of the nomogram were evaluated. Results: The discrimination was evaluated using Harrell's C-index. The Harrell's C-index was 0.83 and the discrimination of the gastric cancer nomogram was appropriate. Regarding calibration, the 95% confidence interval of predicted survival appeared to be on the ideal reference line except in the poorest survival group. However, we observed a tendency for actual survival to be constantly higher than predicted survival in this cohort. Conclusions: Although the discrimination power was good, actual survival was slightly higher than that predicted by the nomogram. This phenomenon might be explained by elongated life span in the recent patient cohort due to advances in adjuvant chemotherapy and improved nutritional status. Future gastric cancer nomograms should consider elongated life span with the passage of time.

Simulator of Underwater Navigation

  • Waz, Mariusz
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.333-335
    • /
    • 2006
  • Position of surface objects can be fixed in many ways. The most popular radionavigational systems, including satellite systems, make possible obtaining nearly continuous and very precise ship's position. However, under the water application of radionavigational systems is impossible. Underwater navigation requires other tools and solutions then these encountered in surface and air navigation. In underwater environment vehicles and submarines, operate that have to possess alternative navigational systems. Underwater vehicles, in order to perform their tasks require accurate information about their own, current position. At present, they are equipped with inertial navigational systems (INS). Accuracy of INS is very high but in relatively short periods. Position error is directly proportional to time of working of the system. The basic feature of INS is its autonomy and passivity. This characteristic mainly decides that INS is broadly used on submarines and other underwater vehicles. However, due to previously mentioned shortcoming i.e. gradually increasing position error, periodical calibration of the system is necessary. The simplest calibration method is surface or nearly surface application of GPS system. Another solution, which does not require interruption of performed task and emergence on the surface, is application of comparative navigation technique. Information about surrounding environment of the ship, obtained e.g. by means sonic depth finder or board sonar, and comparing it with accessible pattern can be used in order to fix ship's position. The article presents a structure and a description of working of underwater vehicle navigation system simulator. The simulator works on the basis of comparative navigation methods which exploit in turn digital images of echograms and sonograms. The additional option of the simulator is ability to robust estimation of measurements. One can do it in order to increase accuracy of position fixed with comparative navigation methods application. The simulator can be a basis to build future underwater navigation system.

  • PDF

Catadioptric Omnidirectional Stereo Imaging System and Reconstruction of 3-dimensional Coordinates (Catadioptric 전방향 스테레오 영상시스템 및 3차원 좌표 복원)

  • Kim, Soon-Cheol;Yi, Soo-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4108-4114
    • /
    • 2015
  • An image acquisition by using an optical mirror is called as a catadioptric method. The catadioptric imaging method is generally used for acquisition of 360-degree all directional visual information in an image. An exemplar omnidirectional optical mirror is the bowl-shaped hyperbolic mirror. In this paper, a single camera omnidirectional stereo imaging method is studied with an additional concave lens. It is possible to obtain 3 dimensional coordinates of environmental objects from the omnidirectional stereo image by matching the stereo image having different view points. The omnidirectional stereo imaging system in this paper is cost-effective and relatively easy for correspondence matching because of consistent camera intrinsic parameters in the stereo image. The parameters of the imaging system are extracted through 3-step calibration and the performance for 3-dimensional coordinates reconstruction is verified through experiments in this paper. Measurable range of the proposed imaging system is also presented by depth-resolution analysis.

An automatic rotating annular flume for cohesive sediment erosion experiments: Calibration and preliminary results

  • Steven Figueroa;Minwoo Son
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.319-319
    • /
    • 2023
  • Flows of water in the environment (e.g. in a river or estuary) generally occur in complex conditions. This complexity can hinder a general understanding of flows and their related sedimentary processes, such as erosion and deposition. To gain insight in simplified, controlled conditions, hydraulic flumes are a popular type of laboratory research equipment. Linear flumes use pumps to recirculation water. This isn't appropriate for the investigation of cohesive sediments as pumps can break fragile cohesive sediment flocs. To overcome this limitation, the rotating annular flume (RAF) was developed. While not having pumps, a side-effect is that unwanted secondary circulations can occur. To counteract this, the top and bottom lid rotate in opposite directions. Furthermore, a larger flume is considered better as it has less curvature and secondary circulation. While only a few RAFs exist, they are important for theoretical research which often underlies numerical models. Many of the first-generation of RAFs have come into disrepair. As new measurement techniques and models become available, there is still a need to research cohesive sediment erosion and deposition in facilities such as a RAF. New RAFs also can have the advantage of being automatic instead of manually operated, thus improving data quality. To further advance our understanding of cohesive sediment erosion and deposition processes, a large, automatic RAF (1.72 m radius, 0.495 m channel depth, 0.275 m channel width) has been constructed at the Hydraulic Laboratory at Chungnam National University (CNU), Korea. The RAF has the ability to simulate both unidirectional (river) and bidirectional (tide) flows with supporting instrumentation for measuring turbulence, bed shear stress, suspended sediment concentraiton, floc size, bed level, and bed density. Here we present the current status and future prospect of the CNU RAF. In the future, calibration of the rotation rate with bed shear stress and experiments with unidirectional and bidirectional flow using cohesive kaolinite are expected. Preliminary results indicate that the CNU RAF is a valuable tool for fundamental cohesive sediment transport research.

  • PDF

Enhancing streamflow prediction skill of WRF-Hydro-CROCUS with DDS calibration over the mountainous basin.

  • Mehboob, Muhammad Shafqat;Lee, Jaehyeong;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.137-137
    • /
    • 2021
  • In this study we aimed to enhance streamflow prediction skill of a land-surface hydrological model, WRF-Hydro, over one of the snow dominated catchments lies in Himalayan mountainous range, Astore. To assess the response of the Himalayan river flows to climate change is complex due to multiple contributors: precipitation, snow, and glacier melt. WRF-Hydro model with default glacier module lacks generating streamflow in summer period but recently developed WRF-Hydro-CROCUS model overcomes this issue by melting snow/ice from the glaciers. We showed that by implementing WRF-Hydro-CROCUS model over Astore the results were significantly improved in comparison to WRF-Hydro with default glacier module. To constraint the model with the observed streamflow we chose 17 sensitive parameters of WRF-Hydro, which include groundwater parameters, surface runoff parameters, channel parameters, soil parameters, vegetation parameters and snowmelt parameters. We used Dynamically Dimensioned Search (DDS) method to calibrate the daily streamflow with the Nash-Sutcliffe efficiency (NSE) being greater than 0.7 both in calibration (2009-2010) and validation (2011-2013) period. Based on the number of iterations per parameter, we found that the parameters related to channel and runoff process are most sensitive to streamflow. The attempts to address the responses of the streamflows to climate change are still very weak and vague especially northwest Himalayan Part of Pakistan and this study is one of a few successful applications of process-based land-surface hydrologic model over this mountainous region of UIB that can be utilized to have an in-depth understanding of hydrological responses of climate change.

  • PDF

Measurement and Analysis of Bed Shear Stresses in Compound Open Channels using the Preston Tube (프레스톤튜브를 이용한 복단면 하도의 하상전단응력 측정 및 분석)

  • Lee, Du Han;Kim, Myounghwan;Kim, Won;Seo, Il Won
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.207-215
    • /
    • 2017
  • Hydraulic issues such as flow resistance, side wall correction, sediment, erosion and deposition, and channel design have close relation with distribution of bed shear stresses but the measurement of the distribution of bed shear stresses is not easy. In this study the Preston tube which makes possible relatively simple measurement of bed shear stresses is used to analyze the characteristics of bed shear distribution in compound open channels with different depth ratio. The Preston tubes are made and calibrated to develop the calibration formula and then they are applied to measure bed shear stress distribution in 5 cases depth ratio condition of compound channels. The results are compared with former experiment data, and characteristics of bed shear stress distributions are studied with different channel scales and Reynolds numbers. Although bed shear distributions with depth ratio show overall agreement with former studies, some differences are verified in bed shear variation, formation of inflection point in main channel, and distribution near floodplain junction which are due to high Reynolds number. Through the study applicability of the Preston tubes are also verified and characteristics of bed shear distribution in compound channels are suggested with Reynolds number and depth ratio.