• Title/Summary/Keyword: dental setting

Search Result 259, Processing Time 0.029 seconds

Tobacco Cessation in India: How Can Oral Health Professionals Contribute?

  • Oberoi, Sukhvinder Singh;Sharma, Gaurav;Nagpal, Archana;Oberoi, Avneet
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2383-2391
    • /
    • 2014
  • Tobacco use is described as the single most preventable cause of morbidity and mortality globally, with the World Bank predicting over 450 million tobacco-related deaths in the next fifty years. In India, the proportion of all deaths that can be attributed to tobacco use is expected to rise from 1.4% in 1990 to 13.3% in 2020 of which smoking alone will cause about 930,000 adult deaths by 2010. Many studies have shown that counseling from a health professional is an effective method of helping patients quit the tobacco habit. Tobacco cessation needs to be urgently expanded by training health professionals in providing routine clinical interventions, increasing availability and subsidies of pharmacotherapy, developing wide-reaching strategies such as quitlines, and costeffective strategies, including group interventions. The WHO Framework Convention on Tobacco Control (FCTC) emphasizes the vital contribution of participation of health professional bodies, as well as training and healthcare institutions in tobacco control efforts. Dentists can play an important role in helping patients quit using tobacco. One of the key strategies to reduce tobacco-related morbidity and mortality is to encourage the involvement of health professionals in tobacco-use prevention and cessation counselling. The dental office is an ideal setting for tobacco cessation services since preventive treatment services, oral screening, and patient education have always been a large part of the dental practice.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

The Effects of Work Value and Major Satisfaction of Dental Hygiene Students on Career Decision Self-Efficacy (치위생 전공 대학생의 직업 가치관과 전공만족도가 진로 결정 자기효능감에 미치는 영향)

  • Ji, Jae-Hoon;Heo, Seong-Eun
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.6
    • /
    • pp.183-193
    • /
    • 2019
  • This study aimed to investigate the effects of work value and major satisfaction of dental hygiene students on career decision self-efficacy. A survey was conducted on dental hygiene students of a university in B area, and data were analyzed by using SPSS 24.0 and AMOS 24.0 program. The extrinsic work value had a positive effect on the career decision self-efficacy directly and a negative effect on the major satisfaction, a mediator. The intrinsic work value had a positive effect on the major satisfaction directly. Additionally, extrinsic and intrinsic work values had an indirect effect on career decision self-efficacy through major satisfaction. The results suggest that it is necessary to form desirable work values and increase the level of major satisfaction in order to improve career decision self-efficacy and could be used as fundamental data for setting a career and education direction of dental hygiene students.

Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis (티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

Effect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing (시멘트 공간이 적층 가공으로 제작한 지르코니아 하부구조물의 변연 및 내면 적합도에 미치는 영향)

  • Ji-Won Min;Se-Yeon Kim;Jae-Hong Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Purpose: The goal of this study was to determine the clinical acceptability of various cement space settings for the marginal and internal fit of a zirconia core manufactured using additive manufacturing. Methods: The maxillary right incisor served as the master model. After scanning the maxillary right incisor with a dental 3D (three-dimensional) scanner, the stereo lithography file was created using different cement space settings of 40, 120, and 200 ㎛ using computer-aided design software (Dental System 2018; 3Shape). The marginal and internal fit of the 3 groups were determined using the silicon replica technique. Measurement points were divided into the following three categories: margin, axial wall, and incisal. To ensure more accurate measurements, these three measurement points were divided into 8 points. The Shapiro-Wilk, one-way ANOVA, and Tukey's honestly significant difference test (for all tests α=0.05) were the statistical analyses that were included in the study. Results: The CS (cement space)-200 group had better marginal and internal fit than the CS-40 and CS-120 groups, and there were statistically significant differences at the marginal and incisal points, except for the axial wall points. CS-200 group, both marginal and internal fit were within 120 ㎛, which is the clinically acceptable value. Conclusion: This study suggests that a 200 ㎛ cement space setting is ideal for optimal marginal and internal fit of 3D-printed ceramic crowns.

Occlusal Adjustment in the Natural and Restored Dentition (고정성 보철물 및 자연치열을 위한 교합조정)

  • Ahn, Seung-Geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2003
  • When treating the occlusion the dentist must ensure that patients do not develop an occlusal awareness or neurosis after therapy. This means that after treatment patients should not be conscious of the dentition at rest, in occlusion, or during function. Butactually this goal is not easy to reach in daily practice. The dental technician works with rigid casts and dies that do not move. The dentist must use fixed prostheses that have been made in a laboratory setting in a clinical environment that is significantly different. In this article relativey easy cast adjustment technique which can decrease the time necessary to clinically adjust the occlusion of newly fabricated fixed prostheses, and actual occlusal equilibration technique for natural and restored dentition will be discussed.

A Study on the Orthodontic Activator for Mal-Occulsion (하악전돌 교정을 위한 Activator 개선에 관한 연구)

  • Shin, Moo-Hak
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.31-34
    • /
    • 1983
  • We were usually make use of Viggo activator for orthodontic the state prognathous. But, it inconvenient for use because demend of long time until orthodontic use finished for restoration of everybody production and function(esthetic, mastication, phonetic). So, we were enough effect obtained for everybody function with this improve. 1. Improves Viggo activator inconvenience of insertion and remove. 2. It can be set with considering of functional and esthetics. 3. Get a orthodontics effect without lonf period. 4. Have no convenience to mastication at setting with occlusal correction at anytime.

  • PDF

Calcium Phosphate Cement Reinforced with Chopped High Performance Polyethylene Fiber.

  • Hirayama, S.;Ikemi, T.;Tsujimoto, Y.;Yamazaki, M.;Chow, L.C.;Takagi, S.;Antonucci, J.M.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.567.1-567
    • /
    • 2001
  • A self-setting calcium phosphate cement (CPC), consisting of tetracalcium phosphate (TTCP) and dicalcium phosphate anhydrous (DCP A), reacts with water and hardens fast (30 min) to form hydroxyapatite (HA) under physiological conditions as the final product. Although this CPC is finding increasing use as a biomaterial, it is presently limited to low stress bearing applications because of its relatively low strength and highly brittle nature. Recently the mechanical properties of CPC reinforced with chopped carbon fiber have been reported.

  • PDF

Successful repair of a partially transected endotracheal tube with Dermabond surgical adhesive during a Lefort osteotomy: a case report

  • Daniel Ahn;Tuan-Hsing Loh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.2
    • /
    • pp.117-119
    • /
    • 2023
  • Damage to the endotracheal tube (ETT) during oral and maxillofacial surgeries is a rare but serious intraoperative complication. Herein, we present a case of a partially damaged ETT that was repaired using Dermabond surgical adhesive (Ethicon, Sommerville, NJ, USA) during a Lefort osteotomy. Dermabond surgical adhesive can be a simple and viable tool to repair partially transected ETTs where ETT exchange carries a high risk of airway loss. Our case adds to one of the several techniques for managing damaged ETT in an intraoperative setting.

Effect of Some Characteristics of Service Provider on Trust and Loyalty in Services Setting (서비스제공자의 특성이 신뢰와 충성도에 미치는 영향)

  • Choi, Chul-Jae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.293-310
    • /
    • 2012
  • The purpose of this paper is to explain and identify how services offer-related characteristics of services providers such as service competence, reliability, and responsiveness have an effect on cognitive trust and customization characteristics of services providers has influences on affective trust. And it is to explain and identify how cognitive trust has an effects on affective trust and loyalty, and how affective trust has influence on loyalty in services setting such as apparel services of search attribute, hair services of experience attribute, and dental services of credence attribute. A survey study was conducted to collect the data with consumers who have experience purchase or search on services in apparel services, hair services, and dental services. Analysis of structural equation modeling with AMOS 18 and SPSS win 19.0 was performed to test the research hypothesis. The results of the study are as follows: First, responsiveness characteristics of service providers has an effect on cognitive trust, which in turn influences on affective trust. But there was on effect on customer loyalty by cognitive trust and affective trust in apparel service setting. Second, service competence characteristics and reliability characteristics of service providers have effect on cognitive trust, and customization characteristics of service providers has influences on affective trust, and then both of them, in turn, was effect on customer loyalty in hair service setting. Third, reliability characteristics of service providers has effects on cognitive trust and customization characteristics of service providers has influences on affective trust, and then cognitive trust has effects on customer loyalty, but there was no effects on affective trust by customer loyalty.