• 제목/요약/키워드: dental prosthetic materials

검색결과 137건 처리시간 0.027초

Oral rehabilitation of Papillon-Lefèvre syndrome patients by dental implants: a systematic review

  • Atarbashi-Moghadam, Fazele;Atarbashi-Moghadam, Saede;Kazemifard, Setare;Sijanivandi, Soran;Namdari, Mahshid
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.220-227
    • /
    • 2020
  • Objectives: Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disorder. These patients lose their teeth at a young age and are in need of prosthetic rehabilitation. The aim of this systematic review was to assess the success of dental implant placement in these patients. Materials and Methods: An electronic search was performed in PubMed Central, Scopus, and Web of Science using the keyword "Papillon-Lefèvre syndrome" AND "dental implant" OR "prosthodontics". Articles reporting implant placement in patients with PLS until July 2019 were included. Results: Assessment of the included 11 articles reporting 15 cases showed 136 implant placements in these patients. Implant failure occurred in 3 patients (20 implants). The peri-implantitis and failure rate was higher in the maxilla. Meta-analysis showed the probability of failure to be 7% (95% confidence interval [CI] 0%-31%) for maxillary implants and 2% (95% CI 0%-9%) for mandibular implants. The follow-up time ranged between 1 and 20 years. Healing after bone graft and implant placement in these patients was uneventful. Conclusion: Dental implants may be a viable treatment option for PLS patients. Implantation can help preserve alveolar bone if the patients' immunological and growing conditions are well-considered and proper oral hygiene and compliance with the maintenance program are continued.

Two-body wear behavior of human enamel versus monolithic zirconia, lithium disilicate, ceramometal and composite resin

  • Habib, Syed Rashid;Alotaibi, Abdulaziz;Al Hazza, Nawaf;Allam, Yasser;AlGhazi, Mohammad
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.23-31
    • /
    • 2019
  • PURPOSE. To investigate and compare the surface roughness (SR), weight and height of monolithic zirconia (MZ), ceramometal (CM), lithium disilicate glass ceramic (LD), composite resin (CR), and their antagonistic human teeth enamel. MATERIALS AND METHODS. 32 disc shaped specimens for the four test materials (n=8) and 32 premolars were prepared and randomly divided. SR, weight and height of the materials and the antagonist enamel were recorded before and after subjecting the specimens to 240,000 wear-cycles ($49N/0.8Hz/5^{\circ}C/50^{\circ}C$). SR, height, weight, and digital microscopic qualitative evaluation were measured. RESULTS. CM ($0.23+0.08{\mu}m$) and LD ($0.68+0.16{\mu}m$) exhibited the least and highest mean difference in the SR, respectively. ANOVA revealed significance (P=.001) between the materials for the SR. Paired T-Test showed significance (P<.05) for the pre- and post- SR for all the materials. For the antagonistic enamel, no significance (P=.987) was found between the groups. However, the pre- and post- SR values of all the enamel groups were significant (P<.05). Wear cycles had significant effect on enamel weight loss against all the materials (P<.05). CR and MZ showed the lowest and highest height loss of 0.14 mm and 0.46 mm, respectively. CONCLUSION. MZ and CM are more resistant to SR against the enamel than LD and CR. Enamel worn against test materials showed similar SR. Significant variations in SR values for the tested materials (MZ, LD, CM, and CR) against the enamel were found. Wear simulation significantly affected the enamel weight loss against all the materials, and enamel antagonist against MZ and CM showed more height loss.

나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가 (Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis)

  • 정재헌;손미경;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.301-309
    • /
    • 2015
  • 목적: 이 연구의 목적은 지대주 나사 잔여 전부하 비율과 시멘트 파손유무 평가를 통해 나사 시멘트 유지형 임플란트 보철물(screw- and cement-retained implant prosthesis: SCP)의 임상적 수행 능력을 알아보는 것이다. 재료 및 방법: 구치부 부분 무치악 환자들을 대상으로 임플란트가 식립되었으며 3 - 6개월의 치유기간 후 SCP임플란트 보철물이 장착되었다. 추적관찰을 통해 임플란트의 생존율이 평가되고 보철물 성공률도 평가되었다. SCP 보철물의 나사 잔여 전부하 비율 및 시멘트 파손 비율이 측정되었다. 결과: 20명의 환자로부터 21개의 SCP보철물(43개의 임플란트)이 최대 64개월까지 관찰되었다. 관찰기간(평균 34개월) 동안 골융합에 실패한 임플란트는 하나도 없었다. 지대주, 나사, 도재 혹은 보철물 프레임 파절이나 나사 풀림 등은 없었으므로 보철물 성공율은 100%였다. SCP 보철물의 나사 잔여 전부하 비율은 97.61% (${\pm}16.29$), 그리고 시멘트 파손비율은 9.5%이었다. 결론: 본 실험의 한계 내에서, 나사 풀림과 시멘트 파손이란 관점에서 SCP 디자인의 임플란트 보철물은 양호한 단기 임상 결과를 보였다.

지상보수교육강좌 1 - 상악동저 거상술을 동반한 임프란트 동시 식립의 예지성 평가; 측방접근술과 치조정접근술의 비교 (Predictability of simultaneous implant placement with sinus floor elevation in the severely atrophic posterior maxillae ; Comparison of lateral and trans-crestal approaches)

  • 김영욱;금윤선;손효정;이장렬;김현철;이상철
    • 대한치과의사협회지
    • /
    • 제48권3호
    • /
    • pp.205-217
    • /
    • 2010
  • Purpose The aim of this study is to evaluate the survival rates and analyze the stability of lateral approach and trans-crestal approach for maxillary sinus floor elevation of simultaneous implant placement. Materials and method 407 patients who have been treated in LivingWell dental hospital between 2003 to 2009 were selected. Lateral window technique, osteotome technique and sinus drill technique were used for sinus floor elevation procedure. A total of 714 implants-MP-1 HA coated implant(Tapered Screw $Vent^{TM}$, $Spline^{TM}$, Zimmer, USA), FBR surfaced implant(Pitt-$Easy^{TM}$, Oraltronics, Germany)-were placed in grafted maxillary sinus simultaneously. The autogenous bone or a combination with the allograft or alloplast was grafted into sinus. Sinus floor elevation was combined with vertical/horizontal onlay bone grafts to reconstruct the defect of alveolar ridge. Results The average preoperative height of the maxillary alveolar bone was 5.78mm(range: 0.4mm~12.5mm). 14 implants failed during the healing period(lateral approach: 4, trans-crestal approach: 10) and 3 implant failed after prosthetic loading(lateral approach: 2, trans-crestal approach: 1). The cumulative survival rate of implants after 6 years was 97.6%. Trans-crestal approach(97.4%) and lateral approach(97.9%) had similar survival rates. Conclusion The results indicate that the trans-crestal approach and lateral approach for maxillary sinus elevation is a acceptable method at atrophic maxillary posterior area.

디지털 덴티스트리의 전환과 치위생교육 도입의 필요성 (Transformation of digital dentistry and the need of introducing education in dental hygiene)

  • 고혜빈;서영주;원복연;오상환
    • 한국치위생학회지
    • /
    • 제22권6호
    • /
    • pp.467-475
    • /
    • 2022
  • Objectives: This study aimed to understand the definitions, types, and principles of computer-aided design/computer-aided manufacturing (CAD/CAM) and scanners due to the introduction of digital workflows. Methods: This study was based on information from the government's law and articles published in academic journals. Results: CAD/CAM is a technology that measures the shape three-dimensionally, saves it as data, designs it into the desired shape, and processes the product. Scanners, which are classified as intraoral and extraoral scanners, measure teeth and the intraoral environment three-dimensionally and convert them into three-dimensional (3D). A 3D printer is a machine that creates a 3D object by layering materials based on a 3D drawing. It can be classified into four types according to the method: extrusion, powder bonding, lamination, and photopolymerization methods. The most used 3D printer methods in dentistry are stereolithograhpy and digital light processing, and they are widely used in prosthetic, surgical, and orthodontic fields. Conclusions: As the dental system is digitized, it is expected that the government will classify the dental hygienist scope of work and the universities will reflect the curriculum; it is necessary to develop excellent dental hygienists, diversify the educational pathways, and establish policies to meet the needs of the increasing number of patients.

치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구 (The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry)

  • 이종화;박천만;송재상;임시덕;김재도;김병식;황인환;이성국
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Long-term evaluations of teeth and dental implants during dental maintenance period

  • Yoon, Da-Le;Kim, Yong-Gun;Cho, Jin-Hyun;Lee, Jae-Mok;Lee, Sang-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.224-231
    • /
    • 2017
  • PURPOSE. This study was designed to evaluate the teeth and dental implants during dental maintenance therapy over 3 years in different conditions after periodontal and dental prosthetic treatment. MATERIALS AND METHODS. 166 patients received maintenance therapy. 59 patients were treated with 2% minocycline-HCl ointment as local drug delivery (LDD) (L group) and 107 patients were treated without LDD (NL group). Clinical data was collected in maintenance period for evaluation. Patients were classified into groups depending on the application of LDD with maintenance therapy, the type of dental treatment before maintenance period (Pre-Tx), the frequency (F-MT), and regularity (R-MT) of maintenance therapy. RESULTS. The numbers of lost teeth (N-teeth, P=.003) and newly placed dental implants (N-implants, P=.022) are significantly different according to Pre-Tx. F-MT among patients who received surgical dental treatment before maintenance period showed statistical differences in N-teeth (P=.041), but not in N-implants (P=.564). All of the patients in L group showed high F-MT (F-MT1). In NL group, there were no statistical differences in N-teeth or N-implants according to F-MT or R-MT. In F-MT1 group, application of LDD made N-teeth significantly different from both Pre-Tx groups while no significant difference could be found in N-implant. Independent t-test and one-way ANOVA were selected for statistical analysis. CONCLUSION. The regular maintenance therapy and LDD can be effective for teeth during maintenance period. It is not only pharmacological efficacy in decreasing bacterial species that makes LDD a useful adjunct. Application of LDD also motivates patients to take adequate check-ups in the aspects of both frequency and regularity.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.