• Title/Summary/Keyword: dental prosthetic materials

Search Result 137, Processing Time 0.028 seconds

Dental students' clinical confidence in denture treatment after clinical experiences (의치진료 경험 후 치과대학 학생들의 임상진료능력에 대한 자기인식도)

  • Lee, Bora;Shim, June-Sung;Lee, Jae Hoon;Kim, Jong-Eun;Park, Ji-Man;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.185-192
    • /
    • 2020
  • Purpose: The purpose of this study is to investigate dental students' self-perception of clinical care ability after a denture treatment experience. Materials and methods: Of the 58 fourth-year students at the dental school in 2019, 50 students completed the questionnaire concerning their denture treatment session, including treatment planning and pre-prosthetic treatment (4 questions), clinical and laboratory procedures (20 questions), and students' opinions on clinical denture education (4 questions). Each question was answered on a five-point scale, of which points four and five, "agree" and "strongly agree" respectively, were classified as positive responses while points one and two, "disagree" and "strongly disagree" respectively, were classified as negative. Results: All the items on clinical and laboratory procedures received a positive response rate of over 60%, and the overall self-perception of the students appeared to be positive. However, the questions on the ability to perform denture treatment independently after graduation received only 48% of positive answer. Those on patient management, explanations of denture precautions, customized tray production, boxing, and work model production were answered with the highest positive response rate whereas those on treatment planning, final impression acquisition, and surveying, were the lowest in each session. Conclusion: The dental students with experience in denture treatment generally have a positive opinion of their clinical care ability, but further education may be necessary to improve their ability to treat their patients independently.

Effect of intra-crown cantilever on mechanical strength of internal conical joint type implant (치관 내 캔틸레버 양에 따른 내측 연결 형태 임플란트의 기계적 강도에 대한 연구)

  • Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Young-Chan;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.360-367
    • /
    • 2015
  • Purpose : The purpose of this study was to evaluate the effect of amount of cantilever in intra-crown according to implant fixture position on mechanical strength of internal conical joint type implant. Materials and Methods : Internal conical joint type implant fixture, abutment screw, abutment was connected and gold alloy prostheses were fabricated and cemented on abutment. For fatigue fracture test, the specimens were loaded to the 350 N, 2,000,000 cycle on 3, 4, 5, and 6 mm off-center of gold alloy prostheses. The fracture pattern of implant component was observed. Results : No fatigue fracture found on 3 and 4 mm group. But initial crack pattern found on 3 specimens of 4 mm group. Fatigue fracture found on all specimens of 5 mm group. But complete fracture was not observed. One specimen of 6 mm group fracture completely. Implant fixture fracture wax not observed. Conclusion : The mechanical failure of implant prostheses increased with the loading area farther from center of implant fixture. To reduce mechanical problem of internal joint type implant, surgical and prosthetic consideration is needed.

Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

  • de Almeida Cardoso, Mauricio;de Molon, Rafael Scaf;de Avila, Erica Dorigatti;Guedes, Fabio Pinto;Filho, Valter Antonio Ban Battilani;Filho, Leopoldino Capelozza;Correa, Marcio Aurelio;Filho, Hugo Nary
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-54
    • /
    • 2016
  • The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects.

digital art : The use of digital in diagnosis and counseling in anterior tooth esthetic treatment (디지털 아트 : 전치 심미 치료시 진단과 상담에 있어서의 디지털의 활용)

  • Shin, JunHyouk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.88-97
    • /
    • 2016
  • Aesthetics can be affected by the interest and the trend of the time. There are the limits of the equipment and materials required for the times, aesthetic case is also considered necessary to overcome them and will introduce the following case in accordance with the patients demands and circumstances. I hope the further development of CAD/CAM by taking over the things have done in the analogue by utilizing the latest technology that is thought to challenge the current limit itself is important. Digital has the advantages in various perspectives. Especially, I am very interested in as related to "digital communication." In particular, when utilizing the data using intra oral scanner can easily direct converse about prosthesis between the dentist and the dental technician through a software program Now, as the digital communication affects the integrity of the prosthesis directly, I had a expectation of a new era for the prosthetic and aesthetics. In this case report, I would like to introduce direct and real digital communication through the following 2 parts.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

The effect of repeated surface treatment of zirconia on its bond strength to resin cement

  • Maciel, Lucas Campagnaro;Amaral, Marina;Queiroz, Daher Antonio;Baroudi, Kusai;Silva-Concilio, Lais Regiane
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.291-298
    • /
    • 2020
  • PURPOSE. The aim of this study is to evaluate the influence of repeated surface treatments on wettability and surface roughness for zirconia surface and bond strength of zirconia-based ceramics to resin cement. MATERIALS AND METHODS. Seventy blocks (10 × 10 × 3 mm) of zirconia-based ceramics were fabricated and divided into two groups according to the surface treatments: (A) 110 ㎛ Al2O3 airborne-particle abrasion and (R) 110 ㎛ silica modified Al2O3 airborne-particle abrasion. At stage 2, each group was subdivided into 5 groups according to the surface retreatments: (a) 110 ㎛ Al2O3 airborne-particle abrasion, (r) 110 ㎛ silica modified Al2O3 airborne-particle abrasion, (D) diamond bur, (Da) diamond bur + 110 ㎛ Al2O3 airborne-particle abrasion, and (Dr) diamond bur + 110 ㎛ silica modified Al2O3 airborne-particle abrasion. Cylinders of self-adhesive resin cement were cemented onto each treated ceramic surface and subjected to micro-shear bond strength test. Additional specimens were prepared for roughness and wettability analyses. The data were subjected to t-test and One-way ANOVA followed by Tukey's post hoc test (α=.05). RESULTS. At stage 1, group R presented higher bond strength values than group A (P=.000). There was a statistically significant increase of bond strength at stage 2 for group A (P=.003). The diamond bur influenced the surface roughness, increasing the values (P=.023). Group R provided better wettability. Regardless of the applied surface treatment, most of failures were adhesive. CONCLUSION. The combination of application and reapplication of Rocatec Plus showed the best results of bond strength. Surface retreatment and recementation might be an indicated clinical strategy.

Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study

  • Kim, Seok-Gyu;Yun, Pil-Young;Park, Hyun-Sik;Shim, June-Sung;Hwang, Jung-Won;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • PURPOSE. The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12- month postloading period. MATERIALS AND METHODS. Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during oneyear postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test. RESULTS. Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P<.05). Periimplant marginal bone loss (T: $0.27{\pm}0.54$ mm, C: $0.40{\pm}0.55$ mm) and periodontal parameters showed no significant difference between the groups (P>.05). CONCLUSION. Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

Evaluation of sleep quality and stress response in patients requiring dental prosthetic treatment (치과보철치료를 요하는 환자에서의 수면질과 스트레스 반응 평가)

  • Jeon, Hye-Mi;Jung, Kyoung-Hwa;Choi, Na-Rae;Song, Jae-Min;Lee, So-Hyoun;Kim, So-Yeun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • Purpose: The purpose of this study is to investigate the stress response and sleep state of the new patients who visit the hospital for prosthodontic treatment due to tooth loss to make reference to further treatment direction. Materials and methods: Examinations, consultations, and surveys were conducted on 236 patients (94 males, 142 females, and 24-86 years old), who newly registered at the department of prosthodontics at Pusan national university hospital, for 2 years from 2018. The number of remaining teeth, edentulous arch, possibility of mastication, and future prosthetic treatment directions were recorded. The visual analogue scale (VAS), stress response inventory (SRI) and Insomnia severity index (ISI) were used as tools to measure patient's subjective discomfort, stress response, and sleep status. Results: Among the entire prosthodontic patient group, the average value of 'fatigue' was significantly higher among the 7 items of SRI, and the value of 'aggression' was significantly lower (P<.001). There are a significant difference between the edentulous and full dentition in the oral discomfort value measured by VAS (P=.004). In cases where less than 20 teeth remain, mastication is impossible, and patients who are planning treatment with removable prostheses, VAS value and 'depression' and 'fatigue' values in SRI were higher than those in the reverse case (P<.05). The patients showed severe level in VAS value have high value of 'tension', 'somatization', 'depression', 'fatigue'and 'frustration'in SRI than non-serious patients (P<.05). Clinical insomnia occurred in 11.4% of all patients, and women had significantly lower sleep quality than men (P=.044). Patients with insomnia showed significantly higher scores on the VAS value and all 7 SRI items than those of normal sleepers (P<.05). Conclusion: The new prosthetics had high 'fatigue' value among the 7 items of SRI. The oral condition, number of residual teeth and mastication function and clinical insomnia affected oral discomfort and the stress response.

A STUDY ON THE BOND STRENGTH OF REINFORCED INDIRECT COMPOSITE RESINS TO DENIAL ALLOYS (강화형 간접복합레진과 치과용 합금의 결합강도에 관한 연구)

  • Yoon, Dong-Joo;Shin, Sang-Wan;Lim, Ho-Nam;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.620-639
    • /
    • 1999
  • Indirect composite resins are used as an popular effective esthetic material in prosthetic dentistry, often with metallic substructure that provides support for restorations. Recently, new indirect composite resins as a substitute of ceramic have been developed. These resins provide good esthetics, with a wide range of hue and chroma. And the flexural strength of those is in the range of 120-150MPa, Which is higher than that of feldspathic Ceramic, and similar th that of Dicor. Although it has many merits, one of the major clinical problems of composite resins is the bond failure between metal and resin due to insufficient interfacial bond strength. The purpose of this study was to evaluate shear bond strength of the reinforced indirect composite resin to dental alloys. Three different composite resin systems($Artglass^{(R)},\;Sculpture^{(R)},\;Targis^{(R)}$) as test groups and ceramic($VMK\;68^{(R)}$) as control group were bonded to Ni-Cr-Be alloy($Rexillium\;III^{(R)}$) and gold alloy(Deva 4). All specimens were stored at $^37{\circ}C$ distilled water for 24 hours and the half of specimens were thermocycled 2000 times at temperature from $5^{\circ}C\;to\;60^{\circ}C$. The shear bond strengths of reinforced indirect composite resins to dental alloys were measured by using the universal testing machine, and modes of debonding were observed by stereoscope and scanning electron microscope. The results were as follows: 1 The shear bond strengths of reinforced indirect composite resins to dental alloys were approximately half those of ceramic to dental alloys(P<0.01). 2. There was no significant difference between the shear bond strength of several reinforced indirect composite resins to metal. 3. Alloy type did not affect on the shear bond strengths of resin to metal, but the shear bond strengths of ceramic to gold alloys were higher than those of ceramic to Ni-Cr alloys(P<0.05). 4. The shear bond strengths of Artglass and Targil to gold alloys were significantly decreased after thermocycling treatment(P<0.01). 5. Sculpture showed cohesive, adhesive, and mixed failure modes, but Artglass and Targis showed adhesive or mixed failures. And ceramic showed cohesive and mixed failures.

  • PDF