• 제목/요약/키워드: dental material

검색결과 1,376건 처리시간 0.031초

용융침투법으로 제조한 유리-알루미나 복합체: Ⅰ. 알루미나 입도 효과 (Glass-alumina Composites Prepared by Melt-infiltration: Ⅰ. Effect of Alumina Particle Size)

  • 이득용;장주웅;김대준;박일석;이준강;이명현;김배연
    • 한국세라믹학회지
    • /
    • 제38권9호
    • /
    • pp.799-805
    • /
    • 2001
  • 상용 알루미나 분말(0.5${\mu}$m, 3${\mu}$m)을 die-press법을 이용하여 1120$^{\circ}$C에서 2시간 1차 소결하여 다공성 전성형체를 제조하고 1100$^{\circ}$C에서 4시간 $La_2O_3-Al_2O_3-SiO_2$계 유리를 용융 침투시켜 치밀한 유리-알루미나 복합체를 제조하였다. 알루미나 입도가 유리-알루미나 복합체의 충진율, 미세조직, 젖음성, 기공률 및 크기, 기계적 특성에 미치는 영향을 조사하였다. 입도 범위가 0.1∼48${\mu}$m로 넓고 bimodal size 입도 분포를 가지면서 random orientation을 가진 3${\mu}$m 알루미나가 분산된 복합체가 최적의 기계적 특성 및 충진률이 관찰되었으며 강도와 인성값은 각각 519MPa, $4.5MPa{\cdot}m^{1/2}$이었다.

  • PDF

구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구 (A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS)

  • 강한중;동진근;오상천;이해형;송기창
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

$Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL)

  • 김우영;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

섬유강화형 복합레진브릿지의 파절강도 및 변연적합도에 관한 연구 (A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE)

  • 최호근;신상완;임호남;서규원
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.526-546
    • /
    • 2001
  • Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and the marginal fitness of fiber reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group. $Targis/Vectris^{(R)}$, $Sculpture-Fibrekor^{(R)}$, and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (${\times}50$). The results were as follows. : 1. The fracture strength according to the materials was significantly decreased in order In-Ceram($238.81{\pm}82$), Targis Vectris($176.25{\pm}18.93$), Sculpture-Fibrekor($120.35{\pm}20.08$) bridges. 2. FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3. The marginal accuracy was significantly decreased in order Targis/Vectris ($60.71{\mu}m$), Sculpture-Fibrekor($73.10{\mu}m$) In-ceram Bridge ($83.81{\mu}m$). 4. The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

성견 치주질환 이환 발치와에 즉시 임플란트 매식술시 Titanium plasma sprayed 임프란트와 Hydroxyapatite coated 임프란트의 계면조직에 관한 연구 (HISTOLOGICAL COMPARISONS OF TITANIUM PLASMA SPRAYED IMPLANT AND HYDROXYAPATITE COATED IMPLANT TO BONE INTERFACE IN PERIODONTALLY INVOLVED EXTRACTION SOCKETS IN DOGS)

  • 김진숙;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.400-410
    • /
    • 1993
  • Dental implants have been widely used in the treatment of esthetic and functional problems of the mouth due to alveolar bone loss, after tooth extraction. The success of implantation strongly depends on osseointegration. For osseointegration, implant material, methodology, and design have been investigated. For materials, two popular materials at present are titanium and hydroxyapatite. For methods, immediate implantation is being used recently. The purpose of this study is to evaluate osseointegration between the unthreaded cylindrical TPS implant and the HA-coated implant by a histomorphometric analysis. For this analysis, experimental periodontits was induced on the 3, 4 premolars of adult dogs by the ligation of orthodontic threads. Thereafter, each tooth was extracted. TPS. Implants and HA-coated implants were immediately inserted in the extraction socket. In control group, TPS implants were immediately inserted, and In experimental group, HA implants were immediately inserted. The dogs were sacrificed after 12 weeks, then the specimens were prepared for LM and histomorphometric analysis. The conclusion of this study is as follows l. In both control and experimental group, no inflammatory cells were observed. 2. The results of the histomorphometric analysis showed that the total osseointegration was 48.5% in control group, and 68.8% in expermental group. The experimental group was higher than the control group, and the difference was not statistically significant (p<0.05). 3. The results of the histomorphometric analysis showed that the osseointegration in the hole was 40.6% in control group, and 70.2% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). In both control and experinental group, no inflammatory cells were observed. 4. The results of the histomorphometric analysis showed that the osseointegration in the lower part was 52.1% in control group, and 73.3% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). 5. In experimental group, the bone to HA interface seemed to be mixed of bone and HA. We could not distinguish HA from the bone. The HA coating was detached from the titanium surface.

  • PDF

치과용 석고계 매몰재의 특성에 관한 연구 (STUDY ON THE PROPERTIES OF GYPSUM-BONDED DENTAL INVESTMENTS)

  • 김경선;우이형;최부병
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.139-165
    • /
    • 1991
  • The properties of a investment material can be described by the consistency at the slurry state, the setting time, the compressive strength and the thermal expansion during the casting. In this study the effect of the production parameters which are included the ratio of quartz and cristobalite, the content of binder, the water powder ratio and the content and concentration of additives on the properties of the gypsum-bonded investments has been investigated with help of the consistency test, the vicat needle test, the compressive strength test, the thermal expansion test, x-ray diffraction and DTA thermal differential test. The experimental results showed that the constitution of a investment with W/P ratio of 0.34, 30% of gypsum, 0.8% aluminium sulfate, 2% magnesium sulfate, 0.6% sodium phosphate was adapted for the properties of the KDA Spec. No. 13 type I investment. The important experimental results are summarized as follows. 1. The consistency of the investment decreased with increasing amount of aluminium sulfate and decreasing amount of sodium phosphate. An addition of magnesium sulfate up to 2% an increase of the consistency was shown. But 3% magnesium sulfate in investment showed a decrease of consistency. The consistency did not vary significantly with a variation of the content of gypsum and cristobalite and the W/P ratio. 2. Aluminium sulfata and the magnesium sulfate promoted the hardening and the aluminium phoshpate delayed the hardening. The setting time increased with amount of gypsum. The effect of the matrix on the setting time was insignificant. With the W/P ratio of 0.34 the setting time was 14 min. 3. The compressive strength decreased with the amount of aluminium sulfate up to 0.25% and increased with the amount of aluminium sulfate greater than 3%. The compressive strength decreased as decreasing the amount of magnesium sulfate and gypsum and as increasing the W/P ratio. The effect fo the refractory on the compressive strength was also not significant. With the W/P ratio of 0.34 the compressive strength was $34Kg/mm^2$. 4. The 1st thermal expansion was found at the temperature near $250^{\circ}C$ and the steady state or the contraction stage was found at the temperature between $250^{\circ}C$ and $500^{\circ}C$. After this stage the 2nd thermal expansion took place at the temperature near $500^{\circ}C$. The amount of thermal expansion increased with decreasing the content of magnesium sulfate, aluminium sulfate and gypsum and the W/P ratio. And the amount of thermal expansion increased as the content of sodium phosphate ad cristobalite. With the W/P ratio of 0.34 the amount of total expansion was 1.2%.

  • PDF

유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석 (Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis)

  • 김경탁;조광헌;이청희;유원재;이규복
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.385-393
    • /
    • 2009
  • 연구목적: 임플란트 경부 디자인의 차이가 경부 치밀골의 응력분포에 미치는 영향을 유한요소법을 이용하여 분석하고자 한다. 연구재료 및 방법: 몸체 형상은 유사 (직경 4.3 mm, 길이 10 mm)하나 경부 디자인이 internal형, external형, 및 submerged형으로 다른 3종의 임플란트 시스템 ((주)덴티스, 대구, 대한민국)에 대하여 축대칭 유한요소모델을 사용하여 해석하였다. 악골 폭경은 7 mm로 동일하게 모델링하였고 하중 조건으로는 임플란트 장축에 평행한 수직하중 50 N, 임플란트 장축에 $45^{\circ}$방향으로 작용하는 경사력 50N을 설정하였다. 결과: 해석한 3종의 임플란트 모두 경부 피질골에 응력집중을 발생시켰으며 디자인 차이에 따른 응력 수준의 차이가 관찰되었다. 경부 피질골의 최대 응력은 수직력 조건에서 internal형, submerged형, external형의 순으로 컸으며, 그 값은 각각 2.71, 2.60, 2.48 MPa였다. 경사력 조건에서는 internal형, external형, submerged형의 순으로 컸으며 그 값은 각각 9.30, 9.14, 8.97 MPa였다. 결론: 임플란트 경부 디자인이 주위 치밀골의 응력 분포에 영향을 미칠 수 있지만 그 차이는 크지 않은 것으로 분석되었다.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

키토산의 치주조직 재생력에 대한 연구의 고찰: 조직계측학적 메타분석 (Study of chitosan's effects on periodontal tissue regeneration: a meta-analysis of the histomorphometry)

  • 양진혁;채경준;윤정호;정의원;이용근;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제38권1호
    • /
    • pp.7-14
    • /
    • 2008
  • Purpose: Chitosan & chitosan derivative(eg. membrane) have been studied in periodontal regeneration, and recently many studies of chitosan have reported good results. If chitosan's effects on periodontal regeneration are enhanced, we can use chitosan in many clinical and experimental fields. For this purpose, this study reviewed available literatures, evaluated comparable experimental models. Materials and Methods: Ten in vivo studies reporting chitosan's effects on periodontal tissue regeneration have been selected by use of the 'Pubmed' and hand searching. Results: 1. In Sprague Dawley rat calvarial defect models, amount of newly formed bone in defects showed significant differences between chitosan/chitosan-carrier/chitosan-membrane groups and control groups. 2. In beagle canine 1-wall intrabony defect models, amount of new cementum and new bone showed significant differences between chitosan/chitosan-membrane groups and control groups. The mean values of the above experimental groups were greater than the control groups. Conclusion: The results of this study have demonstrated that periodontal regeneration procedure using chitosan have beneficial effects, which will be substitute for various periodontal regenerative treatment area. One step forward in manufacturing process of chitosan membrane and in use in combination with other effective materials(eg. bone graft material or carrier) may bring us many chances of common use of chitosan in various periodontal area.