• Title/Summary/Keyword: dental Lab.

Search Result 305, Processing Time 0.023 seconds

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Comparison of the accuracy of digital models made from white light scanner by scanning method (스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Jae-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Comparative analysis on digital models obtained by white light and blue LED optical scanners (백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석)

  • Choi, Seog-Soon;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

Evaluation of flexural properties and reliability with photo-curing 3D printing resin according to the printing orientations (광경화성 3D 프린팅 레진의 출력각도에 따른 굽힘 특성과 신뢰성 평가)

  • Im, Yong-Woon;Song, Doo-Bin;Hwang, Seong-Sig;Kim, Sa-Hak;Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.43 no.1
    • /
    • pp.13-18
    • /
    • 2021
  • Purpose: This study aimed to compare the flexural properties and perform the Weibull analysis of photo-curing three-dimensional (3D) printing resin. Methods: Photo-curing temporary resin (3D polymer) was used as a printing resin. Specimens (65 × 10 × 3.3 ㎣) were prepared following the ISO 20975-1 guidelines and according to the different printing orientations using a digital light processing 3D printer (D2 120; Dentium). The flexural strength (FS), flexural modulus, and work of fracture (WOF) were measured using a universal testing machine (Instron 3344; Instron) at a crosshead speed of 5 mm/min. Results: In this study, the 0° orientation exhibited higher FS and WOF than the 45° orientation. Significant differences were found among the printing orientations (p<0.05). Specimens printed at the 0° orientation were the most accurate. In the Weibull analysis, 0° showed the greatest Weibull modulus (m), which represents a higher reliability. Conclusion: 3D printing should be selected and used by considering flexural properties, size accuracy, and reliability.

Piezo-assisted Intracytoplasmic Sperm Injection in Cattle

  • Kim, Se-Woong;Kang, Ho-In;Sung, Ji-Hye;Roh, Sang-Ho
    • Journal of Embryo Transfer
    • /
    • v.25 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • Intracytoplasmic sperm injection (ICSI) is one of the artificial fertilization methods when only a few sperm are available for insemination, and an important tool for the preservation of genetic materials of endangered animal species, especially the male is infertile. Different from other species such as mice and pigs, the conventional ICSI method which uses spiked pipette for injection (Spike-ICSI) is exhibited low success rates in cattle because the bovinesperm head membrane is hard to break during injection procedure. We chose piezo-assisted ICSI (Piezo-ICSI) for the improvement of the injection procedure including sperm head membrane rupture and efficient puncture of the plasma membrane of the oocytes. In this experiment, we compared the efficacy of the bovine ICSI embryo production between the Piezo-ICSI and Spike-ICSI. The second polar body extrusion, pronuclear formation, cleavage and blastocyst formation were evaluated after implementation of two different ICSI techniques. The Piezo-ICSI tended to show comparably higher rates of the second polar body extrusion (41.7%), the pronuclei formation (42.9%) and the two-cell cleavage (41.4%) than Spike-ICSI does (33.3%, 28.6% and 23.5%, respectively) although there is no statistic significance between two groups. In addition, the blastocysts were only obtained from the Piezo-ICSI group (10.3%). Our finding shows that the Piezo-ICSI may be used as an artificial fertilization method in cattle when in vitro fertilization is not applicable.

Suggestions on the implementation plan for job-based dental technician practical exam (직무기반 치과기공사 실기시험 시행 방안에 대한 제언)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.181-185
    • /
    • 2021
  • Purpose: This study aims to make suggestions for the implementation of the job-based dental technician practical exam. Methods: The duties of dental technicians and the recent trends in the dental technician field were defined and identified, respectively, to achieve the purpose of the current study. The practical test system of domestic and foreign national tests was comparatively analyzed to seek improvements. Additionally, the direction of the practical test to be taken in the future was investigated through a public hearing of domestic experts. Results: As a result of this study, the job site of dental technicians was recently found to be undergoing many changes, and it can be observed that related laws and the work site have already changed. Comparison of overseas test systems showed that Korea was limited to a rather small evaluation range; in general, the scope of the evaluation of the practical tests in foreign countries was widely conducted. In the results of the public hearing, opinions exist that the evaluation range of the practical test was expanded and that new subjects were needed, but the opinion on the existence of practical difficulties was mainly mentioned. Conclusion: The evaluation range of the current practical examination subjects should be expanded and the evaluation of digital dental engineering subjects should be added to proceed with the job-based practical examination. However, it seems that efforts should be made gradually through various efforts in the future due to practical difficulties.

Stemness and Proliferation of Murine Skin-Derived Precursor Cells under Hypoxic Environment

  • Kim, Hyewon;Park, Sangkyu;Roh, Sangho
    • International Journal of Oral Biology
    • /
    • v.41 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Skin-derived precursors (SKPs) have potential to differentiate to various cell types including osteoblasts, adipocytes and neurons. SKPs are a candidate for cell-based therapy since they are easily accessible and have multipotency. Most mammalian cells are exposed to a low oxygen environment with 1 to 5% $O_2$ concentration in vivo, while 21% $O_2$ concentration is common in in vitro culture. The difference between in vitro and in vivo $O_2$ concentration may affect to the behavior of cultured cells. In this report, we investigated the effect of hypoxic condition on stemness and proliferation of SKPs. The results indicated that SKPs exposed to hypoxic condition for 5 days showed no change in proliferation. In terms of mRNA expression, hypoxia maintained expression of stemness markers; whereas, oncogenes, such as Klf4 and c-Myc, were downregulated, and the expression of Nestin, related to cancer migration, was also downregulated. Thus, SKPs cultured in hypoxia may reduce the risk of cancer in SKP cell-based therapy.

Influences of Sprue joint Forms on Castability in dental Restorations (치과보철물 제작시 Sprue 부착 형태가 주조성에 미치는 영향)

  • Choi, Un-Jea;So, Jung-Mo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.151-160
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of sprue joint form on castability in dental prosthetics. The researcher carried out experimental study according to the type was divided by sprue joint form. Therefore type A was made thicken than sprue diameter of type B and type C was made it conversely. The results were as follows: 1. In the order of castability, type C(87.8%) was first and then type A(87.0%) and type B(79.2%) was last. However there was no significant difference statistically. 2. If reservior was located at the correct position and in sufficient size, internal shrinkage porosity in the casting bodies were not generated in the type of all. 3. At the reservoir, internal shrinkage porosity was generated first in type A, followed by type Band type C in the order named. Although it gives no impact on casting body, porosity seems to appear the least when it's produced in the form of type C.

  • PDF