• Title/Summary/Keyword: density index

Search Result 1,932, Processing Time 0.028 seconds

Polydispersity and Particle Size Distribution of Polystyrene Latex Prepared by Ultrasound Induced Emulsion Polymerization (초음파에너지가 도입된 유화중합공정에서 Polystyrene Latex의 분산도 및 입자분포 특성)

  • Kim, Won-Il;Hong, In-Kwon
    • Elastomers and Composites
    • /
    • v.33 no.2
    • /
    • pp.110-116
    • /
    • 1998
  • A new technology was introduced to the emulsion polymerization. It is the ultrasonic activation method which replaced a chemical initiator and the environmentally benign process. In this study, free radicals were produced by a pulse type ultrasound energy irradiation, then polystyrene latex was polymerized without chemical initiator. With ultrasonic energy density, the degree of polymerization, average molecular weight, and particle size were increased, but the polydispersity index for the molecular weight and the particle size were decreased. The optimum condition of emulsifier concentration and temperature was found to be 1.0 wt.% SDS and $40^{\circ}C$, respectively. As a result, the emulsion polymerization process without chemical initiator was proved to be comparable to common latex properties such as average molecular weight, molecular weight distribution, particle size, etc.

  • PDF

Design and Simulation of an 808 nm InAlAs/AlGaAs GRIN-SCH Quantum Dot Laser Diode

  • Chan, Trevor;Son, Sung-Hun;Kim, Kyoung-Chan;Kim, Tae-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.124-127
    • /
    • 2011
  • Quantum dots were designed within a GRIN-SCH(Graded index - Separate confinement Heterostructure) heterostructure to create a high power InAlAs/AlGaAs laser diode. 808 nm light emission was with a quantum dot composition of In0.665Al0.335As and wetting layer composition of Al0.2Ga0.8As by LASTIP simulation software. Typical characteristics of GRIN structures such as high confinement ratios and Gaussian beam profiles were shown to still apply when quantum dots are used as the active media. With a dot density of 1.0x1011 dots/cm2, two quantum dot layers were found to be good enough for low threshold, high-power laser applications.

Recent Advances in Dry-bag CIP Equipment

  • Kishi, Yoshikazu;Miyashita, Yasuhide;Manabe, Yasuo;Fujikawa, Takao
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1259-1260
    • /
    • 2006
  • Intensive technological research on the Dry-bag CIP equipment was carried out to improve the dimensional accuracy and the productivity. The rubber mold design technology using FEM simulation during pressing was introduced, in order to achieve higher dimensional preciseness, and criteria for the selection of the In-line type or Off-line type, were established based on the powder flowability index proposed by Carr. Based on these research results, high productivity Off-line Dry-bag CIP equipment, which can realize good dimensional accuracy with high productivity, was developed even for non-granulated powders with poor packing density.

  • PDF

Fuzzy Clustering using Evolution Program (진화 프로그램을 이용한 퍼지 클러스터링)

  • 정창호;임영희;박주영;박대희
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.1
    • /
    • pp.130-130
    • /
    • 1999
  • In this paper, we propose a novel design method for improving performance of existing FCM-type clustering algorithms. First, we define the performance measure which focuses on bothcompactness and separation of clusters. Next, we optimize this measure using evolution program.Especially the proposed method has following merits: ① using evolution program, it solves suchproblems as initialization, number of clusters, and convergence to local optimum ② it reduces searchspace and improves convergence speed of algorithm since it represents chromosome with possiblepotential centers which are selected possible candidates of centers by density measure ③ it improvesperformance of clustering algorithm with the performance index which embedded both compactnessand separation Properties ④ it is robust to noise data since it minimizes its effect on center search.

Optical Characterization of DBR Porous Silicon by Changing of Applied Current Density (전류세기의 변화에 따른 DBR 다공성 실리콘의 광학적 특성)

  • Choi, Tae-Eun;Park, Jaehyun
    • Journal of Integrative Natural Science
    • /
    • v.2 no.2
    • /
    • pp.82-85
    • /
    • 2009
  • Distributed Bragg reflector (DBR) porous silicon (PSi) was generated by an electrochemical etching a bragg structure into a silicon wafer through electrode current in aqueous ethanolic HF solution. DBR PSi exhibiting unique reflectivity was successfully obtained by an electrochemical etching of silicon wafer using square current waveform. The multilayered photonic crystals of DBR PSi exhibited the reflection of a specific wavelength with high reflectivity in the optical reflectivity spectrum. In this work, we have developed a method to create refractive index in Si substrate through intensity of an electric current. The electrochemical process allows for precise control of the structural properties of DBR PSi such as thickness of the porous layer, porosity, and average pore diameter. The number of reflection peak of DBR PSi and its pore size increased as the intensity of electric current increased. This might be a demonstration for the fabrication of specific reflectors or filters.

  • PDF

Exploration of a New Method of Spatial Analysis to Predict the Pedestrian Pattern in the Circulation Spaces of Shopping Centers: The Case of Shenzhen

  • Bai, Xue;Yao, Shen
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.171-183
    • /
    • 2018
  • Turner and Penn (1) from UCL have proved that Visibility Graph Analysis (VGA) can be used as a more accurate method to predict the pedestrian distribution in building spaces. However, this methodology neglects certain elements that are of special influence on pedestrian distribution in buildings, especially the entrances and exits. Based on Space Syntax, this dissertation improves on the traditional method of Visibility Graph Analysis, using three shopping centers in Shenzhen as examples, attempts to explore a new parameter - "attenuation index of pedestrians at the entrances and exits" - using relevant data of the entrances and exits of the three cases, and combines it with traditional VGA analysis through weighted calculation, in order to provide more accurate predictions of pedestrian patterns in shopping centers.

Fire safety evaluation of the subway car's interior materials (지하철 내장재료의 재료특성에 따른 화재안전도 평가)

  • Lee Duck-Hee;Jung Woo-Sung;Lee Cheul-Kyu;Kim Sun-Ok
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.327-332
    • /
    • 2003
  • We investigated the fire characteristics of the subway electric car's interior materials and evaluated the safety of it. The testing methods are ISO 4589-2 for Limited Oxygen Index, ISO 5658-2 for surface flame spread, ISO 5660-1 for Heat Release Rate, ASTM E 662 for smoke density and BS 6852 Annex B.2 for gas toxicity. The materials of seven organization including KNR were tested. Most of the materials are under the levels of the foreign country's demand. We also reported the test methods of other countries and compared it to ours.

  • PDF

A Study on Correlations between Compaction Properties and Soil Constants of Granite Soil in the Kangwon Province (강원도에 분포하는 화강토의 다짐특성 및 토질정수의 상관관계에 관한 연구)

  • Yoo, Nam-Jae;Park, Byung-Soo;Hong, Young-Gil
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.77-86
    • /
    • 1998
  • This study is to provide the useful data for the design and construction of the geotechnical engineering works by collecting and analyzing the soil properties of granite soil in the Kangwon Province. Data base was obtained from 92 field sites in the Kangwon province divided into 15 areas based on administration district. Total numbers of data were 478. Correlations between soil constants, especially compaction properties, were obtained by performing statistical analysis. Analyzed results were as follows. 1. Most of granite soil consists of SM and GM based on United Soil Classification System. 2. Mean gravity of granite soil is 2.65 3. High correlations between optimum moisture content and the maximum dry density, plasticity index and liquid limit are obtained. 4. Analyzed results between other soil constants show relatively low correlation. However, they show consistent trends matchable to geotechnical engineering senses.

  • PDF

$CaF_2$ crystal growth for using optical components of laser

  • Seo, Soo-Hyung;Kyoung Joo;Auh, Keun-Ho
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.09a
    • /
    • pp.9-13
    • /
    • 1998
  • Large vacuum Bridgman-Stockbarger (BS) equipments was composed for growing large diameter CaF2 crystals. The CaF2 crystal of 4.5-inch was grown under the conditions of freezing temperature gradient of 12$^{\circ}C$/cm and growing rate of 3mm/hr. Also the 6-inch crystal was grown by using thermal stabilization method under freezing temperature gradient of 14$^{\circ}C$/cm and growing rate of 2mm/hr. The dislocation density was characterized for evaluating the quality of crystals. And the optical properties such as transmittance, refractive index and fluorescence were analyzed in order to investigate on the applications of optical components.

  • PDF

Study on Improvement of Blood Stagnation by Pulsed Magnetic Field

  • Son, Hee Jung;Yoo, Jun Sang;Lee, Myeung Hee;Hwang, Do Gwen;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.114-119
    • /
    • 2015
  • This study explored the effect of pulsed magnetic field (PMF) stimulus on the improvement of blood stagnation by means of photoplethysmography (PPG). Our stimulus system was designed to generate PMF with a maximum intensity variation of 0.20 T at a transition time of $160{\mu}s$, with pulse intervals of 1 Hz. In order to quantitatively estimate vascular condition, indices such as blood vessel tension (BVT), stress power (SP), differential pulse wave index (DPI) and remained blood volume (RBV) were calculated from the second derivative of the PPG signal and power density spectrum (PDS). Our results showed that non-invasive PMF stimulus was effective in improving blood stagnation. Therefore, it may be concluded that appropriate PMF stimulus affects the blood circulatory system.