• Title/Summary/Keyword: defect rate

Search Result 895, Processing Time 0.029 seconds

A Study on the Characteristics of Electro Polishing and Utility Materials for Transit High Purity Gas (청정도 가스 이송용 재료의 특성과 전해연마에 관한 연구)

  • Lee, Jong-Hyung;Park, Shin-Kyu;Yang, Seong-Hyeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.3
    • /
    • pp.259-263
    • /
    • 2004
  • In the manufacture progress of LCD or semiconductor, there are used many kinds of gas like erosion gas, dilution gas, toxic gas as a progress which used these gas there are required high puritize to increase accumulation rate of semiconductor or LCD materials work progress of semiconductor or LCD it demand many things like the material which could minimize metallic dust that could be occured by reaction between gas and transfer pipe laying material, illumination of the surface, emition of the gas, metal liquation, welding etc also demand quality geting stricted. Material-Low-sulfur-contend (0.007-0010), vacuum-arc-remelt(VAR), seamless, high-purity tubing material is recommend for enhance welding lower surface defect density All wetted stainless steel surface must be 316LSS elecrto polishinged with ${\leq}0.254{\mu}m$($10.0{\mu}in$) Ra average surface finish, $Cr/Fe{\geq}1.1$ and $Cr_2O_3$ thickness ${\geq}25{\AA}$ From the AES analytical the oxide layer thickness (23.5~36 angstroms silicon dioxide equivalent) and chromum to iron ratios is similar to those generally found on electropolished stainless steel., molybdenum and silicon contaminants ; elements characteristic of stainless steel (iron, nickel and chromium); and oxygen were found on the surface Phosphorus and nitrogen are common contaminants from the electropolish and passivation steps.

  • PDF

Bone Healing in Ovariectomized-rabbit Calvarial Defect with Tricalcium Phosphate Coated with Recombinant Human Bone Morphogenetic Protein-2 Genetically Engineered in Escherichia coli

  • Kim, Jung-Han;Kim, Chang-Joo;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.2
    • /
    • pp.37-49
    • /
    • 2014
  • Purpose: This study compares the bone formation ability of tricalcium phosphate (TCP) with and without recombinant human bone morphogenetic protein-2 (rhBMP-2) and assesses TCP as a carrier of rhBMP-2. Methods: Bilateral round defects (diameter: 8.0 mm) were formed in the cranium of eight New Zealand white rabbits. The defects were grafted with TCP only (control group) or with rhBMP-2-coated TCP (experimental group). The animals were sacrificed at 1st week, 2nd week, 4th week, and 8th week postoperatively; two rabbits sacrificed each time. The skulls were harvested and subjected to radiographic and histological examination. Results: Radiologic evaluation showed faster bone remodeling in the experimental group than in the control group. Histologic evaluation (H&E, Masson's trichrome stain) showed rapid bone formation, remodeling and calcification in the 1st and 2nd week in the experimental group. Immunohistochemical evaluation showed higher expression rate of osteoprotegerin, receptor activator of nuclear factor ${\kappa}B$ ligand, and receptor activator of nuclear factor ${\kappa}B$ in the experimental group at the 1st and 2nd week than in the control group. Conclusion: rhBMP-2 coated TCP resulted in rapid bone formation, remodeling, and calcification due to rhBMP-2's osteogenic effect. TCP performed properly as a carrier for rhBMP-2. Thus, the use of an rhBMP-2 coating on TCP had a synergic effect on bone healing and, especially, bone remodeling and maturation.

Growth of ${\gamma}-6Bi_2O_3 {\cdot}SiO_2$( Single Crystals by EFG Method (EFG법에 의한 ${\gamma}-6Bi_2O_3 {\cdot}SiO_2$(BSO)단결정의 육성)

  • ;;Kei-Miyamto
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.1
    • /
    • pp.26-38
    • /
    • 1991
  • The fundamental conditions for growing $r-6Bi_2O_3{\cdot}SiO_2$(BSO) single crystal plates by EFG(Edge-defined Film-fed Growth) method, were investigated and characterization, quality test, property measurement were performed for obtained BSO single crystal plates. The opti$\mu$ growing conditions determined in this study were as follows: ${\cdot}$temperature gradient;$24^{\circ}C/cm$ ${\cdot}$pulling rate;2.0mm/h. BSO Single crystal plates grown at the above optimum conditions did not include secondary phase or grain boundary and were confirmed as single crystals by X-ray analysis. IT was found that the single crystal plates had <100> growth direction. G defects, ie pore, void inclusion, striation, were not detected in the single crystal plate under polarizing microscope but dislocations(microscopic defect) were found and dislocation density was $5.1\times10^5/cm^2$.

  • PDF

A Study on Improvement of Liquid Aluminum sulfate Manufacturing Process Using Automation Measurement System (자동화 계측 시스템 설계를 통한 액상황산알루미늄 제조 공정의 개선에 관한 연구)

  • Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.5
    • /
    • pp.31-37
    • /
    • 2017
  • In this Paper, we have Improved the Manufacturing Process of Liquid Aluminum Sulfate using the Design of Automated Measurement Systems. The Manufacturing Process of Liquid Aluminum Sulfate uses a Large Weight. The Quality of a Product Depends Highly on the Proportion of the Raw Material Input in the Production Process. Therefore, it is Very Important to Accurately Measure the Amount of Raw Material. For Automation Design, Load Cell Sensor which can Measure Large Weight Accurately and PLC Technology which is most used in Automation Process are Applied. The Content of Aluminum Oxide in the Aluminum Sulfate Produced before the Automation Design Varies from 8.023% to 8.250%. However, after Automation Design, the Amount of Change from 8.09% to 8.19% was Greatly Reduced. As a Result, we could Reduce the Quality Defect rate Due to Weighing Errors and Reduce Safety Accidents by Applying Automation System.

Analysis of PD Distribution Characteristics and Comparison of Classification Methods according to Electrical Tree Source in Power Cable (전력용 케이블 시편에서 전기트리 발생원에 따른 부분방전 분포 특성 및 발생원 분류기법 비교)

  • Park, Seong-Hee;Jeong, Hae-Eun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • One of the cause of insulation failure in power cable is well known by electrical treeing discharge. This is occurred for imposed continuous stress at cable. And this event is related to safety, reliability and maintenance. In this paper, throughout analysis of partial discharge(PD) distribution when occurring the electrical tree, is studied for the purpose of knowing of electrical treeing discharge characteristics according to defects. Own characteristic of tree will be differently processed in each defect and this reason is the first purpose of this paper. To acquire PD data, three defective tree models were made. And their own data is shown by the phase-resolved partial discharge method (PRPD). As a result of PRPD, tree discharge sources have their own characteristics. And if other defects (void, metal particle) exist internal power cable then their characteristics are shown very different. This result Is related to the time of breakdown and this is importance of cable diagnosis. And classification method of PD sources was studied in this paper. It needs select the most useful method to apply PD data classification one of the proposed method. To meet the requirement, we select methods of different type. That is, neural network(NN-BP), adaptive neuro-fuzzy inference system and PCA-LDA were applied to result. As a result of, ANFIS shows the highest rate which value is 98 %. Generally, PCA-LDA and ANFIS are better than BP. Finally, we performed classification of tree progress using ANFIS and that result is 92 %.

Domestic and Foreign literature review of Dental Accidents and Malpractice claims (치과의료사고 및 분쟁에 대한 국내·외 문헌고찰)

  • Kim, Myeng Ki;Cho, Han A;Lee, Jin-han
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.82-95
    • /
    • 2015
  • Background: Interest in medical malpractice claims and accidents is a day-to-day social issue to general public as well as medical personnel. Related laws and regulations already have been established, and institutions based on the laws and regulations also have been founded. However, in our dental community, interest and response to the issue seem insufficient. Methods: We searched four medical literature databases that are mainly cited in the medical community. Keywords including 'dental malpractice claims', 'patient safety' and 'medical accident' were used for the search. Among the selected literatures, we chose specific ones separately whose content is authentic and easily approachable. Results: Medical malpractice claims and accidents tend to increase around the world. As the cost or the difficulty level of surgery increases, the dispute rate also increases, which appears even more apparent in developed countries. Preventive measures to prevent the disputes and accidents are not significantly different. Three critical of them include relationship of doctor with patient, the informed consent and medical record. Conclusion: Tools for accident occurrence or communication improvement have been introduced. All of those cost time and money. However, education or professional request of liability insurance companies, self-education and provision of guidelines can be immediately implemented. To implement those, dentists' promotion at the regional or national level is imperative. rhBMP-2 is widely used at sinus augmentation, alveolar bone defect, and socket preservation.

Use of the Tenocutaneous Free Flap In Hand Reconstruction (유리 건 피판을 이용한 수부 재건술)

  • Chung, Duke-Whan;Han, Chung-Soo;Kim, Ki-Bong;Yi, Jin-Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.93-98
    • /
    • 2001
  • Purpose : This describes our experience with a tenocutaneous free flap from the dorsum of the foot or radial forearm to reconstruct the dorsal skin and extensor tendons of the hand. Material and Methods : Between february 1987 and July 1998, we treated 9 patients with composite tissue loss on the dorsal hand caused by crushing injury. Nine men had an average age of 26.4 years(range, $19{\sim}47$). We treated 5 patients with the free dorsalis pedis flap including the extensor tendons and the superficial peroneal nerve and 4 patients with reverse forearm flap including the brachioradialis tendon and/or superficial radial nerve. Flap size was average 4.4(3,2cm. Evaluation of the results was based on the survived flap rate, the recovery rates for range of motion of the metacarpophalageal joints in the operated fingers. two-point discrimination. Results : All flaps were well vascularized and survived completely. Recovery rates for range of motion of the metacarpophalageal joints in operated fingers range from $78%{\sim}99%$(average, 90%). Two-point discrimination of the transferred flaps in 5 patients average $20{\pm}3.5mm$. Conclusion : The advantages of this procedure are mass action reconstruction with tendon, one-stage operation, faster healing with less adhesion formation, and early mobilization.

  • PDF

Developing die and Peripheral Equipment Used for the Manufacture of Octagonal Outlet Boxes (8각 아웃렛 박스 제조용 금형 및 주변기기 개발)

  • Chio Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.560-565
    • /
    • 2005
  • This paper deals with the development of manually operated die used for the manufacture of octagonal boxes into two sets of automated die. In particular, theoctagonal boxes are used fur the switch boxes intended fur the cable conduit of buildings or f3r wiring connection. Manufacturing these boxes requires forming the materials using the primary press before they undergo 2nd through 6th processing by the press machine including the four sides of the octagonal outlet box and bending. Such complicated process hikes up labor cost, slows down production, and results in defect rate of $10\%$ or higher; hence the overall rise in manufacturing cost. Moreover, workers avoid this type of work due to the roar and vibration coming from the press and the risk of accident. To eliminate such phenomenon, a CAM die made by integrating five sets of die into one set of die and an automatic conveyor system were developed. As a result, unmanned work was realized with only two units of press and two sets of die; thus solving the problem of work being avoided and saving on manufacturing cost.

  • PDF

Comparison of map display styles of vehicle navigation system on human factors (차량 항법장치의 화면표시형태에 대한 인간공학적 비교)

  • Jung, Beom-Jin;Baek, Seung-Ryul;Kim, Gi-Beom;Park, Beom
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.208-213
    • /
    • 1995
  • The vehicle navigation system is developed for helping driver to retrieve driving information more easily and lastly. Navigation System informs driver many pieces of driving information - roadway structure and system, on-line traffic condition, the position of vehicle, route guidance, destination and other infor- mation service. As the style of information is diverse and the amount of information is large, driver may have mental and visual overload. The display of information can disturb the driver's attention and this can cause accidents. This state is caused by the defect of human-machine interactions. When the navigation system is designed, human factors - cognitive, judgment, operating -must be considered. The display style must be designed simply and easily, not to be obstacle of human - machine interface. In this study, outside- in view display style and inside-out view display style are compared each other. Tow factors are measured. One is cognitive factor-time of cognition on information that is displayed by screen display, cognition error rate. The other is image of screen display - subject's feeling about several styles of display, degree of subject's preference. The prototype of roadway is four kinds -Cross, T-cross and O-cross. Roadway display for test is taken from paper maps. Traffic condition display style, vehicle position display style and route guidance display style are taken from current display style. Traffic condition display style is symbol. vehicle position display style and route guidance display style are described as color and symbol. The test on screen display is implemented doing given tasks. Then the test is analyzed statistically. The result of test analysis gives the guideline to the designer for the map display of the vehicle navigation system.

  • PDF

Complete A-V Block 3 Months after Total Correction of Tetralogy of Fallot (활로 4징증의 근치수술후의 원격 방실전도 차단)

  • 송요준
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.326-332
    • /
    • 1978
  • There appears some conduction defects frequently after total correction of Tetralogy of Fallot. Common defect is right bundle branch block due to surgical intervention. We experienced complete A-V block which occured 3 months later after total correction of Tetralogy of Fallot in a 8 year old boy. The patient was completely free of any A-V block after the operation for 3 months, and sudden onset of A-V block with coupled premature ventricular contractions resulted him in shock state during the attack of severe bronchopneumonia for 4 days prior to the second visit. Emergency implantation of Cordis demand type temporary pacemaker was necessary to control the complete heart block with bradyarrhythmia and frequent ventricular fibrillation. Permanent cardiac pacemaker was implanted two weeks later as indicated with Cordis Stanicor lambda demand pacemaker, and the patient was discharged uneventfully on the 8th post implantation day with the heart rate of 72/min. Another 3 months after the implantation, the patient was transported to this hospital as dead on arrival after an accidental fall from a 2 meter height, and all possible cardiopulmonary resuscitation was performed for 60 minutes at the emergency room in vain. Autopsy was done to find out the cause of sudden death and the etiology of complete heart block. Microscopic focal infarctions with scar formation were noted along the course of conduction system in the interventricular septum, which might be the main cause of complete heart block during the attack of severe bronchopneumonia complicated with acute bacterial endocarditis. The tip of the pacemaker wire was slipped from the granulation scar at the apex of the right ventricular cavity, and this might be the direct cause of pacing failure and death.

  • PDF