• Title/Summary/Keyword: defect morphology

Search Result 113, Processing Time 0.025 seconds

A study on the etch pits morphology and the defect in as-grown SiC single crystals (SiC 단결정의 etch pit 형상과 결함에 관한 고찰)

  • 강승민
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.6
    • /
    • pp.373-377
    • /
    • 2000
  • For 6H-SiC single crystals which was obtained by sublimation growth (modified Lely process), the relation between the defects and the etch pits to be formed at the site of dislocations were discussed. Typical hexagonal etch pits were formed on (0001) basal plane. The similar hexagonal etch pit shapes were formed on the site of micropipe defects and it was realized that internal planar defects was formed with the same matrix crystal structure as grown crystals, through the observation of the etching morphology at those internal defects.

  • PDF

Simplified nonsurgical treatment of peri-implantitis using chlorhexidine and minocycline hydrochloride

  • Heo, SunJin;Kim, Hyun-Joo;Joo, Ji-Young;Lee, Juyoun;Kim, Sung-Jo;Choi, Jeomil
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.5
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: The present study investigated the outcomes of a newly-developed, simple, and practical nonsurgical treatment modality suitable for most forms of intrabony defects around failing dental implants using intrasulcular delivery of chlorhexidine solution and minocycline hydrochloride (HCl). Methods: Forty-five dental implants in 20 patients diagnosed with peri-implantitis were included. At baseline and the study endpoint, the probing pocket depth (PPD), clinical attachment level (CAL), and the presence of bleeding on probing (BOP) at 6 sites around each implant were recorded. The radiographic osseous defect morphology at the mesial or distal proximal aspect of each implant was classified as 1) narrow or wide and 2) shallow or deep. For a comparative analysis of bone changes according to the defect morphology, the distance from the implant shoulder to the most coronal bone-to-implant contact point (DIB) at the mesial and distal aspects of each implant was measured at baseline and the endpoint. Patients were scheduled to visit the clinic every 2-4 weeks for intrasulcular irrigation of chlorhexidine and delivery of minocycline HCl. Results: We observed statistically significant decreases in PPD, CAL, and BOP after treatment. At the endpoint, bone levels increased in all defects, regardless of the osseous morphology of the intrabony defect. The mean DIB change in deep defects was significantly greater than that in shallow defects. Although the mean bone gain in narrow defects was greater than in wide defects, the difference was not statistically significant. Conclusions: We propose that significant and sustainable improvements in both clinical and radiographic parameters can be expected when intrabony defects around dental implants are managed through a simple nonsurgical approach involving combined intrasulcular chlorhexidine irrigation and local delivery of minocycline HCl.

Investigation of Streaky Mark Defect on Hot Dip Galvannealed IF Steel

  • Xinyan, Jin;Li, Wang;Xin, Liu
    • Corrosion Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.109-115
    • /
    • 2010
  • Interstitial-free (IF) steels are widely used for car body material. However, a few types of streaky mark defect are commonly found on hot dip galvannealed (GA) IF steel sheets. In the present study, both the phase structure of a streaky mark defect and the microstructure of the substrate just below it were characterized by optical microscopy (OM) and scanning electron microscopy (SEM). It was found that the bright streaky mark area was composed of ${\delta}$ phase while the dark normal area was full of craters. More than half of the grains at the uppermost surface of the substrate just below the streaky mark defect are unrecrystallized grains which could result from lower finish rolling temperature during hot rolling and be kept stable during the annealing process, while almost all the grains in the normal area are equiaxed grains. In order to confirm the effect of the unrecrystallized grains on the coating morphology, hot dip galvannealing simulation experiments were carried out in IWATANI HDPS. It is proved that the unrecrystallized grains accelerate the Fe-Zn reaction rate during galvannealing and result in a flatter coating surface and an even coating thickness. Finally, a formation mechanism of the streaky mark defect on the hot dip galvannealed IF steel sheet was discussed.

On the TFT-LCD Cell Defect Inspection Algorithm using Morphology (모폴로지(Morphology)를 이용한 TFT-LCD 셀 검사 알고리즘 연구)

  • Kim, Yong-Kwan;Yu, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • In this paper, we develope and implement a TFT-LCD cell defects detection algorithm using morphology. To detect the bright line or dark line defects and the bright pixel or dark pixel defects of the TFT-LCD cells, we determine the shape of the morphology operators considering the shape characteristics of the TFT-LCD sub pixels. Using dilation, erosion, and the subtraction operators, we extract gray level defects information. Then, we apply the optimal threshold method which shows the best results in terms of several criteria. Finally, we determine the defects using labelling method. From various experiments using TFT-LCD panels, the proposed algorithm shows superior results.

A Study on Oxygen Precipitation in Heavily Boron Doped Silicon Wafer (고농도 붕소의 도핑된 실리콘 웨이퍼에서의 산소석출에 관한 연구)

  • 윤상현;곽계달
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.9
    • /
    • pp.705-710
    • /
    • 1998
  • Intrinsic gettering is usually to improve wafer quality, which is an important factor for reliable ULSI devices. In order to generate oxygen precipitation in lightly and heavily boron doped silicon wafers with or without high $^75 As^+$ ion implantation, the 2-step annealing method was adopted. After annealing, the were cleaved and etched with th Wright etchant. The morphology of cross section on samples was inspected by FESEM(field emission scanning electron microscopy). The morphology of unimplanted samples was rater rough than that of the implanted. Oxygen precipitation density observed by an optical microscope in lightly boron doped samples was about 3$\times10^6/cm^3$. However, in heavily boron doped samples, the density of oxygen precipitation was largest at $600^{\circ}C$ in 1st annealing, and decreased abruptly until $800^{\circ}C$, But it increased slightly at $1000^{\circ}C$ and was independent with the implantation.

  • PDF

Review on Zeolite MFI Membranes for Xylene Isomer Separation (제올라이트 MFI 자일렌 분리막 연구 동향)

  • Kim, Donghun
    • Membrane Journal
    • /
    • v.29 no.4
    • /
    • pp.202-215
    • /
    • 2019
  • Molecular sieve membranes separate molecules based on their size and/or shape and have been of high interest, due to their potentially high energy efficiency and high selectivity. Zeolite MFI membrane is one of the most-studied molecular sieve membranes and has affected following studies on other molecular sieve membranes. This review discusses the technical developments on the control of morphology, microstructure, and defect of MFI membranes, which have significantly improved xylene isomer separation performances. These include crystal morphology control, effective secondary growth, seed coating method, crystal orientation control, heteroatom doping, and defect healing method.

Vulvar Reconstruction Using Keystone Flaps Based on the Perforators of Three Arteries

  • Yunjae Lee;Sanghun Lee;Dongkyu Lee;Hyeonjung Yeo;Hannara Park;Hyochun Park
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.724-728
    • /
    • 2022
  • Various flaps are used to reconstruct skin and soft tissue defects of the vulva following resection of malignancies. Whenever possible, reconstruction using local flaps is the standard treatment. Here, we describe vulvar defect reconstruction using keystone flaps. Standard keystone flaps are based on randomly located vascular perforators. However, we designed a keystone flap that includes perforators of three named arteries (the anterior labial artery of the external pudendal artery, cutaneous branches of the obturator artery, and posterior labial artery of the internal pudendal artery) and the pudendal nerve, which accompanies the internal pudendal artery. Four patients with squamous cell carcinoma and extramammary Paget's disease of the vulva underwent radical vulvectomy and keystone flaps including perforators of three arteries. Depending on the morphology of the defects, keystone flaps were used with different designs. For elliptical and unilateral vulvar defects, a standard keystone flap was designed, and for defects on both sides of the vulva, a double opposing keystone flap was used. For oval defects, the omega variant keystone flap was designed, and when the morphology of the defect needed rotation of the flap, a rotational keystone flap was designed. All the patients showed good function and sensation, with an acceptable cosmetic appearance.

Direct Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Objective : Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filters during CAS. Methods : A total of 107 patients underwent CAS with use of a distal protection filter. Angiographic carotid plaque surface morphology was classified as smooth, irregular, and ulcerated. To determine predictable factors of filling defect in the protection filters, 11 variables were retrospectively analyzed which might influence filling defect in the protection filters during CAS. Results : Filling defects during CAS were presented in the 33 cerebral protection filters. In multivariate analysis, angiographic ulceration [odds ratio (OR), 6.60; 95% confidence interval (CI) : 2.24, 19.4; p=0.001], higher stenosis degree (OR, 1.06; 95% CI : 1.00, 1.12; p=0.039), and coexistent thrombus (OR, 7.58; 95% CI : 1.69, 34.05; p=0.08) were highly associated with filling defect in the cerebral protection devices during CAS. Among several variables, angiographic surface ulceration was the only significant factor associated with flow stagnation during CAS (OR, 4.11; 95% CI : 1.33, 12.72; p=0.014). Conclusion : Plaque surface morphology on carotid angiography can be a highly sensitive marker of plaque instability during CAS. The independent risk factors for filling defect in the filter devices during CAS were plaque ulceration, stenosis degree, and coexistent thrombus.