• Title/Summary/Keyword: defect inspection

Search Result 597, Processing Time 0.024 seconds

Review of the Current infrared Thermorgraphy Techniques for Detecting Defects in Civil Structures (토목 구조물의 손상 검출을 위한 적외선 열화상 기법의 적용 사례 분석)

  • Sim, Jungi;Zi, Goangseup;Park, Jin-Hyung;Cho, Hyo-Nam;Lee, Jong Seh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.71-83
    • /
    • 2008
  • In this paper, the basic principle, the application and the limitation of Infrared thermography technique to detect defects in different kinds of concrete structures are reviewed. Considered are voids beneath the concrete surface with experiments, delamination between concrete surface and fiber reinforced polymer sheet, the deterioration of steel bars in reinforced concrete, surface defects in historical buildings, pavements, bridges, and railway track graves. As a result, we conclude that infrared thermography methods are useful for fast detecting defects; however, they are influenced by environmental factors, specially temperature. Therefore it is recommended to use the infrared thermography technique with other NDT equipments to expect better result.

The Efficiency of External Heat Sources for Infrared Thermography Applied Concrete Structures and the Improvement of the Defect-identification (열화상 기법을 이용한 콘크리트 구조물 결함 검출시 열원의 효율 비교 및 결함검출 능력 향상)

  • Sim, Jun-Gi;Moon, Do-Young;Chung, Lan;Lee, Jong-Seh;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.169-179
    • /
    • 2009
  • The purpose of this paper is to find an efficient heat source to amplify the surface temperature of damaged concrete structures for infrared thermography. we compare two different heat sources of far-infrared lamp and halogen lamp each other for their efficiency. The two heat sources were applied to the concrete specimens. Two different concrete specimens were used: one was the concrete containing internal void and the other was wrapped with partially unbonded fiber reinforced polymer sheet. it was found that the far-infrared lamp was more efficient than the halogen lamp. In addition, we propose a new algorithm to make the damage zone displayed clear in the image obtained from the thermographic operation. The algorithm is a combination of Gauss filtering process and the Prewitt mask operation.

AN EXPERIMENTAL STUDY ON THE EFFECTS OF OXIDIZED CELLULOSE COVERAGE ON THE CORTICAL BONY DEFECTS (피질골 골결손부에서 Oxidized Cellulose 피개의 영향에 관한 실험적 연구)

  • Kim, Hoi-Jong;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.112-126
    • /
    • 1998
  • In dentistry, bony defects can be formed by cyst, tumor, inflammation, trauma and surgery in maxilla and mandible. If the overlying soft tissue invades and preoccupies the jaw bony defects, regenerated bony tissue same as adjacent bone can not replace whole space of the defects, thus preventing osteogenesis from occurring. Guided bone regeneration(GBR) is based on the prevention of overlying soft tissue from entering the bony defect during the initial healing periods. E-polytetrafluoroethylene(e-PTFE) is one of an effective and widely used barrier membrane for GBR, but it has the disadvantages such as surgical removal and high price. To overcome such disadvantages of e-PTFE, many investigators have proposed various absorbable barrier membranes. Inexpensive oxidized cellulose($Surgicel^{(R)}$) membrane was shown to have potential for use as an absorbable barrier membrane for regenerative procedure and it would not require surgical removal. The purpose of this study is to investigate the absorption periods of oxidized cellulose at the implant site and usefulness as a mechanical barrier, preventing the ingrowth of the overlying soft tissue into the bony defects. Two bony defects were made in each tibia of a dog using drill and one defect covered with oxidized cellulose and the other covered with periosteum directly as control. The experimental animals were sacrificed at 1st-7th, 10th, 14th, 21th, 28th day postoperatively, Inspection of the specimens was done to evaluate gross changes. Specimens were examined histopathologically by hematoxylin-eosin and Masson's trichrome staining under light microscope. The results were as follows : 1. There was no significant differences of inflammatory reaction between the experimental and the control group. 2. The resorption of oxidized cellulose was almost completed within 14th day. 3. Histologically, bone formation in the experimental group was somewhat more than that of the control group at 10th, 14th, 21th and 28th day postoperatively. The bone forming pattern of the experimental group was more regular than that of the control group. 4. There was no evidence of soft tissue invasion into the bony defect in the experimental group. In conclusion, oxidized cellulose membrane might be used as an alternative absorbable barrier membrane to prevent overlying soft tissue invasion into the bony defects.

  • PDF

Study on MFL Technology for Defect Detection of Railroad Track Under Speed-up Condition (증속에 따른 누설자속기반 철도레일 결함탐상 기술 적용성 검토)

  • Kang, Donghoon;Oh, Ji-Taek;Kim, Ju-Won;Park, Seunghee
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.5
    • /
    • pp.401-409
    • /
    • 2015
  • Defects generated in a railroad track that guides the railroad vehicle have the characteristic of growing fast; as such, the detection technology for railroad track defects is very important because defects can eventually cause mass disasters like derailments. In this study, a speed-up test facility was fabricated to investigate the feasibility of using magnetic flux leakage (MFL) technology for defect detection in a railroad track under speed-up condition; a test was conducted using a railroad track specimen with defects. For this purpose, an MFL sensor head dedicated to the configuration of the railroad was designed and test specimens with artificial defects on their surfaces were manufactured. Using the test facility, a speed-up test ranging from 4km/h to 12km/h was performed and defects including locations were successfully detected from MFL signals induced by defects with enhanced visibility by differentiating raw MFL signals. In the future, it should be possible to apply this system to a high-speed railroad inspection car by improving the lift-off stability that is necessary for speed-up of the developed MFL sensor system.

The Analysis of Multilayered Media Using Ultrasonic Microscopy (초음파 현미경을 이용한 다층구조물의 해석)

  • Ko, Dae-Sik;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.5-13
    • /
    • 1990
  • In this paper, 50MHz reflection ultrasonic microscope system with small aperture acoustic lens has been constructed in order to study the defects which lay deep in thick specimens, and acoustic images of multilayered media have been analyzed. Output characteristics of this system for multilayered media have been influenced by acoustic attenuation, aberration in specimen, type of lens and the properties of a defect, and it has been used for image processing of the multilayered I.C. and the bonding layer. In experimental results, it has been shown that small aperture ultrasonic microscope system was powerful tool for inspection of thick specimens such as electronic device, bonding layer, quality of ceramic materials.

  • PDF

Implementation of Facility Maintenance Management System using Smart Phones (스마트 폰을 이용한 시설물 유지관리 시스템 구현)

  • Joo, Young-Do
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.191-197
    • /
    • 2013
  • Recently, the demand for mobile systems is remarkably growing due to the explosive spread of smart phones. The mobile system based on the smart phones enables the real time communication and business process by utilizing the on-line information on the spot anytime and anywhere. This paper proposes a development model to use android-based mobile applications to be applicable to the facility defect maintenance management in apartment buildings. The proposed methodology aims to implement an incorporated system to bind the web-based system and the mobile system in systematic interaction in order to feasibly realize the concept of mobile office.

Advanced performance evaluation system for existing concrete bridges

  • Miyamoto, Ayaho;Emoto, Hisao;Asano, Hiroyoshi
    • Computers and Concrete
    • /
    • v.14 no.6
    • /
    • pp.727-743
    • /
    • 2014
  • The management of existing concrete bridges has become a major social concern in many developed countries due to the large number of bridges exhibiting signs of significant deterioration. This problem has increased the demand for effective maintenance and renewal planning. In order to implement an appropriate management procedure for a structure, a wide array of corrective strategies must be evaluated with respect to not only the condition state of each defect but also safety, economy and sustainability. This paper describes a new performance evaluation system for existing concrete bridges. The system evaluates performance based on load carrying capability and durability from the results of a visual inspection and specification data, and describes the necessity of maintenance. It categorizes all girders and slabs as either unsafe, severe deterioration, moderate deterioration, mild deterioration, or safe. The technique employs an expert system with an appropriate knowledge base in the evaluation. A characteristic feature of the system is the use of neural networks to evaluate the performance and facilitate refinement of the knowledge base. The neural network proposed in the present study has the capability to prevent an inference process and knowledge base from becoming a black box. It is very important that the system is capable of detailing how the performance is calculated since the road network represents a huge investment. The effectiveness of the neural network and machine learning method is verified by comparing diagnostic results by bridge experts.

Optical metrology for resonant surface acoustic wave in RF device (RF 소자의 표면탄성파 공진에 대한 광학적 측정)

  • Park, Jun-Oh;Jang, Won-Kweon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3435-3440
    • /
    • 2010
  • Unlike the electric method capable of checking only product defect, the real time optical metrology is suggested for measuring and visualizing vibration with respect to position of surface acoustic wave in RF device. The measuring limits and conditions for surface acoustic wave is given, and the interference and diffraction due to RF signal are analyzed by optical interpretation. A single mode laser and a 105MHz-center-frequency repeater filter were employed for experiments and theoretical analysis. In this paper, the optical metrology providing visual energy distribution and real time inspection for surface acoustic wave is proposed for development of high quality multi-service and multi-frequency RF module.

Facility Maintenance Management System Using a Mobile Application (모바일 어플리케이션을 이용한 시설물 유지관리 시스템)

  • Joo, Young-Do
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.5
    • /
    • pp.1145-1151
    • /
    • 2012
  • Recently, the demand for mobile system is growing owing to the spread of smart phones to enable the real-time business process. This paper proposes the real-time facility maintenance management system using an android-based mobile application to apply to the facility defect/maintenance field for the apartment building complex. The proposed system model aims to develop the comprehensive management system to integrate the web and mobile system to lead to the realization of mobile office. The security measures required in the mobile system are technically analyzed and implemented on the system.

Template Check and Block Matching Method for Automatic Defects Detection of the Back Light Unit (도광판의 자동결함검출을 위한 템플릿 검사와 블록 매칭 방법)

  • Han Chang-Ho;Cho Sang-Hee;Oh Choon-Suk;Ryu Young-Kee
    • The KIPS Transactions:PartB
    • /
    • v.13B no.4 s.107
    • /
    • pp.377-382
    • /
    • 2006
  • In this paper, two methods based on the use of morphology and pattern matching prior to detect classified defects automatically on the back light unit which is a part of display equipments are proposed. One is the template check method which detects small size defects by using closing and opening method, and the other is the block matching method which detects big size defects by comparing with four regions of uniform blocks. The TC algorithm also can detect defects on the non-uniform pattern of BLU by using revised Otsu method. The proposed method has been implemented on the automatic defect detection system we developed and has been tested image data of BLU captured by the system.