• 제목/요약/키워드: deck slab

검색결과 254건 처리시간 0.028초

Mechanical behavior of steel-concrete composite decks with perfobond shear connectors

  • Allahyari, Hamed;Dehestani, Mehdi;Beygi, Morteza H.A.;Neya, Bahram Navayi;Rahmani, Ebrahim
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.339-358
    • /
    • 2014
  • Exodermic deck systems are new composite steel grid deck systems which have been used in various projects during the past decade. One of the eminent features of this system is considerable reduction in the structure weight compared to the ordinary reinforced concrete decks and also reduction in construction time by using precast Exodermic decks. In this study, dynamic properties of the Exodermic deck bridges with alternative perfobond shear connectors are investigated experimentally. In order to evaluate the dynamic properties of the decks, peak picking and Nyquist circle fit methods are employed. Frequencies obtained experimentally are in good agreement with the results of the finite-element solution, and the experimental results show that the first mode is the most effective mode among the obtained modes. The first four modes are the rigid translational motion modes, and the next two modes seem to be rigid rotational motion modes around a horizontal axis. From the 7th mode onwards, modes are flexible. The range of damping ratios is about 0.5%. Furthermore, the static behavior of the Exodermic decks under a static load applied at the center of the decks was investigated. Failure of the decks under positive bending was punching-shear. The bending strength of the decks under negative bending was about 50 percent of their strength under positive bending. In addition, the weight of an Exodermic deck is about 40% of that of an equivalent reinforced concrete slab.

지진하중을 고려한 장대레일교량의 궤도-교량 상호작용에 대한 안전성 평가 (Safety Evaluation on Interaction between Track and Bridge in Continuous Welded Railway Bridge Considering Seismic Load)

  • 심윤보;김연태;김상철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.40-48
    • /
    • 2016
  • 본 연구는 지진이 발생할 경우 장대레일교량에 있어 레일과 상판 간의 종방향 상호작용에 미치는 영향을 검토하기 위한 것으로, 해석모델에 여러 하중조합과 함께 지진하중을 적용함으로써 대상 철도교량 레일에서의 축방향 부가응력과 레일-상판 간 상대변위의 변화를 산출하였다. 해석 결과, 본 연구 대상 철도교량의 경우 철도시설공단에서 제시하고 있는 표준응답스펙트럼을 적용할 때 레일부가응력은 대부분의 하중조합에 대해 허용기준 내의 값을 보이고 있는 반면, 레일-상판 상대변위는 공단에서 제시하는 허용기준을 초과하고 있는 것으로 나타났다. 따라서 레일-상판 상대변위가 레일부가응력에 비해 상대적으로 더 허용기준을 만족시키기 어렵다는 것을 알 수 있었으며, 아울러 고베 대지진과 같은 큰 규모의 지진이 발생하면 레일부가응력과 레일-상판 상대변위는 허용기준을 충족시키지 못하므로 이에 대한 적절한 내진 대비가 필요하다.

매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보- (Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.235-245
    • /
    • 2004
  • 현재 합성 구조가 사용성 측면에서 경제적이고 작업성이 좋으며, 시공상의 편의성 등의 장점이 있다는 것은 일반화된 사실이지만, 자체의 춤이 깊기 때문에 철골조 건물에 적용하기에 여러 가지 비효율적 측면이 있다. 따라서 본 연구에서는 합성보의 전체 춤을 절감할 수 있도록 철골보의 춤내에 콘크리트를 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 이른바 "슬림플로어" 공법에 대한 연구를 수행하였다. 본 연구는 콘크리트에 매입된 비대칭 철골보를 가지는 부분 합성 슬림플로어 시스템의 휨거동에 관한 것이다. 총 8개의 실대형 실험체를 철골보 춤, 전단연결 유무, 슬래브 유효폭, 및 콘크리트 토핑두께 별로 제작하여 실험을 수행하였다. 실험결과, 별도의 전단연결재를 설치하지 않은 실험체는 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 완전합성보에 비해서 $0.53{\sim}0.95$의 전단합성비를 나타내었다.

유리섬유 보강 플래스틱 Re-Bar 다발로 보강된 1방향 콘크리트 슬래브의 휨거동에 관한 실험적 연구 (Experimental Investigations on the Flexural Behavior of One-Way Concrete Slabs Reinforced with GFRP Re-Bar Bundle)

  • 윤순종;김병석;유성근;정재호;정상균
    • Composites Research
    • /
    • 제16권3호
    • /
    • pp.32-40
    • /
    • 2003
  • 최근 철근의 부식과 관련된 철관콘크리트 바닥판의 내구성에 대한 문제점이 증가되면서 부식에 대한 저항성이 크며, 기존 구조용 재료에 비해 여러 가지 물리적, 역학적 장점을 가진 섬유보강플래스틱을 사용한 보강재의 사용성이 증가되고 있다. 본 연구는 GFRP Re-Bar 다발로 보강된 1방향 슬래브의 휨거동에 관한 실험적 연구로서, 국내에서 개발된 GFRP Re-bar의 인장시험을 수행하였으며, GFRP Re-Bar의 보강량을 증가시켜가며 단위 폭을 갖는 1방향 슬래브 실험체를 제작하고 3등분점 재하실험을 수행하였다. 각 실험체에 대한 이론적인 해석은 철근콘크리트 휨부재의 해석 및 설계방법을 수정, 보완하여 개발된 ACI Committee 440에 따라 수행하였으며, 실험결과와 이론적 해석결과를 비교, 분석하였다. 연구결과 ACI Committee 440에 의해 추정한 각 실험체의 하중­처짐 거동은 실험결과와 비교적 잘 일치함을 알 수 있었으며, FRP Re-Bar로 보강된 콘크리트 바닥판의 설계규준을 확립하기 위해서는 강도에 대한 한계상태뿐만 아니라 처짐 등 사용성에 대한 한계상태가 결정되어야 할 것이라 생각된다.

Mechanism on suppression in vortex-induced vibration of bridge deck with long projecting slab with countermeasures

  • Zhou, Zhiyong;Yang, Ting;Ding, Quanshun;Ge, Yaojun
    • Wind and Structures
    • /
    • 제20권5호
    • /
    • pp.643-660
    • /
    • 2015
  • The wind tunnel test of large-scale sectional model and computational fluid dynamics (CFD) are employed for the purpose of studying the aerodynamic appendices and mechanism on suppression for the vortex-induced vibration (VIV). This paper takes the HongKong-Zhuhai-Macao Bridge as an example to conduct the wind tunnel test of large-scale sectional model. The results of wind tunnel test show that it is the crash barrier that induces the vertical VIV. CFD numerical simulation results show that the distance between the curb and crash barrier is not long enough to accelerate the flow velocity between them, resulting in an approximate stagnation region forming behind those two, where the continuous vortex-shedding occurs, giving rise to the vertical VIV in the end. According to the above, 3 types of wind fairing (trapezoidal, airfoil and smaller airfoil) are proposed to accelerate the flow velocity between the crash barrier and curb in order to avoid the continuous vortex-shedding. Both of the CFD numerical simulation and the velocity field measurement show that the flow velocity of all the measuring points in case of the section with airfoil wind fairing, can be increased greatly compared to the results of original section, and the energy is reduced considerably at the natural frequency, indicating that the wind fairing do accelerate the flow velocity behind the crash barrier. Wind tunnel tests in case of the sections with three different countermeasures mentioned above are conducted and the results compared with the original section show that all the three different countermeasures can be used to control VIV to varying degrees.

강박스거더교 가로보와 세로보 합리화 연구 (Design Improvements for Crossbeams and Stringers of Steel Box Girder Bridge)

  • 길흥배;강상규;조준상
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 강재 박스거더교의 바닥틀을 구성하며, 바닥판의 활하중과 고정하중을 지지하는 가로보와 세로보의 설계 합리화를 위한 연구가 수행되었다. 가로보는 일반 거더교의 수직 브레이싱 규정을 근거로 6m 이하의 간격으로 조밀하게 배치되며, 세로보는 가로보 사이에 배치된다. 또한 가로보와 세로보는 바닥판과 슬래브 앵커로 연결되지만, 허용응력은 횡비틀림좌굴의 발생을 고려하여 보수적으로 결정 된다. 강박스거더교의 경제성을 도모하고 가설 및 유지관리시의 편의성을 증진시키기 위하여 가로보의 간격을 10m로 증가시켜 세로보와 가로보 의 단면 및 이음부 설계에 대해 검토하였다. 세로보의 지간이 증가함에 따라 응력이 증가하여 고강도의 강재를 사용해야 하지만, 제작 및 유지관리면에서 세로보의 지간을 증가시키는 것이 바람직하며, 경제적으로도 유리할 것으로 판단된다. 바닥판과 세로보 및 가로보의 부착 강도를 충분히 확보하기 위해서는 기존에 사용되고 있는 슬래브 앵커 보다는 전단연결재를 활용하는 것이 바람직한 것으로 판단된다.

격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구 (Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint)

  • 신현섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.10-21
    • /
    • 2014
  • 프리캐스트 방식에 의해 제작이 가능한 격자형 강합성 바닥판의 이음부는 콘크리트 전단키와 고장력볼트 체결로 구성될 수 있으며, 이와같은 이음부 자체에 대한 휨 및 전단성능은 부재요소에 대한 실험을 통해 분석된 바 있다. 본 연구에서는 실제 바닥판 구조시스템에서 이음부에 의한 횡방향 하중전달 거동을 분석하고자, 길이 2.5m 및 폭 1m의 단위 바닥판 모듈 한쌍에 이음부를 설치한 실험체를 제작하고 중심 및 편심가력 휨실험을 하였다. 이음부에 하중이 직접 가해지는 중심재하 조건에서 고장력볼트의 설치개수가 30cm 간격 9개에서 60cm 간격 4개로 줄어 들 경우, 재하단계에 따라 이음부의 회전이 비교적 더 크게 증가하고, 이에 따라 바닥판 횡방향으로의 하중전달 정도가 감소함을 알 수 있었다. 그러나, 한쪽 바닥판의 중심에 집중하중이 가해지는 편심재하 조건의 경우에는 횡방향 하중전달 거동에 큰 차이가 없었다. 하중 재하방법별로 이음부의 거동을 비교한 결과, 집중하중에 대한 바닥판 횡방향으로의 하중분배 및 전달량은 이음부 자체의 성능뿐만 아니라 바닥판 슬래브의 펀칭전단에 의해서도 제한되는 것으로 분석되었다. 또한, 펀칭 전단파괴가 발생할 때까지 이음부의 고장력볼트가 항복하지 않은 점을 고려할 때, 이음부 고장력볼트의 설치개수를 4개에서 9개로 증가시키는 것은 실질적으로 강도 보다는 이음부 및 바닥판의 휨강성 성능 증가에 더 큰 영향을 미치는 것으로 사료된다.

소수주형 철도교의 궤도시스템 변화에 따른 동적거동 분석 (A Dynamic Behavior Analysis of composite Few Plate Girder Railway Bridge under Variety of Track systems)

  • 이홍준;최정열;엄맥;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1171-1176
    • /
    • 2005
  • The latest technical development of steel plate girder railway bridge are developing in ways to maximize its durability of materials in use of high strength steel and efficiency of maintenance and management by the introduction of simplified and standardization ideas. In addition to this, it is also expected to reduce the cost of bridge construction and to simplify the process of bridge manufacturing. Referring to this, composite few plate girder railway bridge is highly recommendable that is very economical with the fine exterior. In this paper, it will analyse the variation of dynamic behavior of existing composite few plate girder railway bridge with ballast caused by modified Slab Track through interpretation of limited enzyme in order to obtain the existing data for improvement of Slab Track system from Ballast Track system. Consequently, it can help maximize economic efficiency and structural capability. As a results, although the natural frequency by modified Slab Track are decreased, it is hardly influencing on the safety of railway bridges. It is also evident in the case of slab deck with a reduced scale in comparison with Ballast Track. Therefore, it is expected to reduce the cost of a railway bridge plan. And, it can expect the synergistic effect of the ensure long term durability of bridge caused by decreased stresses of bottom flange due to reduced dead load. As a result, the analytical study are carried out to investigate the composite few plate girder railway bridge could be the optimal design method for the dynamic safety of a girder section.

  • PDF

경량콘크리트를 사용한 철선일체형 바닥구조의 휨내력 및 전단내력 실험적 평가 (An Experimental Evaluation of Bending and Shear Resisting Strengths for Wire-Integrated Deck Plate System using Lightweight Concrete)

  • 이성희;방중석;원용안;류재용;최성모
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.275-282
    • /
    • 2011
  • 최근 내진설계의 발달과 친환경 건설자재에 대한 관심으로 건물의 자중을 줄이기 위한 경량콘크리트에 대한 관심이 높아지고 있으며, 증축건물을 중심으로 경량콘크리트를 이용한 설계가 점차 증가하는 추세에 있다. 따라서 본 연구는 철선일체형 데크플레이트와 경량콘크리트를 사용한 바닥구조시스템의 휨내력과 전단내력을 평가하기 위해 하부 강판 플레이트의 설치유무를 변수로 4개의 실험체를 제작하여 구조실험을 수행하였다. 이를 통해 경량콘크리트를 이용한 합성바닥구조의 구조성능은 KCI(2007)의 설계기준을 만족하는 것으로 나타났다.

경량콘크리트를 사용한 합성 철선트러스 데크의 푸쉬 아웃 성능 실험 (Push-out Performance Test of Composite Steel Truss Deck using Light Weight Concrete)

  • 최병정;문효진;한홍수;한권규
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.15-26
    • /
    • 2009
  • 본 연구의 목적은 실험을 통하여 복합 데크슬라브 시스템에 사용되는 쉬어 커넥터의 전단 성능을 연구하는 것이다. 경량콘크리트와 선조립 철선트러스를 사용하여 복합 데크슬라브를 가진 6개의 실험체를 제작하여, Push-out test를 실시하였다. 실험체는 철선트러스와 아연강판의 설치유무로 구분하여 DP, NDP, Solid의 세 가지 그룹으로 분류하였다. 전단 성능 실험을 통하여 실험체의 파괴양상, 거동, 하중-변위 관계를 분석하고, 실험값과 기존의 기준식을 비교하였고, 다음과 같은 결론을 도출하였다. 첫째, DP 및 NDP 계열의 파괴는 스터드 파괴이며, Solid계열의 파괴는 콘크리트 파괴였다. 둘째, 전단내력을 확인한 결과 NDP계열이 가장 우수한 내력을 갖는 것으로 나타났다. 셋째, 각 실험체의 스터드는 유사한 전단거동을 하였고, 스터드와 콘크리트는 항복시점까지 일체 거동을 하였다. 넷째, 다른 두 개의 기준식과 비교했을 때 ACI318-05의 기준식이 가장 근접한 스터드 전단력을 예측할 수 있는 것으로 확인되었다.