• 제목/요약/키워드: dead space

검색결과 277건 처리시간 0.011초

기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향 (The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation)

  • 유정숙;윤선희;송계희;민열하
    • 대한간호학회지
    • /
    • 제31권1호
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

개심술후 폐의 Physiologic dead space 와 Shunt 의 변화상 추적 (Physiological Dead Space and Shunt Following Open Heart Surgery)

  • 이길노
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.771-779
    • /
    • 1985
  • It has been recognized that the proper matching of ventilation and perfusion within the lung is essential for the efficient exchange of gases following open heart surgery. Physiologic shunt reflects the amount of blood going to lung units with inadequate ventilation and these are also areas of the lung with adequate ventilation but inadequate blood flow. This can be quantified by measuring physiological dead space. From January to August 1985, The physiologic dead space and shunt during postoperative course had been taken in 30 patients of open heart surgery in Soonchunhyang University Hospital. Twenty cases had congenital heart disease and acquired valvular heart disease were noticed in 10 cases. The physiological dead space and shunt during postoperative periods were calculated and we made 5 items of conclusion: 1. There is high probability of ventilation-perfusion mismatch in the acquired heart disease group compared to the congenital group. 2. Duration of the CPB can exert significant influences in the physiological dead space but less in the shunt fraction. 3. There is positive relationship between Qs/Qt and Vd/Vt in the group B [CPB>90 min.] but less reliable in correlation. 4. Perfusion impairment is more significant in the diminished pulmonic blood flow group compared to the increased pulmonic blood flow [Qp/Qs>2.0] group. 5. There is no significant ventilation-perfusion mismatch within the lung during all postoperative courses.

  • PDF

공간벡터 전류제어 기법을 이용한 벡터제어형 인버터의 dead time 보상 (Dead Time Compensation of Vector Controlled Inverter Using Space Vector Modulation Method)

  • 홍기필;오원석;김영태;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.265-269
    • /
    • 1994
  • The switching dead time avoiding a bridge leg short circuit in PWM voltage source inverter produces distortions of the controlling inverter output performance such as current waveform, voltage vector, and torque. In this paper, the influence of dead time is investigated. The on-line space voltage vector modulation method is used for current controller. It is possible to compensate dead time by space voltage vector modulation which generates additional pulse compensating voltage distortion caused by dead time. In addition, narrow pulse which is generally neglected can be compensated. All the algorithms, including field-oriented control are performed by one chip microprocessor 80C196MC and DSP TMS320C31. Experimental results probe that the proposed scheme provides a good inverter output performance.

  • PDF

Analysis and Compensation Control of Dead-Time Effect on Space Vector PWM

  • Shi, Jie;Li, Shihua
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.431-442
    • /
    • 2015
  • Dead-time element must be set into space vector pulsed width modulation signals to avoid short circuits of the inverter. However, the dead-time element distorts the output voltage vector, which deteriorates the performance of electrical machine drive system. In this paper, dead-time effect and its compensation control strategy are analyzed. Based on the analysis, the voltage distortion caused by dead-time is regarded as two disturbances imposed on dq axes in the rotor reference frame, which degenerates the current tracking performance. To inhibit the adverse effect caused by the dead-time, a control scheme using two linear extended state observers is proposed. This method provides a strong ability to suppress dead-time effects. Simulations and experiments are conducted on a permanent magnet synchronous motor drive system to demonstrate the effectiveness of the proposed method.

개의 큰 사강을 갖는 창상에서 무세포성 진피기질의 적용 3례 (Acellular Dermal Matrix for Wound with Large Dead Space in 3 Dogs)

  • 엽경아;변예은;이선태;김희정;조지영;권오경;김진영;강계원;김완희
    • 한국임상수의학회지
    • /
    • 제27권3호
    • /
    • pp.299-301
    • /
    • 2010
  • 광범위한 사강과 함께 치유가 지연된 개의 창상에 무세포성 진피기질(Acellular human dermal matrix, ADM)을 적용하였다. 이 치료는 피하 사강을 갖는 창상과 근육면 사이의 창상에 특히 효과적인 치료법이었다. 본 증례에서 ADM 적용시 사강의 크기와 삼출물의 양이 급격히 줄어들었다. 사강이 사라지는 데까지의 평균 기간은 약 10일 이었다. 또한, 이 증례에서는 중증의 염증과 같은 복합증은 확인되지 않았다.

데드 타임 없는 새로운 공간 벡터 전압 변조 인버터에 관한 연구 (A Study on the Novel Space Vector PWM Inverter without Dead time)

  • 서일수;송의호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1169-1171
    • /
    • 2004
  • Voltage source inverters are required dead time to prevent the short current in the dc link. In recent years, the dead time effect has been investigated in many literatures. This paper presents on the novel space vector PWM inverter without dead time. The proposed inverter don't need to sense load current and to calculate for dead time compensation. Transformers are inserted each leg in the proposed inverter. The proposed method is analyzed each mode and then the simulation results verify the proposed method.

  • PDF

새로운 데드타임보상법을 이용한 인버터 출력전압의 합성 (Inverter Output Voltage Synthesis Using Novel Dead Time Compensation)

  • 최종우;설승기
    • 대한전기학회논문지
    • /
    • 제44권4호
    • /
    • pp.453-459
    • /
    • 1995
  • In this paper, a novel dead time compensation method is presented which produces inverter output voltages equal to reference voltages. An experimental result is also presented to demonstrate the validity of the proposed method. It shows that the compensation of the dead time is possible up to a sub-microsecond range. And the reference voltage can be used as a feedback value, which is essential for sensorless vector control and flux estimation. The method is based on space vector PWM strategy and can be carried out automatically by an inverter controller for initial set-up without any extra hardware.

  • PDF

도시 고가도로 하부 공간 재생디자인 연구 (Regeneration Design for the Under-space of Overpass in the City)

  • 남동현;윤지영
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.31-42
    • /
    • 2011
  • This study aimed at exploring the cultural ways to develope the under-space of overpass in the downtown area which has been considered as a dead, unhealthy place. The study process consists of 4 methodological stages. literature review, case study on environmental design of under-space of overpass, questionnaire and statistical analysis and specific study on regional context were conducted to understand the problems of the space and the needs of the community and visitors. The final suggestion based on the research are the natural rest settings including pocket parks with trees and fountain as well as cultural settings with small sized outdoor gallery and open performance stage which can be managed by the community members. The findings of this study would help the dead space in the center of the city regenerate the community in terms of physical, cultural and social environments. Also, this study will show the importance and the methodological approach of the research for the development of the hidden potential space of the city.