• Title/Summary/Keyword: daylight

Search Result 460, Processing Time 0.026 seconds

Effect of LED Lighting Time on Productivity, Blood Parameters and Immune Responses of Dairy Cows (LED 점등시간이 젖소의 생산성, 혈액 매개변수 및 면역 반응에 미치는 영향)

  • Park, Jin-Ryong;Yoon, Nam-Jin;Belal, Shah-Ahmed;Shim, Kwan-Seob
    • Korean Journal of Organic Agriculture
    • /
    • v.26 no.3
    • /
    • pp.515-532
    • /
    • 2018
  • Light is an essential and powerful element to animals. A light-emitting diode (LED) is most efficient in terms of economic benefits. The aim of the present study was to evaluate the effects of LED lighting time on milk production, milk composition, and the immune response of Holstein cows. Forty lactating cows were assigned to four experimental groups: control; natural daylight, treatment; am3-6, pm6-12 and pm6-am6. We found that there was no significant effect on the decrease ratio in milk production among the groups. Milk urea nitrogen (MUN) was significantly decreased in pm6-am6 and pm6-12 than the control. With regard to the hemolytic biochemical analysis, GLU was significantly increased and CRE, T-BIL were significantly decreased in the pm6-12 than the control. IGF-1 levels were significantly increased in pm6-12 compared to other groups. Besides, cortisol was significantly lowered in the pm6-12 than the control, while prolactin, IgA and IgG were not significant among the groups. In addition, catalase and glutathione peroxidase were also significantly increased in pm6-12 than the control. However, antioxidant enzyme activity and superoxide dismutase were not significant among the experimental groups. Therefore, it was concluded that LED lighting time had some impact on blood parameters and immune responses in dairy cows without any changes in milk production.

An Analytical Study on the Flexible Interior Space of Apartments according to Unit Plan Types - Focusing on Apartment Built Since 1998 - (단위평면의 형태요인에 따른 내부공간 가변화에 관한 분석 - 1998년 이후의 아파트를 중심으로 -)

  • Cho, Il-A;Kim, Hyung-Woo
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.120-129
    • /
    • 2006
  • Apartments have become the most popular type of residential building in Korea since the 1960s. The dwelling space should be designed to accomodate various life styles or changing needs of family members. This research is conducted to analyze flexible interior space types of apartments and to improve the architectural planning and design of apartments that can satisfy various needs of residents. In this study, apartments of 10 - 90 pyeongs built in the region of Seoul, between 1998 and 2007, are investigated in terms of the unit plan, the number of open sides, and a distribution of flexible apartment types for each year, Apartments with flexible space are classified into 10 different types, including a flexible type between bedrooms, a flexible type between a bedroom and the livingroom, and a flexible type between the dinning room and the livingroom. According to the composition of unit plans, apartments are also differentiated as a single-corridor type, a double-corridor type, a stairway type, a hall type, and a combination type. According to these classifications, the characteristics of desirable unit plans were analyzed. The results of the analysis showed that, as the unit size of apartments get bigger, the ratio of width/depth of the front side unit plan is increased. This result reflects a trend of high-rise apartments which have an increased number of front-side bays and a shorter depth for better penetration of daylight. In addition, a hall type is found to have a wider front side and shorter depth. According to open sides, a flexible type of the livingroom and the dinning room/kitchen (L-D.K) is found to be most common for the front/back open space, and the livingroom is usually placed on the front/side open space. To meet the changing needs of residents, more research should be conducted on flexible dwelling space.

The Recognition and Segmentation of the Road Surface State using Wavelet Image Processing (웨이블릿 영상처리에 의한 도로표면상태 인식 및 분류)

  • Han, Tae-Hwan;Ryu, Seung-Ki;Song, Wonseok;Lee, Seung-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2008
  • This study focus on segmentation process that classifies road surfaces into 5 different categories, dry, wet water, icy, and snowy surfaces by analyzing asphalt-paved road images taken in daylight. By using the polarization coefficients, the proportions of horizontally polarized components to vertically polarized components, regions with over 1.3 polarization coefficients are classified as wet surfaces. Except for wet surfaces, the decision process a lies time-frequency analysis to other parts by using the third order wavelet packet transform. In addition, by using the average frequency characteristics of dry and icy surfaces from image templates, decide which is closer to a test image, and finally identify dry and icy surfaces. It is confirmed that the reposed estimation and segmentation of recognition on various images. This can be interpreted as an indication that image-only mad surface condition supervision is probable.

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

A Study on the Improvement of Classifying Method of the Sky Conditions for Application of the Daylight at Indoor - The Comparison with Cloud Amount and Measured Solar Horizontal Irradiation in Seoul - (실내 주광 활용을 위한 천공 구분 방법 개선에 관한 연구 - 서울의 전운량과 측정 일사량의 비교를 통해 -)

  • Kim, Yu-Sin;Kim, Hyun-Sun;Hong, Seong-Kwan;Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • Sky cover method can be used to determine sky condition by cloud amount of the Korea Meteorological Administration. And, HCI (Hourly Clearness Index) method is another method determined by measured horizontal global radiation data. The results of the HCI methods of Erbs et al. (1982), Orgill and Hollands (1977) seem to be not good enough because of the air pollution such as smog phenomenon or yellow sand phenomenon and so on. Therefore, HCI should be corrected. The aim of this study is to improve HCI. Therefore, this study is to analyze and compare on the sky conditions from Sky cover method and HCI, and then presents hourly correction factor based on Sky 채팩 method. The results of corrected HCI improved.

Study on the Characteristics of Surface Ozone Distributions and the Ozone Critical Levels to Vegetation in the South Korea (남한 지역의 지면 오존 농도 특성과 식생에 대한 임계값 적용 연구)

  • Koo, Hae-Jung;Park, Soon-Ung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2008
  • Concentration of tropospheric ozone ($O_3$) was investigated for the South Korea. And then the critical ozone levels, expressed as AOT40 (Accumulated exposure over a threshold of 40 ppb) to vegetation have been used in this region within the UNECE (United Nations Economic Commission for Europe) Convention on Long-Range Trans-boundary Air Pollution (CLRTAP). Hourly ozone concentration data from 1996 to 2001 at 26 air monitoring stations was used to estimate the exceedance of the critical levels. It was calculated for daylight hours for each station, and mapped using surface interpolation over the South Korea. The critical levels of ozone have shown the highly exceeded value in the Gyeonggi region, southern coastal region and central inland of the South Korea. It was some different from the typical ozone distribution which represented highly in the western inland and coastal regions. The area exceeding the critical level for crops was founded to be more than 40% of the whole South Korean territory. While that for trees was to be about 17% of the South Korea. The critical ozone critical level was based upon data from experiments on specific species, and thus may not be fully representative for all types of vegetation. Nevertheless, the critical level and its exceedance of the ozone concentration would be one of the useful tools for international agreements on abatement strategies to prevent ecosystem damage.

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

A Study of the Architectural Characteristic Depending upon the Module in the BIPV System (BIPV 시스템에서의 모듈 종류에 따른 건축적 특성 연구 - 채광형 시스템을 중심으로 -)

  • Lee, Eung-Jik;Lee, Chung-Sik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.196-202
    • /
    • 2008
  • Effective climate protection is a most important tasks of our time. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. In this study it was analyzed by the case study the function of the requirement of the BIPV-module as building material and this architectural characteristic according to the kind of the module. Therefore the goal of this study is to get securing the application information of BIPV as windowpane. BIPV modules are manufactured in the form of G/G. In the case of the crystal type the Transparent and the light Transmission is to be adjusted by the spacer attitude of the cell. Although this type could not be optimal for light effect of indoors because of the inequality of shade, the moving shade play makes a dramatic Roomimage by the run of sun. The application of this type would be for canopy, window or roof in the corridor or resounds. With amorphous the type it is to be manufactured simply largely laminar, and thus that will shorten building process. There is a relatively good economy to use and to the window system easily. After the production technology is easy the transparency of the modules to adjust, and the module shows to a high degree constant characteristics of light permeability and transparency. Without mottle of module shade is good the use for the window or roof glazing of office, library, classroom, etc. to adapt. The BIPV modules took generally speaking a function as building material to the daylight use, shading, isolation and also to the sight. That means that BIPV modules have as multifunctional system to sustainable architecture good successes and they are at the same time as Design element for architecture effectively.

  • PDF

The Evaluation of Ceiling Depth Impact on Lighting and Overall Energy Consumption of a Building with Top-lighting System

  • Amina, Irakoze;Kee, Han Ki;Lee, Young-A
    • Architectural research
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • The purpose of this study was to evaluate the variation in building energy predictions caused by simulation settings related to building envelop thickness. The study assessed the ceiling depth impact on skylight energy performance through OpenStudio integrated Radiance and EnergyPlus simulation programs. A ceiling as deep as 1.5 to 3m was analyzed for skylight to roof ratios from 1% to 25%. The results indicated that the building ceiling depth negatively affected the capability of skylights to significantly reduce building energy consumption. Through a parametric analysis, the study concluded that 8%, 9%, 10% and 11% skylight to roof ratio were optimal in terms of total building energy consumption for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. In addition, the results showed that the usually recommended 5% skylight to roof ratio was only efficient when no ceiling depth was included in the simulation model. Furthermore, the study indicated that the building energy saved by the optimal skylight of each ceiling depth decreased as the ceiling depth deepened. The highest total building energy reduction was 9%, 7%, 5% and 3% for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. This study induced that the solar heat gains and daylight visible transmittance by ceiling depth were crucial in the predictions of skylight energy performance and should not be neglected through building simulation simplifications as it is commonly done in most simulation programs' settings.

A Study of Supply Patterns and Residential Characteristics of Urban-type Housing in Seoul (도시형생활주택의 공급현황 및 거주특성 연구 - 서울시 공급사례를 중심으로 -)

  • Lee, Jae-Su;Seong, Su-Youn;Lee, Dong-Hoon
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.1-9
    • /
    • 2014
  • This study investigates supply patterns and residential characteristics of the Urban-type Housing in Seoul. There have been 3,336 buildings and 71,790 housing units approved until the end of 2012. One-room apartments and small units less than 30 $m^2$ of residential area amount to 81% and 82% of total units, respectively. Major findings are as follows. First, single- and two-person households less than 30 years of age are mostly lived in the housing. Respondents are mainly professional and white-collar (43%) and service and sales workers (27%). Most of them are mid-income classes (67%), which is twice more than that of single- and two-person households in Seoul. They pay 672 thousand won in rent more than average rent of mid-income class. The rent to income ratios are 29.9% for single households and 24.5% for two-person households, which are higher than that of mid-income bracket. Third, their satisfaction level is relatively high in internal environment and access to public service facilities, but not in external environment and community service facilities. They are satisfied with security and daylight, walking and safety, access to public transport and parking space, but not with noise and vibration, natural environment, access to park and cultural and sports facilities, and most community service facilities. It is necessary to reexamine the articles of deregulation and prepare design standards while considering different housing and locational types.