인공위성을 이용한 국내 일사량 분포 예측 (Estimation of Solar Radiation Distribution in Korea Using a Satellite)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.99-106
    • /
    • 2011
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system, it is essential to utilize the solar radiation data as an application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth"s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2009. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is 3.56 kWh/ $m^2$/day and estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

국내 태양에너지 자원 정밀분석 (A Detailed Analysis of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.63.1-63.1
    • /
    • 2010
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system and solar thermal power system, it is essential to utilize the solar radiation data as a application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2009. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is $3.56kWh/m^2/day$.

  • PDF

1985년부터 2014년까지 대구의 측정 수평면전일사량과 기상 데이터의 경향 및 상관관계 분석 연구 (Analytical Study on Relationships and Characteristics of Global Solar Irradiance and Meteorological Data measured in Daegu during 1985 to 2014)

  • 조민철;임하은;곽재은;강준모;황동현;김정배
    • 융복합기술연구소 논문집
    • /
    • 제7권2호
    • /
    • pp.7-12
    • /
    • 2017
  • At present, the Korea Meteorological Administration (KMA) measures the horizontal solar irradiation and meteorological data with time in 33 areas. Among these measured data, this study analyzed the tendency of applying the new analysis method by using the horizontal solar irradiation and meteorological data with the time which was measured in many regions across the country for thirty years from 1985 to 2014. The method applied to the analysis is to compare the value of the annual total horizontal solar irradiance and meteorological data for one year with the value of those for the previous year of each year, and give +1 when it is higher, and -1 when it is lower. The characteristics and relationships the horizontal solar irradiation and meteorological data in Daegu were evaluated and analyzed. Through the analysis results, the analysis method applied in this study could be well describe the characteristics and relationships of the solar irradiance and meteorological data during some years.

국내 기상 측정결과를 이용한 일사량 예측 방법 기초 연구 (A Basic Study to Predict Solar Insolation using Meteorological Observation Data in Korea)

  • 황보성;김하양;김정배
    • 융복합기술연구소 논문집
    • /
    • 제4권2호
    • /
    • pp.27-33
    • /
    • 2014
  • To well design the solar energy system using solar energy, the correlation to calculate solar irradiation is basically needed. So, this study was performed to reveal the relationships between the solar irradiation and four meteorological observation data(dry bulb temperature, relative humidity, sunshine duration, and cloud cover) which are different from previous other researches. And then, we finally proposed the first order non-linear correlation from the measured solar irradiation using four meteorological observation data with MINITAB. To show the deviation of the solar irradiation between measured and calculated, this study compared using the daily total solar irradiance and the maximum peak value. From those results, the calculation error was estimated about maximum 25.4% for the daily total solar irradiance. The error of the solar irradiation between measured and calculated was made from the curve fitting error. So, solar irradiation prediction correlation with higher accuracy can be obtained using 2nd or higher order terms with four meteorological observation data.

국내 태양열시스템 설치를 위한 성분일사량 분석 (Analysis of Solar Radiation Components for the Installation of Solar Thermal System in Korea)

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.12-18
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since January, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The theoretical analysis of solar radiation as a component has compared with the experimental data obtained by the KIER station. The Result of simulation analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,457cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

국내 종합일사량의 성분분석 (Analysis of Total Radiation Components in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.67.1-67.1
    • /
    • 2011
  • Knowledge of the solar radiation components and classified wavelength are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high photo-dynamic efficiency achievable only at the higher intensities. In order to estimate the performance of concentrating solar systems, it is necessary to know the intensity of the beam radiation, as only this components can be concentrated, and The new solar system can generate electricity from ultraviolet and infrared light as well as visible light. The Korea Institute of Energy Research(KIER) has began collecting solar radiation components data since January, 1988, and solar radiation classified wavelength data since November, 2008. KIER's solar radiation components and classified wavelength data will be extensively used by concentrating solar system users or designers as well as by research institutes.

  • PDF

에틸렌글리콜 혼합액을 사용하고, 태양열을 보조열원으로 하는 이중효용 흡수식 시스템의 난방 특성해석 (Analysis of Thermodynamic Design Data for Heating of Double - Effect Solar Absorption System using LiBr - water and Ethylene Glycol Mixture)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.51-61
    • /
    • 2002
  • Analysis of thermodynamic design data of double effect solar absorption heat pump system for heating has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data. enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture (H2O: CHO ratio 10:1 by mole) by computer simulation. The obtained results, COP and mass flow ratio of the water-lithium bromide-ethylene glycol system, are compared with data for the water-Libr pair solution.

국내(國內) 일사량(日射量) 측정(測定)데이타의 정확도(正確度) 평가(評價) 및 보정(補正) (A Accuracy Evaluation & Rehabitation of Domestic Solar Insolation Data by Field Measurement)

  • 조덕기;조서현;최영희;오정무
    • 태양에너지
    • /
    • 제8권1호
    • /
    • pp.107-121
    • /
    • 1988
  • The Korea Institute of Energy and Resources (KIER) has begun collecting horizental insolation data since May, 1982 at different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by the solar system users as well as by research institutes. But, the quality of the solar radiation data is not always good. This reports on an attempt to identify systematic error in such data using clear-day analysis for data rehabilitation. Clear-day analysis is successful in uncovering solar radiation data of questionable quality. It is not proven that rehabilitation process can improve the quality of data for daily or monthly means but it is suggested that the method can be used to improve the quality of data for monthly means of several years for use in many applications of solar energy planning. Earlier studies finding a maximum ETR of about 0.80 are confirmed.

  • PDF

태양열 난방시설 신뢰도 평가 에 관한 연구 (Analyses of Reliability for a Typical Solar Heating System)

  • 장광규;전문헌
    • 대한기계학회논문집
    • /
    • 제7권3호
    • /
    • pp.241-248
    • /
    • 1983
  • In the present work a time-dependent reliability model for a typical solar domestic hot water and heating system is developed using the method of Fault Tree Analysis and existing mathematical techniques. The reference system used in this analysis is a typical solar heating system. The system reliability structure has been identified with the aid of Fault Tree methods. In addition, a simulation of the solar system reliability has been performed employing the Monte Carlo method. In the computer simulation, failure rate data such as WASH-1400, MIL-HDBK-217B, and Green and Bourne are used as input data. These results show that the developed reliability model is capable of expressing the primary failure phenomena of the solar heating and domestic hot water system.

국내 일사량 자원 특성분석 (A Characteristic Analysis of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.61 kWh/$m^2$/day and the yearly mean 5.38 kWh/$m^2$/day of the direct normal insolation was evaluated for clear days.

  • PDF