• Title/Summary/Keyword: damaged reinforced concrete

Search Result 321, Processing Time 0.03 seconds

Seismic performance evaluation of fiber-reinforced prestressed concrete containments subject to earthquake ground motions

  • Xiaolan Pan;Ye Sun;Zhi Zheng;Yuchen Zhai;Lianpeng Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1638-1653
    • /
    • 2024
  • Given the unpredictability of the occurrence of the earthquake and other potential disasters into consideration, the nuclear power plant may be confronted with beyond design-basis earthquake load in the future. The containment structure may be severely damaged under such severe earthquake loading, increasing the risk of containment concrete cracking and potential radioactive materials leaking. Moreover, initial damage caused by the earthquake may significantly alter the pressure performance of the containment under follow-up internal pressure. To compromise the dangers of beyond design-basis earthquake to the containment, an alternative of replacing the conventional concrete with fiber-reinforced concrete (FRC) to upgrade the seismic resistance capacity of the containment is attempted and thoroughly researched. In this study, the influence of various fiber types such as rigid fiber and mixed fiber is regarded to constitute fiber-reinforced PCCVs. The physical properties of traditional and fiber-reinforced PCCVs under earthquake ground motions are scientifically compared and identified by using traditional and proposed evaluation indices. The results indicate that both the traditional evaluation index (i.e. top displacement, stress, strain) and the proposed damage index are greatly reduced by the practice of fiber strengthening under earthquake ground motions.

Seismic risk priority classification of reinforced concrete buildings based on a predictive model

  • Isil Sanri Karapinar;Ayse E. Ozsoy Ozbay;Emin Ciftci
    • Structural Engineering and Mechanics
    • /
    • v.91 no.3
    • /
    • pp.279-289
    • /
    • 2024
  • The purpose of this study is to represent a useful alternative for the preliminary seismic vulnerability assessment of existing reinforced concrete buildings by introducing a statistical approach employing the binary logistic regression technique. Two different predictive statistical models, namely full and reduced models, were generated utilizing building characteristics obtained from the damage database compiled after 1999 Düzce earthquake. Among the inspected building parameters, number of stories, overhang ratio, priority index, soft story index, normalized redundancy ratio and normalized lateral stiffness index were specifically selected as the predictor variables for vulnerability classification. As a result, normalized redundancy ratio and soft story index were identified as the most significant predictors affecting seismic vulnerability in terms of life safety performance level. In conclusion, it is revealed that both models are capable of classifying the set of buildings being severely damaged or collapsed with a balanced accuracy of 73%, hence, both are able to filter out high-priority buildings for life safety performance assessment. Thus, in this study, having the same high accuracy as the full model, the reduced model using fewer predictors is proposed as a simple and viable classifier for determining life safety levels of reinforced concrete buildings in the preliminary seismic risk assessment.

Modelling the reinforced concrete beams strengthened with GFRP against shear crack

  • Kaya, Mustafa;Yaman, Canberk
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.127-137
    • /
    • 2018
  • In this study, the behavior of the number of anchorage bolts on the glass-fiber reinforced polymer (GFRP) plates adhered to the surfaces of reinforcing concrete (RC) T-beams was investigated analytically. The analytical results were compared to the test results in term of shear strength, and midpoint displacement of the beam. The modelling of the beams was conducted in ABAQUS/CAE finite element software. The Concrete Damaged Plasticity (CDP) model was used for concrete material modeling, and Classical Metal Plasticity (CMP) model was used for reinforcement material modelling. Model-1 was the reference specimen with enough sufficient shear reinforcement, and Model-2 was the reference specimen having low shear reinforcement. Model-3, Model-4 and Model-5 were the specimens with lower shear reinforcement. These models consist of a single variable which was the number of anchorage bolts implemented to the GFRP plates. The anchorage bolts of 2, 3, and 4 were mutually mounted on each GFRP plates through the beam surfaces for Model-3, Model-4, and Model-5, respectively. It was found that Model-1, Model-3, Model-4 and Model-5 provided results approximately equal to the test results. The results show that the shear strength of the beams increased with increasing of anchorage numbers. While close results were obtained for Model-1, Model-3, Model-4 and Model-5, in Model-2, the rate of increase of displacement was higher than the increase of load rate. It was seen, finite element based ABAQUS program is inadequate in the modeling of the reinforced concrete specimens under shear force.

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.

Stfuctural Behavior of Cracked Reinforced Concrete Beams Strengthened by Epoxy Bonded Steel Plates(EBSP) (에폭시 접착강판으로 보강된 철근콘크리트보의 구조적 거동에 관한 연구)

  • 김유식;류해준;최완철;홍기섭;신영수;홍영균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.25-29
    • /
    • 1994
  • A series of 6 reinforced concrete beams was tested to verify the effects of EBSP strengthened on cracked beams and to identify the various parameters affecting structure strengthening design(SSD). The parameters were the cross-sectional area of steel plates, the thickness of steel plates, and bond length of steel plates. In addition to these parameters, the effect of existing cracks on the strengthening was investigated. Test results show that EBSP is very effective and predictable for strengthening damaged structures. The results also show that the bond length of steel plates is the most important factor to develop ultimate load carrying capacities of strengthened beams. However, considerations in SSD should be given to assure the ductile failure at ultimate load such as the low ratio of thickness to the width of plates.

  • PDF

Evaluation of Post-earthquake Seismic Capacity of Reinforced Concrete Buildings suffering from earthquakes (지진피해를 받은 철근콘크리트 건물의 잔존내진성능평가)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.105-108
    • /
    • 2005
  • In damage investigation of building structures suffering from earthquake, estimation of residual seismic capacity is essential in order to access the safety of the building against aftershocks and to judge the necessity of repair and restoration. It has been proposed that an evaluation method for post-earthquake seismic capacity of reinforced concrete buildings based. on the residual energy dissipation capacity (the residual seismic capacity ratio )in lateral force-displacement curve of structural members. The proposed method was adopted in the Japanese 'Damage Level Classification Standard' revised in 200l. To evaluate the residual seismic capacity of RC column, experimental tests with positive and negative cyclic loading was carried out using RC building column specimen. Parameters used by the experiment are deformability and member proportion. From the test results, it is appropriated that the residual seismic capacity of RC buildings damaged by earthquakes is evaluated using the method in the Guideline.

  • PDF

Parametric Analysis of High-Strength Reinforced Concrete Beams at High Temperature

  • Choi Eun Gyu;Kang Ji Yeon;Shin Mi Kyung;Shin Yeong Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.585-590
    • /
    • 2004
  • An analytical method is proposed for the analysis of the reinforced concrete flexural beam subjected to high temperature. The analysis procedure for the material properties, in this study, is subdivided into two types; thermal properties for temperature distribution analysis and mechanical properties for structural analysis. Using F.D.M. and segmentation method, the program was made to predict the thermal behavior of RC beams during heating. In previous studies, the structural behavior of fire damaged RC beams was investigated though experiments. Comparing the result by program to the one by experiment, the comparison indicated that the proposed segmentation method for the thermal respose analysis present fairly a good agreement with experiment.

  • PDF

Dynamic behavior investigation of scale building renovated by repair mortar

  • Basaran, Hakan
    • Computers and Concrete
    • /
    • v.16 no.4
    • /
    • pp.531-544
    • /
    • 2015
  • The objective of this study was to examine the effect of repair mortar on the dynamic properties such as natural frequencies, mode shape and damping ratios of two story single span scale reinforced concrete building. To this end, two story single span scale reinforced concrete building having dimensions of 150 cm (width), 150 cm (length) and 135 cm (height) was constructed. Workmanship defects such as separation of material, faulty vibration application and bad gradation of the structure were properly evaluated. Dynamic properties of damaged structure were experimentally determined using Operational Modal Analysis (OMA). Detected defects in the structure were fixed by plastering with repair mortar. Dynamic properties of repaired structure were reevaluated by using the OMA method. Finite element software called Abaqus was used to numerically determine dynamic properties of the structure. Structure modeled as solid was subjected to Linear Perturbation Frequency Method. The changes in dynamic properties of structure after the repair process were comparatively studied by evaluating experimental and numerical results.

Development of the Repair and Rehabilitation Methods for R/C Structures (철근콘크리트 구조물의 보수 보강 신기술 개발)

  • Sim, Jong-Sung;Hong, Young-Kyun;Choi, Long;Im, Chang-Duck
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.207-211
    • /
    • 1995
  • As the construction industry has been developed since 1970, there is a great needs to develop the methodology for repair and rehabilitation of the damaged reinforced concrete structures. Numerous materials which are currently used in construction field without any regulations are examined in terms of their serviceabilities and effectiveness. Structural behavior of repaired beams are investigated both statically and dynamically. This paper summarize the overall research plan, which is sponsored by KICT, in 1994.

  • PDF

An Experimental Study on Shear-Strengthening Effect of Reinforced Concrete Beams by Steel Plates and GFS (강판 및 유리섬유쉬트로 보강된 철근콘크리트 보의 전단보강 효과에 관한 실험 연구)

  • 최현구;오성영;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.739-744
    • /
    • 2000
  • The aim of this research is to investigate and to compare the shear strengthening effects of steel plates and glass fiber sheets(GFS). Shear damaged beams were repaired by steel plates and GFS. Thickness of steel plates and strengthening type of GFS were taken as the parameters. With loading, the development and propagation of cracks, failure mode and deformation of strengthening materials were checked. The ultimate load was compared with formulas proposed by previous researchers.

  • PDF