• Title/Summary/Keyword: damage condition

Search Result 2,010, Processing Time 0.027 seconds

Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.463-477
    • /
    • 2022
  • In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

ANN-Based Real-Time Damage Detection Technique Using Acceleration Signals in Beam-Type Structures (보 구조물의 가속도 신호를 이용한 인공신경망 기반 실시간 손상검색기법)

  • Park, Jae-Hyung;Lee, Yong-Hwan;Kim, Jeong-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.229-237
    • /
    • 2007
  • In this study, an artificial neural network (ANN)-based damage detection algorithm using acceleration signals is developed for real-time alarming locations of damage in beam-type structures. A new ANN-algorithm using output-only acceleration responses is designed tot damage detection in real time. The cross-covariance of two acceleration-signals measured at two different locations is selected as the feature representing the structural condition. Neural networks are trained lot potential loading Patterns and damage scenarios of the target structure for which its actual loadings are unknown. The feasibility and practicality of the proposed method are evaluated from laboratory-model tests on free-free beams for which accelerations were measured before and after several damage cases.

Study on the Characteristics of Cavitation Erosion-Corrosion for Mild Steel ( 1 ) - Damage Behaviour of Vibration Cavitation Erosion-Corrosion - (연강의 캐비테이션 침식-부식 특성에 관한 연구 ( 1 ) - 진동 캐비네이션 침식-부식 손상 거동 -)

  • Lim, Un-Joh;Hwang, Jae-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.413-422
    • /
    • 1995
  • Cavitation erosion-corrosion implies damage to materials due to the shock pressure or shock wave that results when bubbles form and collapse at a metal surface within a liquid. If the liquid is corrosive to the material, a condition typically encountered in industry, the component materials may suffer serious damage by a combination of mechanical and electrochemical attack. In this study, the mild steel(SS41) was tested by using the piezoelectric vibrator with 20kHz, 24$\mu$m to cavity generation apparatus. The damage behaviour of vibration cavitation erosion-corrosion and the environment characteristics were investigated in various solutions which are seawater, tap water and distilled water. The main results obtained are as follows; 1) The cavitation erosion-corrosion damage behaviour in the seawater increases to occur at the equal degree on the middle portion and the outside portion of specimen. The distilled water specimen, on other hand, occurs beginning on the outside portion across to the middle portion of specimen. 2) The cavitation erosion-corrosion damage in the tap water of low specific resistance more increases than that in the distilled water of high specific resistance at the initial testing time and more decreases than that in it by the CaCO sub(3) film with testing time. 3) Cavitation erosion-corrosion damage characteristic divides into four regions; incubation region, acceleration region, deceleration region and steady state region.

  • PDF

The optimal model of reperfusion injury in vitro using H9c2 transformed cardiac myoblasts

  • Son, Euncheol;Lee, Dongju;Woo, Chul-Woong;Kim, Young-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.24 no.2
    • /
    • pp.173-183
    • /
    • 2020
  • An in vitro model for ischemia/reperfusion injury has not been well-established. We hypothesized that this failure may be caused by serum deprivation, the use of glutamine-containing media, and absence of acidosis. Cell viability of H9c2 cells was significantly decreased by serum deprivation. In this condition, reperfusion damage was not observed even after simulating severe ischemia. However, when cells were cultured under 10% dialyzed FBS, cell viability was less affected compared to cells cultured under serum deprivation and reperfusion damage was observed after hypoxia for 24 h. Reperfusion damage after glucose or glutamine deprivation under hypoxia was not significantly different from that after hypoxia only. However, with both glucose and glutamine deprivation, reperfusion damage was significantly increased. After hypoxia with lactic acidosis, reperfusion damage was comparable with that after hypoxia with glucose and glutamine deprivation. Although high-passage H9c2 cells were more resistant to reperfusion damage than low-passage cells, reperfusion damage was observed especially after hypoxia and acidosis with glucose and glutamine deprivation. Cell death induced by reperfusion after hypoxia with acidosis was not prevented by apoptosis, autophagy, or necroptosis inhibitors, but significantly decreased by ferrostatin-1, a ferroptosis inhibitor, and deferoxamine, an iron chelator. These data suggested that in our SIR model, cell death due to reperfusion injury is likely to occur via ferroptosis, which is related with ischemia/reperfusion-induced cell death in vivo. In conclusion, we established an optimal reperfusion injury model, in which ferroptotic cell death occurred by hypoxia and acidosis with or without glucose/glutamine deprivation under 10% dialyzed FBS.

DNA Damage of Lymphocytes in Volunteers after 4 hours Use of Mobile Phone (일부 자원자들의 이동전화 4시간 연속 사용 후 림프구 DNA 손상 평가)

  • Ji, Seon-Mi;Oh, Eun-Ha;Sul, Dong-Geun;Choi, Jae-Wook;Park, Hee-Chan;Lee, Eun-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.373-380
    • /
    • 2004
  • Objectives : There has been gradually increasing concern about the adverse health effects of electromagnetic radiation originating from cell phones which are widely used in modern life. Cell phone radiation may affect human health by increasing free radicals of human blood cells. This study has been designed to identify DNA damage of blood cells by electromagnetic radiation caused by cell phone use. Methods : This study investigated the health effect of acute exposure to commercially available cell phones on certain parameters such as an indicator of DNA damage for 14 healthy adult volunteers. Each volunteer during the experiment talked over the cell phone with the keypad facing the right side of the face for 4 hours. The single cell gel electrophoresis assay (Comet assay), which is very sensitive in detecting the presence of DNA strand-breaks and alkali-labile damage in individual cells, was used to assess peripheral blood cells (T-cells, B-cells, granulocytes) from volunteers before and after exposure to cell phone radiation. The parameters of Comet assay measured were Olive Tail Moment and Tail DNA %. Results : The Olive Tail Moment of B-cells and granulocytes and Tail DNA % of B-cells and granulocytes were increased by a statistically significant extent after 4-hour use of a cell phone compared with controls. Conclusion : It is concluded that cell phone radiation caused the DNA damage during the 4 hours of experimental condition. Nonetheless, this study suggested that cell phone use may increase DNA damage by electromagnetic radiation and other contributing factors.

Structural Health Monitoring of Full-Scale Concrete Girder Bridge Using Acceleration Response (가속도 응답을 이용한 실물 콘크리트 거더 교량의 구조건전성 모니터링)

  • Hong, Dong-Soo;Kim, Jeong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.165-174
    • /
    • 2010
  • In this paper, a two-phase structural health monitoring system using acceleration response signatures are presented to firstly alarm the change in structural condition and to secondly detect the changed location for full-scale concrete girder bridges. Firstly, Mihocheon Bridge which is a two-span continuous concrete girder bridge is selected as the target structure. The dynamic response features of Mihocheon Bridge are extracted by forced vibration test using bowling ball. Secondly, the damage alarming occurrence and the damage localization techniques are selected to design two-phase structural health monitoring system for Mihocheon Bridge. As the damage alarming techniques, auto-regressive model using time-domain signatures, correlation coefficient of frequency response function and frequency response ratio assurance criterion are selected. As the damage localization technique, modal strain energy-based damage index method is selected. Finally, the feasibility of two-phase structural health monitoring systems is evaluated from static loading tests using a dump truck.

Study on Investigation and Analysis about Damage of Tunnels (국내외 터널구조물의 변상에 관한 조사 및 분석)

  • Bae, Gyu-Jin;Lee, Sung-Won;Cho, Mahn-Sup;Lee, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.3
    • /
    • pp.31-43
    • /
    • 2001
  • In this study, we carried out investigation and analysis on damages in tunnels on order to provide the basic information for the safety assessment of tunnels and to minimize the potential damage of the same kind as investigated. The frequencies of occurrence in terms of 4 items, i.e., service life interval, type of the damage, cause of the damage, and geological condition, were examined and summarized based on 44 foreign and domestic cases of tunnel damages. Also, we carried out a survey research of which the content included 28 questions on the tunnel safety assessment. The answers collected from domestic experts in tunneling suggested that the most probable cause of the tunnel damages was cracking in tunnels at 42~58%. They also suggested that the poor constrution work strongly caused the damages. Therefore, to ensure tunnel safety, high quality of constrution should be maintained as examined. The types of damage and their extent of influence on the overall tunnel safety are of practical importance to be used in the artficial intelligent system for tunnel safety assessment.

  • PDF

On-Site Conservation of the Underwater Objects Excavated (해저 발굴유물의 현장 보존처리)

  • Moon, Whan-Suk;Kim, Byung-Keun;Yang, Soon-Seok
    • 보존과학연구
    • /
    • s.25
    • /
    • pp.133-150
    • /
    • 2004
  • Once the object has been excavated at underwater condition, it should be subjected to condition that may cause its deterioration. Therefore, it is important that the object immediately keeps stable environment. It means that the object was excavated at underwater and it exposed the deterioration condition, as soon as possible it was not dried on surface, especially metallic and organic material. Iron objects is particularly notorious for rapid disintegration that it kept wet or stored in a stable environment. Ceramics, glass and stone were handled carefully that it prevented physical damage by mishandling. Organic materials of wood, leather, rope, bone must not be allowed to dry out because the creaking, shrinking and warping are well known disintegration. Therefore objects is basis of keeping stable condition in on-site and then it will have to pass through a detailed conservation process in the laboratory.

  • PDF

A Study on the Optimum Image Capture of Wear Particle for Condition Monitoring of Machine (기계의 상태 모니터링을 위한 최적의 마멸분 영상 획득 방법에 관한 연구)

  • Cho, Yon-Sang;Park, Heung-Sik
    • Tribology and Lubricants
    • /
    • v.23 no.6
    • /
    • pp.301-305
    • /
    • 2007
  • The wear particle analysis has been known as very effective method to foreknow and decide a moving situation and a damage of machine parts by using the digital computer image processing. But it was not laid down and trusted to calculate shape parameters of wear particle and wear volume. In order to apply image processing method in the foreknowledge and decision of lubricated condition, it needs to verify the reliability of the calculated data by the image processing and to lay down the number of images and the amount of wear particle in one image. In this study, the lubricated friction experiment was carried out in order to establish the optimum image capture with the SM45C specimen under experiment condition. The wear particle data were calculated differently according to the number of image and the amount of wear particle in one image.

Superconducting high gradient magnetic separation for magnetic substance at sludge powder of hot rolled coolant

  • Kwon, Jun-Mo;Ha, Dong-Woo;Kim, Tae-Hyung;Cho, Mun-Dak;Choi, Woo-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.353-353
    • /
    • 2009
  • It is an important task to construct a recycling society with a low damage on the environment in our century. Magnetic separation is expected to be applied for the industrial waste treatment as an important supporting technology. In the magnetic separation of dry condition, the cohesive force between particles is strong compared with that in the wet condition's magnetic separation. The use of high magnetic field by the superconducting magnet enhances the powder's magnetic substance capture ability of the magnetic separation. In this study, the POSCO's coolant sludge of hot rolled steel was used for the superconducting magnetic separation of dry condition. Cryo-cooled NB-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF