• Title/Summary/Keyword: d-q transform

Search Result 33, Processing Time 0.022 seconds

Lip Contour Detection by Multi-Threshold (다중 문턱치를 이용한 입술 윤곽 검출 방법)

  • Kim, Jeong Yeop
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.12
    • /
    • pp.431-438
    • /
    • 2020
  • In this paper, the method to extract lip contour by multiple threshold is proposed. Spyridonos et. el. proposed a method to extract lip contour. First step is get Q image from transform of RGB into YIQ. Second step is to find lip corner points by change point detection and split Q image into upper and lower part by corner points. The candidate lip contour can be obtained by apply threshold to Q image. From the candidate contour, feature variance is calculated and the contour with maximum variance is adopted as final contour. The feature variance 'D' is based on the absolute difference near the contour points. The conventional method has 3 problems. The first one is related to lip corner point. Calculation of variance depends on much skin pixels and therefore the accuracy decreases and have effect on the split for Q image. Second, there is no analysis for color systems except YIQ. YIQ is a good however, other color systems such as HVS, CIELUV, YCrCb would be considered. Final problem is related to selection of optimal contour. In selection process, they used maximum of average feature variance for the pixels near the contour points. The maximum of variance causes reduction of extracted contour compared to ground contours. To solve the first problem, the proposed method excludes some of skin pixels and got 30% performance increase. For the second problem, HSV, CIELUV, YCrCb coordinate systems are tested and found there is no relation between the conventional method and dependency to color systems. For the final problem, maximum of total sum for the feature variance is adopted rather than the maximum of average feature variance and got 46% performance increase. By combine all the solutions, the proposed method gives 2 times in accuracy and stability than conventional method.

Ecological Characteristic of Warm Temperate Vegetation Distributed around Hakdong and Haegeumgang at Geojae Island (거제도 학동 및 해금강 일대에 분포하는 난대림 식생의 생태적 특성 연구)

  • Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.1
    • /
    • pp.72-86
    • /
    • 2022
  • This study was conducted to identify structural characteristics of the evergreen broad-leaved forests distributed in Hak-dong, Geojae island. For a survey, 52 sites were set up in areas with changes in the vegetation community or location environment where Cinnamomum yabunikkei, Neolitsea sericea, and Machilus thunbergii dominated or appeared in the canopy, sub-canopy, or shrub layer. The community classification with TWINSPAN identified the following communities: N. sericea-C. yabunikkei, C. yabunikkei-Camellia japonica, Ca. japonica, Quercus variabilis-Ca. japonica, Pinus thunbergii-Ca. japonica, Castanopsis sieboldii, P. thunbergii, and Platycarya strobilacea-Mallotus japonicus. Considering the result of the study that succession series of warm-temperate forest reflecting the latent natural vegetation is the transition of conifers and deciduous broad-leaved forest to evergreen broad-leaved forest, the communities predominated by the communities predominated by the communities predominated by P. thunbergii, Q. variabilis, and Pl. strobilacea are likely to transform into the evergreen forest predominated by N. sericea and C. yabunikkei. The sites where C. yabunikkei, N. sericea, and Castanopsis sieboldii are dominant in the canopy and sub-canopy layers are likely to maintain the status quo if there is no artificial disturbance. The relationship between the impact of the environmental factors and the vegetation distribution showed silt among the physical properties of the soil directly or indirectly affected it, which was judged to be due to the fact that it was located on a steep slope. The soil acidity (pH) was 5-5.84, electrical conductivity 0.047-0.139 dS/m, and organic matter content was 3.32-12.06%. Although there were differences by the colony, they were generally low.

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.