• Title/Summary/Keyword: d-q method

Search Result 561, Processing Time 0.028 seconds

Single-Balanced Low IF Resistive FET Mixer for the DBF Receiver

  • Ko Jee-Won;Min Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.4
    • /
    • pp.143-149
    • /
    • 2004
  • This paper describes characteristics of the single-balanced low IF resistive FET mixer for the digital beam forming(DBF) receiver. This DBF receiver based on the direct conversion method is designed with Low IF I and Q channel. A radio frequency(RF), a local oscillator(LO) and an intermediate frequency(IF) considered in this research are 1950 MHz, 1940 MHz and 10 MHz, respectively. Super low noise HJ FET of NE3210S01 is considered in design. The measured results of the proposed mixer are observed IF output power of -22.8 dBm without spurious signal at 10 MHz, conversion loss of -12.8 dB, isolation characteristics of -20 dB below, 1 dB gain compression point(PldB) of -3.9 dBm, input third order intercept point(IIP3) of 20 dBm, output third order intercept point(OIP3) of 4 dBm and dynamic range of 30 dBm. The proposed mixer has 1.0 dB higher IIP3 than previously published single-balanced resistive and GaAs FET mixers, and has 3.0 dB higher IIP3 and 4.3 dB higher PldB than CMOS mixers. This mixer was fabricated on 0.7874 mm thick microstrip $substrate(\varepsilon_r=2.5)$ and the total size is $123.1\;mm\times107.6\;mm$.

Implementation of Multi-Motor Controller Based on a Single Microcontroller (단일 마이크로컨트롤러 기반 다중 모터제어기 구현)

  • Kwon, Jae-Min;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.237-243
    • /
    • 2015
  • In this paper, we consider a cascaded type of control architecture for a multi motor-based feedback control system and propose an ADC (Analog to Digital Converter) resource allocation method to efficiently utilize the limited ADC resources. The purpose of the resource allocation method is to minimize both the motor position measurement error and the d-q current measurement error. The cascaded type of control architecture is applied in parallel to each motor to independently control the speed of a motor in the multi motor control system. All the control algorithms are implemented by software using a single microcontroller without using additional microcontrollers. It is illustrated by experiments that the speed and the torque of each motor are controlled precisely by the proposed control architecture with the efficient ADC allocation method.

Dielectric and piezoelectric properties of 0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 lead-free ceramics (0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 무연 세라믹스의 유전 및 압전 특성)

  • Kim, Mi-Ro;Yoon, Seok-Jin;Choi, Ji-Won
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.155-159
    • /
    • 2010
  • 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ lead free piezoelectric ceramics were synthesized to enhance the piezoelectric properties of (Na,K)$NbO_3$. The systhesis and sintering method were the conventional solid state reaction method and general sintering method in air atmosphere. The polymorphic phase transition(PPT) was observed at all composition(0 $\leq$ x $\leq$ 0.05) when $(Ba_{(1-x)}Sr_x)TiO_3$ were added in the $(Na_{0.5}K_{0.5})NbO_3$. As Sr concentration was increased, grain size, dielectric loss(tan$\delta$) and mechanical quality factor($Q_m$) were decreased and piezoelectric constant($d_{33}$) and electromechanical coupling factor($k_p$) were increased within a limited value. The optimized piezoelectric and properties, $d_{33}$, $k_p$, $Q_m$, and tand, of 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ were 139 pC/N, 0.31 %, 95, 0.04 at the composition of x=0.04.

Dead Time Compensation Algorithm for the 3-Phase Inverter using SVPWM (SVPWM 방식의 3상 인버터에 대한 간단한 데드타임 보상 알고리즘)

  • Kim, Hong-Min;Choo, Young-Bae;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.610-617
    • /
    • 2011
  • This paper proposes a novel and direct dead-time compensation method of the 3-phase inverter using space vector pulse width modulation(SVPWM) topology. The proposed dead-time compensation method directly compensates the dead-time to the turn-on time of the effective voltage vector according to the current direction of the medium voltage reference. Each phase voltages are determined by the switching times of the effective voltage vectors, and the practical switching times have loss according to the current direction by the dead-time effect in the 3-phase inverter. The proposed method adds the dead-time to the switching time of the effective voltage vector according to the current direction, so it does not require complex d-q transform and controller to compensate the voltage error. The proposed dead-time compensation scheme is verified by the computer simulation and experiments of 3-phase R-L load.

Three-Phase Z-Source Dynamic Voltage Restorer with a Fuel Cells Source (연료전지 전원을 갖는 3상 Z-소스 동적 전압 보상기)

  • Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.41-48
    • /
    • 2008
  • This paper proposes a three-phase Z-source dynamic voltage restorer (Z-DVR) to mitigate the voltage sag for the critical loads. The proposed system is composed of passive filter and Z-source topology inverter. As an ESS(Energy Storage System) of the proposed system is employed the Proton Exchange Membrane Fuel Cells (PEMFC). To calculate and control the harmonics and compensation voltage, $i_{d}-i_{q}$ theory in dq rotating reference frame and PI controller are used. In case that three-phase voltage sags occurred, a PSIM simulation was done for the performance comparison of the conventional method employed battery stacks and proposed method. As a result, considering the voltage compensation performance, each method was nearly similar. Also, the compensation performance and the %THD(%Total Harmonic Distortion) result under the various source voltage conditions (sag or swell) were presented and discussed to show the performance of the proposed system.

A Study on the Integrated Computer Program for the Multi Analysis of In-Situ Aquifer and Geothermal Response Test (현장 열응답시험과 현장 대수성시험결과를 동시 분석 가능한 통합전산 Program에 관한 연구)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Yonn, Yun-Sang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 2008
  • Groundwater flow in confined aquifer and heat transport in underground geologic media are using same governing equation(line source) like well fuction. Therefore the conventional slope method using only later data obtained from in-situ thermal response test to determine the thermal conductivity of vertical geothermal heat exchanger(GHEX) is basically identical with one of Theis straight line method of aquifer test under artesian condition. In case that the pumping rate(Q, $m^3$/d) and drawdown(s,m) which are used for input data of existing hydrogeologic computer programs for aquifer test are replaced and converted to supplying heat energy per unit length of bore hole(Q/L,w/m or Kcal/h.m) and temperatures (T,$^{\circ}C$)measured at in and out-let of GHEX as in put data respectively, thermal conductivity around geothermal heat exchanger can be easily estimated without any special modification of the existing hydrogeologic computer program. Two numbers of time series temperature variation data obtained from in situ geothermal response test are analized using Theismethods(standard curve and straight line method) by using existing aquifer test program and conventional Slope method proposed by ASHRAE. The results show that thermal conductivity values estimated by two straight methods are identical and the difference of estimated values between standard curve methods and Slope method are also within acceptable ranges. In general,the thermal conductivity estimated from Theis straight linemethod gives more accurate value than the one of Slope method due to that Slope method uses only visual matching otherwise Theis method uses automatic curve matching estimation with reducing RSS.

  • PDF

Evidence of Spin Reorientation by Mössbauer Analysis

  • Myoung, Bo Ra;Kim, Sam Jin;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.126-129
    • /
    • 2014
  • We report the crystallographic and magnetic properties of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ by means of X-ray diffractometer (XRD), a superconducting quantum interference device (SQUID) magnetometer, and a M$\ddot{o}$ssbauer spectroscopy. In particular, $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was studied by M$\ddot{o}$ssbauer analysis for evidence of spin reorientation. The chalcogenide material $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was fabricated by a direct reaction method. XRD analysis confirmed that $Ni_{0.3}Fe_{0.7}Ga_2S_4$ has a 2-dimension (2-D) triangular lattice structure, with space group P-3m1. The M$\ddot{o}$ssbauer spectra of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ at spectra at various temperatures from 4.2 to 300 K showed that the spectrum at 4.2 K has a severely distorted 8-line shape, as spin liquid. Electric quadrupole splitting, $E_Q$ has anomalous two-points of temperature dependence of $E_Q$ curve as freezing temperature, $T_f=11K$, and N$\acute{e}$el temperature, $T_N=26K$. This suggests that there appears to be a slowly-fluctuating "spin gel" state between $T_f$ and $T_N$, caused by non-paramagnetic spin state below $T_N$. This comes from charge re-distribution due to spin-orientation above $T_f$, and $T_N$, due to the changing $E_Q$ at various temperatures. Isomer shift value ($0.7mm/s{\leq}{\delta}{\leq}0.9mm/s$) shows that the charge states are ferrous ($Fe^{2+}$), for all temperature range. The Debye temperature for the octahedral site was found to be ${\Theta}_D=260K$.

Design and Implementation of Photovoltaic Power Conditioning System using a Current-based Maximum Power Point Tracking

  • Lee, Sang-Hoey;Kim, Jae-Eon;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.606-613
    • /
    • 2010
  • This paper proposes a novel current-based maximum power point tracking (CMPPT) method for a single-phase photovoltaic power conditioning system (PV PCS) by using a modified incremental conductance method. The CMPPT method simplifies the entire control structure of the power conditioning system and uses an inherent current source characteristic of solar cell arrays. Therefore, it exhibits robust and fast response under a rapidly changing environmental condition. Digital phase locked loop technique using an all-pass filter is also introduced to detect the phase of grid voltage, as well as the peak voltage. Controllers of dc/dc boost converter, dc-link voltage, and dc/ac inverter are designed for coordinated operation. Furthermore, a current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. A 3 kW prototype PV PCS is built, and its experimental results are given to verify the effectiveness of the proposed control schemes.

3차원적 도핑 분포 측정을 위한 SCM 응용 방법 (The SCM Method for Three-Dimensional Dopant Profiles)

  • Lee Jun-Ha;Lee Hoong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • Through SCM modeling, we found that the depletion layer in silicon was of a form of a spherical capacitor with the SCM tip biased. Two-dimensional (2D) finite differential method code with a successive over relaxation (SOR) solver has been developed to model the measurements by SCM of a semiconductor wafer that contains an ion-implanted impurity region. Then, we theoretically analyzed the spherical capacitor and determined the total depleted-volume charge Q, capacitance C, and the rate of capacitance change with bias dC/dV. It is very important to observe the depleted carriers' movement in the silicon layer by applying the bias to the tip. So, we calculated the depleted-volume charge, considering different factors such as tip size, oxide thickness, and applied bias (dc+ac), which have an influence on potential and depletion charges.

  • PDF

Analysis on Spectral Regrowth of Bandwidth Expansion Module by Quadrature Modulation Error in Digital Chirp Generator (디지털 첩 발생기에서의 직교 변조 오차에 의한 대역 확장 모듈에서의 스펙트럴 재성장 분석)

  • Kim, Se-Young;Sung, Jin-Bong;Lee, Jong-Hwan;Yi, Dong-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.761-768
    • /
    • 2010
  • This paper presents an effective method to achieve the wideband waveform for high resolution SAR(Synthetic Aperture Radar) using the frequency multiplication technique. And also this paper analyzes the root causes for the spectral regrowth due to 3rd-order intermodulation in chirp bandwidth expansion scheme using quadrature modulator and frequency multipliers. The amplitude and phase imbalance requirement are defined based on the simulation results in terms of quadrature channel imbalance. This minimizes the degradation of range resolution, peak sidelobe ratio and integrated sidelobe ratio. The wideband chirp generator using the frequency multiplier and memory map scheme was manufactured and the compensation technique was presented to reduce the spectral regrowth of SAR waveform by minimizing the amplitude and phase imbalance. After I and Q channel imbalance adjustment, the carrier level reduces -28.7 dBm to -53.4 dBm. Chirp signal with 150 MHz bandwidth at S-band expands to 600 MHz bandwidth at X-band. The sidelobe levels are reduced by about 8 to 9 dB by compensating the amplitude balance between I and Q channels.