• 제목/요약/키워드: cylinders

검색결과 1,174건 처리시간 0.032초

Splitting of Surface Plasmon Resonance Peaks Under TE- and TM-polarized Illumination

  • Yoon, Su-Jin;Hwang, Jeongwoo;Lee, Myeong-Ju;Kang, Sang-Woo;Kim, Jong-Su;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.296-296
    • /
    • 2014
  • We investigate experimentally and theoretically the splitting of surface plasmon (SP) resonance peaks under TE- and TM-polarized illumination. The SP structure at infrared wavelength is fabricated with a 2-dimensional square periodic array of circular holes penetrating through Au (gold) film. In brief, the processing steps to fabricate the SP structure are as follows. (i) A standard optical lithography was performed to produce to a periodic array of photoresist (PR) circular cylinders. (ii) After the PR pattern, e-beam evaporation was used to deposit a 50-nm thick layer of Au. (iii) A lift-off processing with acetone to remove the PR layer, leading to final structure (pitch, $p=2.2{\mu}m$; aperture size, $d=1.1{\mu}m$) as shown in Fig. 1(a). The transmission is measured using a Nicolet Fourier-transform infrared spectroscopy (FTIR) at the incident angle from $0^{\circ}$ to $36^{\circ}$ with a step of $4^{\circ}$ both in TE and TM polarization. Measured first and second order SP resonances at interface between Au and GaAs exhibit the splitting into two branches under TM-polarized light as shown in Fig. 1(b). However, as the incidence angle under TE polarization is increased, the $1^{st}$ order SP resonance peak blue-shifts slightly while the splitting of $2^{nd}$ order SP resonance peak tends to be larger (not shown here). For the purpose of understanding our experimental results qualitatively, SP resonance peak wavelengths can be calculated from momentum matching condition (black circle depicted in Fig. 2(b)), $k_{sp}=k_{\parallel}{\pm}iG_x{\pm}jG_y$, where $k_{sp}$ is the SP wavevector, $k_{\parallel}$ is the in-plane component of incident light wavevector, i and j are SP coupling order, and G is the grating momentum wavevector. Moreover, for better understanding we performed 3D full field electromagnetic simulations of SP structure using a finite integration technique (CST Microwave Studio). Fig. 1(b) shows an excellent agreement between the experimental, calculated and CST-simulated splitting of SP resonance peaks with various incidence angles under TM-polarized illumination (TE results are not shown here). The simulated z-component electric field (Ez) distribution at incident angle, $4^{\circ}$ and $16^{\circ}$ under TM polarization and at the corresponding SP resonance wavelength is shown in Fig. 1(c). The analysis and comparison of theoretical results with experiment indicates a good agreement of the splitting behavior of the surface plasmon resonance modes at oblique incidence both in TE and TM polarization.

  • PDF

이장재의 세포독성에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CYTOTOXICITY OF CAVITY LINERS)

  • 김정혜;김영해
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.77-92
    • /
    • 1990
  • The purpose of this study was to evaluate the cytotoxic effects of 6 cavity liners in vitro. Human fibroblasts were cultured in ${\alpha}$-MEM and each liner was manually mixed and filled in glass ring cylinder ($8{\times}8mm$ in diameter, in height). The cylinders filled with the liners were placed in the center of the dish (35mm in diameter) containing 3ml of ${\alpha}$-MEM. Millipore filters (pore size $0.22{\mu}m$) to simulate dentin barrier were also placed between the bottom of cylinder and the dish. Then the culture dishes were stored in 5% $CO_2$ containing incubator for 5 and 10 days at the temperature of $36.6^{\circ}C$. The results of the experiments were analyzed by counting the cells in the period of 5 and 10 days respectively, and were assessed by calculating the cell multiplication rate and the relative growth rate. The experiemntal groups and the control group were compared statistically. The results of the study were summarized as follows: 1. The cell number of Zinc oxide-eugenol was $(4.13{\pm}1.31){\times}10^4$ cells/ml at 5 days and $(4.32{\pm}1.61){\times}10^4$ cells/ml at 10 days. 2. The cell number of Cavitec was ($8.35{\pm}2.87{\times}10^4$ cells/ml and $(10.08{\pm}5.10){\times}10^4$ cells/ml at 5 and 10 days respectively. 3. The cell number of Dycal was $(13.56{\pm}3.89){\times}10^4$ cells/ml at 5 days and $(34.75{\pm}8.85){\times}10^4$ cells/ml at 10 days. 4. The cell number of life was $(11.46{\pm}3.32){\times}10^4$ cells/ml and $(21.92{\pm}6.18){\times}10^4$ cells/ml at 5 and 10 days. 5. The cell number of Base cement was $(13.73{\pm}3.73){\times}10^4$ cells/ml and $(36.68{\pm}5.20){\times}10^4$ cells/ml at 5 and 10 days. 6. The cell number of Dentin cement was $(13.58{\pm}3.90){\times}10$ cells/ml and $(66.95{\pm}24.09){\times}10$ cells/ml at 5 and 10 days. 7. The cell multiplication rate of zinc oxide-eugenol cements was significantly less than that of the calcium hydroxide and glass ionomer cement. (P < 0.05)

  • PDF

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

상온에서 보관한 반코마이신 함유 항생제 시멘트의 메티실린 내성 포도상구균에 대한 항균력 조사 (In Vitro Study Evaluating the Antimicrobial Activity of Vancomycin-Impregnated Cement Stored at Room Temperature in Methicillin-Resistant Staphylococcus aureus)

  • 박세진;조용운;이석원;우희연;임상은
    • 대한족부족관절학회지
    • /
    • 제22권1호
    • /
    • pp.38-43
    • /
    • 2018
  • Purpose: Treatment of diabetic foot infection due to methicillin-resistant Staphylococcus aureus (MRSA) remains challenging. Applying vancomycin-impregnated cement is one of the best methods of treatment. Vancomycin-impregnated cement has been used worldwide; however, to date, there is a limited number of studies regarding its use. We evaluated the duration of antimicrobial activity of vancomycin-impregnated cement stored at room temperature after manufacturing. Materials and Methods: The vancomycin-impregnated cement was manufactured by mixing 1 g of vancomycin with 40 g of polymer and adding 17.90 g of liquid monomer. The cement dough was shaped into flat cylinders with diameter and height of 6 mm and 2 mm, respectively. Another cement of the same shape without mixing vancomycin was prepared as the negative control. All manufactured cements were sterilized with ethylene oxide gas and stored at room temperature. Each cement was placed on Mueller Hinton agar plate lawned with standard MRSA strain. Standard vancomycin disk and gentamicin disk were placed together. After 24 hours, the diameter of inhibition zone was measured, and if the diameter was less than 15 mm, vancomycin-impregnated cement was regarded as a loss of antimicrobial activity. The study was repeated every 2 weeks until vancomycin-impregnated cements lost their antimicrobial activity. Results: Vancomycin-impregnated cement stored for a duration of 16 weeks created a 14 mm inhibition zone, while vancomycin disk created a 15 mm inhibition zone. Vancomycin-impregnated cement stored for a duration of 17 weeks created 7 mm and 9 mm inhibition zones, while vancomycin disk created 16 mm and 15 mm inhibition zones, respectively. Conclusion: We found a decrease of antimicrobial activity in vancomycin-impregnated cements after 16 weeks. After 17 weeks, they showed definite loss of antimicrobial activity. Therefore, we recommend not using vancomycin-impregnated cement spacers that has been stored for more than 16 weeks at room temperature.

주상체의 비선형 운동(I) -강제동요문제, 조파저항문제- (The Nonlinear Motions of Cylinders(I))

  • 이호영;황종흘
    • 대한조선학회논문집
    • /
    • 제29권4호
    • /
    • pp.114-131
    • /
    • 1992
  • 본 논문은 2차원 자유표면파문제에서 시간영역해법을 이용하여 2차원 운동문제에 적용할 수 있는 수치해석을 하였다. 경계조건으로는 엄밀한 물체표면 경계조건과 비선형 자유표면경계 조건을 부과했다. 수치해를 구하는데는 코시이론을 이용하여 제2종 프레드흘름 경계적분방정식을 도출하고 이를 이산화시켜 처리하였다. 수치계산을 위해 전영역을 유한한 영역으로 제한하여야 한다. 제한된 영역에서 방사해의 부과를 위해 전영역을 수치해석영역과 외부영역으로 나누고, 외부영역의 해는 그린 제2정리를 이용하고, 선형자유표면조건을 만족하는 과도그린함수를 사용한다. 위의 그린 제2정리를 이용한 식으로 부터 초기조건, 선형 자유표면조건, 무한원방조건을 이용하여 단순화시킨 다음 포텐셜과 유동함수의 관계식으로 치환하면 비선형해와 정합할 수 있는 정합행렬을 구할 수 있다. 본 논문에서 개발한 정합방법을 이용하여 적용할 문제로서 첫째는 주상체가 상하동요, 수평동요하는 경우 계산이고 두번째로는 수면하에서 타원형실린더가 일정속도로 항진할 때 계산을 수행한 결과를 고차스펙트럴방법과 비교하였다.

  • PDF

직접인장시험에 의한 원형 비부착면이 삽입된 신.구 콘크리트의 부착강도 및 파괴에너지 산정 (Determination of Bond Strength and Fracture Energy of a Bi-material Cylinder with Peny-shaped Interface Crack by Pull-off Test)

  • 양성철;김진철;박종원
    • 한국도로학회논문집
    • /
    • 제6권1호
    • /
    • pp.47-56
    • /
    • 2004
  • 신 구 콘크리트의 부착강도 시험시 두 재료의 계면에서 파괴가 유도되어 순수한 부착강도를 측정할 수 있도록 계면에 원형의 비부착면을 삽입하여 직접인발시험에 의해 부착강도를 측정하는 실험방법을 제시하였다. 먼저, 새로 제안한 실험방법에 의해 계면에서 응력이 집중되는 정도를 파악하기 위해 유한요소해석을 수행하여 두 재료의 탄성계수비 및 비부착면의 면적 (균열률)에 따른 계면에서의 파괴에너지를 산정하였으며, 부재의 크기 및 하중에 대한 보정을 감안하여 무차원함수로 환산하였다. 그리고 본 연구에서 제시된 부착강도 시험방법의 신뢰성을 입증하기 위해, 3가지 크기의 원형 비부착면(균열률 0.2, 0.4. 0.6)이 삽입된 신 구 콘크리트 복합시편(유황 폴리머 콘크리트+보통 콘크리트)을 사용하여 부착강도를 측정하였고 앞서 전개된 무차원함수로부터 계면 파괴에너지를 역산하였다. 시험결과, 모든 시편이 계면에서 파괴가 유도되었다. 또한 실험 데이터 및 해석결과를 분석하여 균열률이 0.4$\sim$0.6인 경우에 부착강도의 오차가 가장 적게 발생될 수 있음을 파악하였다.

  • PDF

튜닝댐퍼를 갖는 초대형 저속 2행정 디젤엔진의 비틀림진동 특성에 관한 연구 (A Study on the Torsional Vibration Characteristics of Super Large Two Stroke Low Speed Diesel Engines with Tuning Damper)

  • 이돈출;로날드디.바로
    • 한국소음진동공학회논문집
    • /
    • 제19권1호
    • /
    • pp.64-75
    • /
    • 2009
  • 최근 조선소에서 고출력 디젤엔진의 요구에 의해서 초대형 저속 2행정 디젤엔진이 개발되었으며, 연속최대출력이 $8{\sim}14$실린더를 갖는 10만 마력 이상의 엔진을 사용할 수 있게 되었다. 이러한 엔진들은 열효율, 운전에 대한 신뢰성, 강인성 및 기동성은 뛰어나지만 크랭크축을 포함한 추진축계에서 높은 비틀림진동을 유발한다. 따라서 이 연구에서는 엔진설계자의 입장에서 비틀림진동을 줄이기 위하여 튜닝 비틀림진동 댐퍼를 갖는 추진축계의 비틀림진동을 이론적으로 검토하였으며 실험모델인 12K98MC엔진과 12RT-flex엔진에서 튜닝댐퍼의 성능과 동적거동을 확인하고 있다.

삼차원 시.공간을 이용하는 프레젠테이션 공동저작 시스템 (Collaborative Authoring System using 3D Spatio-Temporal Space)

  • 이도형;성미영
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제9권6호
    • /
    • pp.623-634
    • /
    • 2003
  • 본 논문에서는 시간 편집 환경과 공간 편집 환경을 하나의 삼차원 저작 환경으로 통합한 멀티미디어 프레젠테이션 공동 저작 시스템을 소개한다. 본 저작 시스템은 하나의 삼차원 좌표계에서 멀티미디어 프레젠테이션의 공간 속성과 시간 속성을 동시에 표현한다. 한 개의 축은 일반적인 시간 정보(T-zone)를 표현하고 나머지 두개의 축은 공간 정보(XY-zone)를 나타내며 시간적인 미디어 객체들은 삼차원 육면체로 표현하고 오디오 객체는 원통 모양으로 표현하고 있으므로, 사용자들이 자유자제로 삼차원공간을 이동하며 시간 편집과 공간 편집을 할 수 있어 효율적이다. 또한 본 논문에서는 제안하는 공동 저작 시스템에서 생성되는 공유 객체들에 대한 효율적인 동시성 제어 기법을 설계하고 구현하였다. 구현된 동시성 제어 기법은 다중버전 기법(multiple versions)을 가시화하여 공동 저작에서의 사용자 인지(user awareness)를 높였으며 공유 객체에 대한 접근허가권(access permissions)을 이용하여 네트워크 통신에서의 지연이나 장애로 발생할 수 있는 충돌(collision)을 최소화하였다. 그리고 이 동시성 제어 기법은 잠금 단위를 세밀하게 하여 사용자의 편집 자유도를 최대한 보장하였으며, 공유 객체의 일관성을 유지하면서 낙관적 동시성 제어(optimistic concurrency control)를 지원하므로 사용자들에게 멀티미디어 프레젠테이션을 동시 편집할 때 빠른 응답 시간을 제공할 수 있다.

LPG 잔류물질의 성분 및 조성 분석 (The Component and Compositional Analysis of Trace Materials in LPG)

  • 김영구
    • 대한화학회지
    • /
    • 제46권4호
    • /
    • pp.317-323
    • /
    • 2002
  • 국내에서 유통되고 있는 LPG중의 잔류물질을 분석하였다. 시료 채취 장소는 LPG용기 재검사장의 용기 2곳, LPG집단공급시설 기화기 6곳 및 LPG충전소의 압축기 오일 1곳이었다. LPG용기재검사장의 용기내 잔류물질의 성분은 alkene, diene계통의 물질(탄산소$\leq$9), 방향족 탄화수소와 타르성 화학물질 (탄소수$\geq$10)으로서 각가 1.5∼39.9%, 0.7%, 57.8∼96.0%이었다. 반면에 LPG집단공급시설의 잔류물질 및 LPG 충전소 오일 중의 타르성 화학물질은 96.6%이상이었다. 채취한 9가지 시료는 3가지 군집으로 분류되었다. SE사 용기 재검사장 시료 (SE사 시료와 S사 LPG 용기 재검사장 시료와의 유클리디안 RMS 거리=2.11), S사 LPG용기재검사장 시료 (집단공급시설시료 군과의 유클리디안 RMS거리=0.110), 집단공급시설 시료군(유클리디안 RMS거리〈0.075)이다. LPG 집단공급시설 시료의 성분이 LPG충전소 압축기오일의 조성과 매우 유사하고, 충전소 오일의 밀도와 집단공급시설의 시료 밀도가 각각 0.873, 0.873 $\pm$0.00798 (99% 신뢰구간)인 것으로 보아 타르성 화학물질은 LPG유통과정의 압축기 오일로부터 유입한 것으로 추정한다

레진시멘트, 표면처리 및 열순환에 따른 IPS Empress의 전단결합강도 (EFFECTS OF RESIN CEMENTS, CERAMIC SURFACE TREATMENTS AND THERMOCYCLING ON SHEAR BOND STRENGTH OF IPS EMPRESS CERAMIC)

  • 한정민;유영대;이용근;임미경;이수종
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.473-481
    • /
    • 1999
  • This study evaluated the shear bond properties of IPS Empress glass ceramic to enamel and dentin surfaces with three ceramic surface treatments, and three resin cements. The influence of thermocycling was also investigated. The purpose of this study was to investigate the influences of resin cements, ceramic surface treatments, and thermocycling on shear bond properties. Ninety freshly extracted, noncarious human molars were selected for this study. The surface treatments of ceramic were etching <5.0% hydrofluoric acid, application of silane coupling agents(Tokuso Ceramic Primer, Clearfil porcelain bond, Monobond-S), and the combination of the two methods. Empress cylinders were bonded to enamel and dentin surfaces with three kinds of resin cements(Bistite resin cement, Panavia 21, Variolink). The specimens were aged in $37^{\circ}C$ distilled water for 24 hours. Half of the specimens were then thermocycled 500times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 15 seconds. Each specimen was debonded in shear mode and measured shear bond properties by using the universal testing machine(Zwick 020, Germany). The data were analyzed by SPSS/PC+(one-way ANOVA, Scheffe' s test and t-test). The results were as follows : 1. Without thermocyling, there was significant difference of shear bond strength to enamel surface between Bistite Resin Cement and Panavia 21 in case of etched and silane-treatment(p<0.05). 2. Without thermocyling, the shear bond strength of a group treated with silane and etching was significantly higher than that of a group treated with silane or etching with the application of Panavia 21 and Variolink(p<0.05). 3. A group treated with etching with the application of Variolink only showed a decrease of shear bond strength after thermocycling(p<0.05).

  • PDF