• 제목/요약/키워드: cylinders

검색결과 1,179건 처리시간 0.034초

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

주상체(柱狀體)의 운동(運動) 및 표류력(漂流力)에 미치는 해류(海流)의 영향(影響) (Current Effect on the Motion and Drift Force of Cylinders Floating in Waves)

  • 이세창
    • 대한조선학회지
    • /
    • 제23권4호
    • /
    • pp.25-34
    • /
    • 1986
  • A two-dimensional linear method has been developed for the motion and the second-order steady force arising from the hydrodynamic coupling between waves and currents in the presence of a body of arbitrary shape. Interaction between the incident wave and current in the absence of the body lies in the realm beyond our interest. A Fredholm integral equation of the second kind is employed in association with the Haskind's potential for a steadily moving source of pulsating strength located in or below the free surface. The numerical calculations at the preliminary stage showed a significant fluctuation of the hydrodynamic forces on the surface-piercing body. The problem is approximately solved by using the asymptotic Green function for $U^2{\rightarrow}0$. The original Green function, however, is applied for the fully submerged body. Numerical calculations are made for a submerged and for a half-immersed circular cylinder and extensively for the mid-ship section of a Lewis-form. Some of the results are compared with other analytical results without any available experimental data. The current has strong influence on roll motion near resonance. When the current opposes the waves, the roll response are generally negligible in the low frequency region. The current has strong influence on roll motion near resonance. When the current opposes the wave, the roll response decreases. When the current and wave come from the same direction, the roll response increases significantly, as the current speed increases. The mean drift forces and moment on the submerged body are more affected by current than those on the semi-immersed circular cylinder or on the ship-like section in the encounter frequency domain.

  • PDF

탄성파의 변형 및 응력 계산에 관한 연구 (Elastic Wave Field Calculations)

  • 이정기
    • 전산구조공학
    • /
    • 제10권2호
    • /
    • pp.213-223
    • /
    • 1997
  • 탄성파의 변형 및 응력계산에 관한 연구는 비파괴검사를 비롯하여 광범위한 공학분야에서 중요한 역할을 하고 있다. 특히 파형의 산란문제가 많은 연구자들에 의해 다양한 방법으로 연구되고 있다. 실린더 또는 구와 같은 간단한 형상을 지닌 산란체에 대하여, 정상상태 탄성파의 산란문제의 해석은 해석적 기법을 이용한 연구가 가능하다. 하지만 임의의 형상을 갖는 산란체 또는 다수의 함유체에 대한 해석에는 수치해석방법이 요구된다. 예를 들면, 무한요소법 또는 Global-Local 유한요소법이라고 하는 혼성 유한요소법과 같은 특수한 유한요소법등이 개발되고 있다. 최근에는 경계요소법을 사용한 산란문제의 해석에 대한 연구가 진행되고 있다. 본 논문에서는 다수의 임의의 형상을 갖는 함유체, 공동 또는 크랙을 포함하고있는 무한고체에서의 일반적인 탄성동력학 문제를 해석하기 위해 새롭게 개발된 체적적분 방정식법을 소개한다. 또한 경계요소법을 사용하여 탄성파의 산란문제에 대한 수치해석을 수행하였으며, 이의 결과를 체적적분 방정식법의 결과와 비교 검토 하였다.

  • PDF

Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface

  • Kursoglu, Pinar;Karagoz Motro, Pelin Fatma;Yurdaguven, Haktan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.98-103
    • /
    • 2013
  • PURPOSE. To evaluate the effects of hydrofluoric acid etching and Er,Cr:YSGG laser irradiation on the shear bond strength of resin cement to lithium disilicate ceramic. MATERIALS AND METHODS. Fifty-five ceramic blocks ($5mm{\times}5mm{\times}2mm$) were fabricated and embedded in acrylic resin. Their surfaces were finished with 1000-grit silicon carbide paper. The blocks were assigned to five groups: 1) 9.5% hydrofluoric-acid etching for 60 s; 2-4), 1.5-, 2.5-, and 6-W Er,Cr:YSGG laser applications for 60 seconds, respectively; and 5) no treatment (control). One specimen from each group was examined using scanning electron microscopy. Ceramic primer (Rely X ceramic primer) and adhesive (Adper Single Bond) were applied to the ceramic surfaces, followed by resin cement to bond the composite cylinders, and light curing. Bonded specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strengths were determined by a universal testing machine at 1 mm/min crosshead speed. Data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests (${\alpha}$=0.05). RESULTS. Adhesion was significantly stronger in Group 2 ($3.88{\pm}1.94$ MPa) and Group 3 ($3.65{\pm}1.87$ MPa) than in Control group ($1.95{\pm}1.06$ MPa), in which bonding values were lowest (P<.01). No significant difference was observed between Group 4 ($3.59{\pm}1.19$ MPa) and Control group. Shear bond strength was highest in Group 1 ($8.42{\pm}1.86$ MPa; P<.01). CONCLUSION. Er,Cr:YSGG laser irradiation at 1.5 and 2.5 W increased shear bond strengths between ceramic and resin cement compared with untreated ceramic surfaces. Irradiation at 6 W may not be an efficient ceramic surface treatment technique.

위성 발사체 구조 개발을 위한 음향/진동 연구 (An overview of acoustic and vibration research activities for the structural development of Korean space launchers)

  • 박순홍
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.342-350
    • /
    • 2020
  • 본 논문은 우주 발사체 구조 개발을 위한 음향/진동 연구의 개요와 음향 해석 및 시험 기술의 국내 현황을 소개하고 있다. 먼저 발사체 운용중에 받는 동하중에 대하여 요약, 정리하고 위성체를 보호하기 위한 페이로드 페어링의 음향 하중 저감 설계 및 해석 방법을 소개하였다. 나로호부터 현재 한국형발사체 페이로드 페어링까지 음향 보호 시스템의 최적 설계를 위해 구조 진동-음향 연성 해석 성능의 향상을 도모하였으며, 이를 위한 연구 활동을 살펴보았다. 구체적으로 적층 구조가 다른 복합재료 실린더에 대한 음향 하중 저감 성능 해석 및 검증 시험, 음향 공명기 배열을 적용하기 위한 인클로저 음향 시험, 나로호 페어링 실린더부에 대한 음향 가진 시험 및 해석 등의 결과를 소개하였다. 현재 개발중인 한국형 발사체(누리호)의 페이로드 페어링 음향 하중 저감 해석 및 시험 결과를 소개하였으며 해석 결과가 실험 결과를 잘 예측함을 보였다.

Influence of the cylinder height on the elasto-plastic failure of locally supported cylinders

  • Jansseune, Arne;De Corte, Wouter;Vanlaere, Wesley;Van Impe, Rudy
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.291-302
    • /
    • 2012
  • Frequently, steel silos are supported by discrete supports or columns to permit easy access beneath the barrel. In such cases, large loads are transferred to the limited number of supports, causing locally high axial compressive stress concentrations in the shell wall above the supports. If not dealt with properly, these increased stresses will lead to premature failure of the silo due to local instability in the regions above the supports. Local stiffening near the supports is a way to improve the buckling resistance, as material is added in the region of elevated stresses, levelling these out to values found in uniformly supported silos. The aim of a study on the properties of local stiffening will then be to increase the failure load, governed by an interaction of plastic collapse and elastic instability, to that of a discrete supported silo. However, during the course of such a study it was found that, although the failure remains local, the cylinder height is also a parameter that influences the failure mechanism, a fact that is not properly taken into account in current design practice and codes. This paper describes the mechanism behind the effect of the cylinder height on the failure load, which is related to pre-buckling deformations of the shell structure. All results and conclusions are based on geometrically and materially non-linear finite element analyses.

침수식생 개수로에서 난류 및 부유사 이동 특성 (Characteristics of Turbulent Flows and Suspended Sediment Transport in Open-channel with Submerged Vegetation)

  • 양원준;장지연;최성욱
    • 한국수자원학회논문집
    • /
    • 제44권5호
    • /
    • pp.417-427
    • /
    • 2011
  • 침수식생 개수로 흐름은구조적으로상부영역과식생영역으로구분되는데, 상부영역은 일반 개수로의 흐름특성을 보이며 식생영역은 줄기에 의해 난류가 억제되어 정수식생 조건의 흐름과 유사하게 단순한 흐름특성을 보인다. 본 논문은 침수식생 개수로 흐름의 난류 및 유사이동 특성에 관한 실험연구이다. 이를 위해 폭 0.5m, 길이 12m인 개수로 실험장치를 이용하여수리실험을 실시하였다. 다양한 유량에 대하여 수심비 2~3인 흐름을 구현하였고, 나무원형 실린더를 이용하여 식생을 재현하였다. 평형상태에서 부유사 농도 분포를 측정하기 위해서중앙입경이 75 ${\mu}M$인 모래를 한계조건에 도달하기까지 지속적으로 투입하였다. 유속 성분의 계측을 위하여 레이저 도플러 유속계를 사용하였고, 튜브를 이용한 사이포닝 방식으로 시료를 직접 채취하여 부유사 농도를 측정하였다. 측정된 자료를 이용하여 실험조건에 따른 평균흐름과 난류량의 특성을 살펴보았고, Rouse 수에 따른 부유사 농도 분포를 제시하였다.

기계적합금화법에 의해 제조된 W-20wt.%Cu복합재의 치밀화 거동 (Densification Behavior of W-20wt.% Cu Composite Materials Fabricated by Mechanical Alloying Method)

  • 김보수;안인섭
    • 한국재료학회지
    • /
    • 제5권6호
    • /
    • pp.627-632
    • /
    • 1995
  • 고출력 IC회로의 방열재료 및 전기접점재료로 이용되고 있는 W-Cu복합재료를 기계적합금화법으로 제조하였다. 기계적합금화한 분말을 300MPa로 폭 16mm, 높이 4mm의 원반형으로 제조하였다. 소결은 120$0^{\circ}C$에서 140$0^{\circ}C$까지 수소분위기에서 행하였다. 이렇게 제조된 시편의 절단된 면을 연마하여 SEM으로 관찰하였다. 균질한 W-Cu복합재료를 10시간 기계적합금화를 행한 후에 얻을 수 있었고, 133$0^{\circ}C$에서 1시간 소결한 시편의 경우 거의 99%에 가까운 치밀한 조직을 얻을 수 있었다. 또한 기계적합금화시간이 증가함에 따라서 Fe의 혼입은 직선적으로 증가하였으며, 이로 인한 금속간화합물상의 형성은 W입자 성장을 방해하고 경도를 증가시켰다.

  • PDF

Bond strength of self-adhesive resin cements to composite submitted to different surface pretreatments

  • dos Santos, Victor Hugo;Griza, Sandro;de Moraes, Rafael Ratto;Faria-e-Silva, Andre Luis
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.12-16
    • /
    • 2014
  • Objectives: Extensively destroyed teeth are commonly restored with composite resin before cavity preparation for indirect restorations. The longevity of the restoration can be related to the proper bonding of the resin cement to the composite. This study aimed to evaluate the microshear bond strength of two self-adhesive resin cements to composite resin. Material and Methods: Composite discs were subject to one of six different surface pretreatments: none (control), 35% phosphoric acid etching for 30 seconds (PA), application of silane (silane), PA + silane, PA + adhesive, or PA + silane + adhesive (n = 6). A silicone mold containing a cylindrical orifice ($1mm^2$ diameter) was placed over the composite resin. RelyX Unicem (3M ESPE) or BisCem (Bisco Inc.) self-adhesive resin cement was inserted into the orifices and light-cured. Self-adhesive cement cylinders were submitted to shear loading. Data were analyzed by two-way ANOVA and Tukey's test (p < 0.05). Results: Independent of the cement used, the PA + Silane + Adhesive group showed higher microshear bond strength than those of the PA and PA + Silane groups. There was no difference among the other treatments. Unicem presented higher bond strength than BisCem for all experimental conditions. Conclusions: Pretreatments of the composite resin surface might have an effect on the bond strength of self-adhesive resin cements to this substrate.

Effects of solvent volatilization time on the bond strength of etch-and-rinse adhesive to dentin using conventional or deproteinization bonding techniques

  • de Sousa, Jose Aginaldo Junior;Carregosa Santana, Marcia Luciana;de Figueiredo, Fabricio Eneas Diniz;Faria-e-Silva, Andre Luis
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.202-208
    • /
    • 2015
  • Objectives: This study determined the effect of the air-stream application time and the bonding technique on the dentin bond strength of adhesives with different solvents. Furthermore, the content and volatilization rate of the solvents contained in the adhesives were also evaluated. Materials and Methods:Three adhesive systems with different solvents (Stae, SDI, acetone; XP Bond, Dentsply De Trey, butanol; Ambar, FGM, ethanol) were evaluated. The concentrations and evaporation rates of each adhesive were measured using an analytical balance. After acid-etching and rinsing, medium occlusal dentin surfaces of human molars were kept moist (conventional) or were treated with 10% sodium hypochlorite for deproteinization. After applying adhesives over the dentin, slight air-stream was applied for 10, 30 or 60 sec. Composite cylinders were built up and submitted to shear testing. The data were submitted to ANOVA and Tukey's test (${\alpha}=0.05$). Results: Stae showed the highest solvent content and Ambar the lowest. Acetone presented the highest evaporation rate, followed by butanol. Shear bond strengths were significantly affected only by the factors of 'adhesive' and 'bonding technique' (p < 0.05), while the factor 'duration of air-stream' was not significant. Deproteinization of dentin increased the bond strength (p < 0.05). Stae showed the lowest bond strength values (p < 0.05), while no significant difference was observed between XP Bond and Ambar. Conclusions: Despite the differences in content and evaporation rate of the solvents, the duration of air-stream application did not affect the bond strength to dentin irrespective of the bonding technique.