• Title/Summary/Keyword: cylinder type

검색결과 852건 처리시간 0.028초

원형 Cylinder 주위의 Vortex Shedding에 관한 수치 해석 연구 (A Numerical Study of laminar vortex-shedding past a circular cylinder)

  • 김태균;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.33-38
    • /
    • 2000
  • A Numerical study of laminar vortex-shedding past a circular cylinder has been performed widely by many researchers. Many factors, such as numerical technique and domain size, number and shape of grid, affected predicting vortex shedding and Strouhal number. In the present study, the effect of convection scheme, time discretization methods and grid dependence were investigated. The present paper presents the finite volume solution of unsteady flow past circular cylinder at Re=200, 400. The Strouhal number was predicted using UDS, CDS, Hybrid, Power-law, LUDS, QUICK scheme for convection term, implicit and crank-nicolson methods for time discretization. The grid dependence was investigated using H-type mesh and O-type mesh. It also studied that the effect of mesh size of the nearest adjacent grid of circular cylinder. The effect of convection scheme is greater than the effect of time discretization on predicting Strouhal. It has been found that the predicted Strouhal number changed with mesh size and shape.

  • PDF

실린더 블록 사이의 냉각수 유입홀이 대형 디젤엔진의 냉각성능에 주는 영향 (Effect of Coolant Flow Passages Between Cylinder Blocks on the Cooling Performance of a Heavy-duty Diesel Engine)

  • 이상규;임동렬;이상업;김민정;유승현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.341-344
    • /
    • 2006
  • In this analytical study on the engine coolant flow of a heavy-duty diesel engine with 4 valves and linear-type 8 liter 6 cylinders, the characteristics of pressure drop and engine cooling performance with the additional coolant passages between cylinder blocks have been investigated. Since the most part of pressure drop is caused by the coolant flow passages inside a cylinder head and cylinder blocks for this type of heavy-duty diesel engines, the advantage of pressure drop is just 2.6% and the characteristics of heat transfer and the distribution of coolant velocities in the head part show little differences in case of additional coolant passages. Thus the coolant flow passages between cylinder blocks make little contribution on the cooling performance of heavy-duty diesel engines

  • PDF

금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생 (Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

강철재도어에서 현장가공조립이 용이한 도어락상자틀 보강방법에 대한 연구 (A Study on the Reinforcement Method of the Door Lock Box Frame for Easy Field Processing Assembly in Steel Door)

  • 임보혁;이주원;조성권;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2023
  • In general, all buildings are equipped with various types of handles for opening and closing the door, and unlike wooden doors, steel doors such as fire doors are equipped with a box-shaped door lock box frame surrounding the outside of the door lock to protect the door lock, which is called a cylinder protection cover. These cylinder protection covers have various types and types of fastening structures, and the cylinder protection covers on the market are molded in factories and standardized according to the size and shape of the door lock, requiring various types of cylinder protection covers. Accordingly, a variable cylinder protection cover with a simple prefabricated structure that can fundamentally solve these problems can be used as one cylinder protection cover regardless of the type, shape, and size of the door lock.

  • PDF

해양플랜트·선박용 전기실린더형 액추에이터를 탑재한 L타입 데빗의 설계 및 구조강도에 관한 연구 (A Study on The Design and Structural Strength of L-Type Davit with Electric Cylinder Type Actuator for Offshore Plant and Ship)

  • 김영훈;곽다승;박기현;심재린;조용원
    • 한국산업융합학회 논문집
    • /
    • 제26권1호
    • /
    • pp.175-181
    • /
    • 2023
  • In offshore plants, various equipments including cranes and davits are used for safety management. Hydraulic cylinder type actuators are mainly used for luffing operations such as cranes and davits. However, in the case of a cylinder using hydraulic pressure, a separate power pack is required to supply hydraulic pressure. When used for a long time, maintenance costs such as sticking of hydraulic valves, contamination of hydraulic oil and deterioration of hydraulic hoses occur. In addition, a lot of hydraulic oil is used in the handling of cranes and davits, which causes marine pollution due to management problems. As a result, as interest in marine pollution prevention has increased recently, interest in actuators that do not use hydraulic pressure is also increasing. Therefore, in this study, we intend to develop a davit with an electric cylinder type actuator that uses electricity rather than hydraulic pressure by the SOLAS regulation. In other words, the conceptual design of the davit driven through the linear motion of the ball screw using electricity is performed, and the structural safety of the drive is also reviewed so that it can be utilized in the industrial field.

3종의 임프란트 형태에 관한 연구 (THE STUDY ON THE IMPLANT GEOMETRY)

  • 이용찬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.245-252
    • /
    • 1996
  • The purpose of this study was to develop the implant which has superior stress distribution and primary stability to others by using Instron test and finite element method. The model used in the experiment were cylinder type implant, tapered screw type implant, screw type implants. Recognizing that the number of samples were small and the lack of applying press-fit conditions to the cylinder type, we can make the following conclusions.

  • PDF

팽창실과 파퍼 실린더의 배열형태에 따른 복합소호 모델 가스차단부의 열적회복특성 비교 (Comparison of Thermal Recovery Characteristics of Hybrid Type Model Gas Interrupters According to the Arrangement of Thermal Expansion Chamber and Puffer Cylinder)

  • 송기동;정진교;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.725-731
    • /
    • 2004
  • In this study, the three type hybrid interrupters according to the arrangement of the thermal expansion chamber and the puffer cylinder(they are called 'serial type', 'parallel/exchanged type', and 'parallel/separated type' respectively in this work) were designed and manufactured. This paper presents the tested results of the thermal recovery characteristics on the interrupters using a simplified synthetic test facility. The 'serial type' hybrid interrupter which is to obtain more easily the pressure rise for the thermal recovery compared with the others has the best capability in the thermal recovery characteristics. In order to investigate the stress on the operating mechanism, the distortion of the stroke wave in on-load test was examined to the stroke curve in no-load test. The biggest distortion was occurred in the 'parallel/exchanged type' hybrid interrupter. Finally, the small interruption capability on the three type interrupters was estimated by a theoretical form and the 'parallel/separated type' hybrid interrupter has the advantage of the others in the view of structure.

사축식 유압 피스톤 펌프의 디스크 편심률에 따른 실린더블록 구동영역에 대한 연구 (A Study on Driving Range of Cylinder Block to Eccentricity Ratio of Disk in Bent axis Type Oil Hydraulic Piston Pump)

  • 정재연;백일현;조인성;송규근;오석형;정용욱
    • 유공압시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2008
  • To improve the performance of the bent axis type axial piston pump driven by the tapered piston, it is necessary to know the driving characteristics and mechanism of the tapered piston and the cylinder block. Since each piston not only rotates on its axis and reciprocates in the cylinder bore, but also revolves around the axis of the driving shaft, it is difficult to analyze the driving mechanism theoretically. The theoretical mechanism far the bent axis type axial piston pump is studied by using the geometrical method. The driving range of the tapered piston is determined by theoretical equations. The results show that the cylinder block is driven by one tapered piston in a limited range and the core parameters such as driving factor of the piston and the ahead delay angle influenced performance of the bent axis type axial piston pump.

  • PDF

부분 슬롯을 가진 다공성 실린더의 내부 유동 가시화 (Flow Visualization in Porous Cylinder with Partial Slots)

  • 손민;김도헌;구자예;장홍빈;강문중
    • 항공우주시스템공학회지
    • /
    • 제8권3호
    • /
    • pp.1-5
    • /
    • 2014
  • An inner flow of a porous cylinder with partial slots was visualized to study fluidic phenomena in a solid rocket motor. A high-pressure chamber and an air supply system for high flow rate were used. In order to visualize the inner flow, the smoke generator with a cam-driven pump and heaters and high speed camera were adopted. The results of the cylinder type and the partial slot type were compared. As a result, the injected smoke flow in the partial slot type had circumferential fluctuations unlike the cylinder type. It was found that the circumferential flow induced from the partial slots could be the cause of combustion instability and roll torque.