• Title/Summary/Keyword: cylinder probability

Search Result 24, Processing Time 0.017 seconds

Construction and a Chronological Examination of the Fabrics in the Buddhist (불복장 직물의 구조특성 및 연대규명)

  • Kim, Sun-Kyung;Cho, Hyo-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.8 s.99
    • /
    • pp.73-84
    • /
    • 2005
  • Collections in the buddhist statue owned by Dr. Jong-Hm Baik(白宗欽) included 3 ancient documents and 2 wooden cylinders that showed a clear historical order. The temple and buddhist statue that these objects were belonged to were not known, however, according to the document, it could be inferred as Chunsukwaneumsang(천수관음상) created in 1322 and reformed in 1614 from the list of donator for the statue. Inside a wooden cylinder, a bundle of ivory, yellow, green, orange, and dark brown fabrics that were folded up and tided up with 5 different colored thread strands and aromatic trees and rice plant was placed on the bottom. All the fabrics were silk. Three thread strands were silk. The white and blue strands were cotton fibers as a result of analysis of IR spectrum and the microscope. According to a radioactive carbon isotope dating by accelerator mass spectroscopy, years before present was 160$\pm$40, and cablibrated ages were 1680-1890 (79.3$\%$), 1910-1960(16.1$\%$) in 95.4$\%$ probability. Accordingly, the fabrics in the buddhist statue proved to be reformed in 1614 not the original ones in 1322.

A Quantitative Risk Analysis of LPG Leaked During Cylinder Delivery (가스용기 운반 중 누출된 LPG의 정량적 위험 분석)

  • Kim B-J,;Park Ki-Chang;Lee Kuen-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.33-41
    • /
    • 2003
  • There exists high hazard when transporting LPG as well as using, storing, and producing. For small scale LPG consumer, retailers deliver LPG to customers via a truck loading many LPG cylinders. Suppose there occurred a accident during LPG cylinder transfer, this could result in serious damages to the life and properties in the near or neighbor of the accident spot. In this regard, we made a quantitative risk analysis to estimate the possible damages and the probability through the identification of accidents causes and the simulation of the possible scenario. In this study, we made the Excel & Visual Basic computer program to perform quantitative LPG accident analysis. The simulation showed the following results. In case of UVCE(Unconfined Vapor Cloud Explosion), the effect within l0m of the accident spot showed very severe structural damages and even the accident can break the window glasses of the area of 150 m apart from accident spot. In case of TNT corresponding probit analysis, after 10 minutes LPG leaking, $75\%$ window glasses of 40 m distance was expected to be broken. And $16\%$ frames of 20m distance, $10\%$ frames of 40m distance was expected to be collapsed.

  • PDF

Fast Axis Estimation from 3D Axially-Symmetric Object's Fragment (3차원 회전축 대칭 물체 조각의 축 추정 방법)

  • Li, Liang;Han, Dong-Jin;Hahn, Hern-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.748-754
    • /
    • 2010
  • To reduce the computational cost required for assembling vessel fragments using surface geometry, this paper proposes a fast axis estimation method. Using circular constraint of pottery and local planar patch assumption, it finds the axis of the symmetry. First, the circular constraint on each cylinder is used. A circular symmetric pot can be thought of unions of many cylinders with different radii. It selects one arbitrary point on the pot fragment surface and searches a path where a circumference exists on that point. The variance of curvature will be calculated along the path and the path with the minimum variance will be selected. The symmetric axis will pass through the center of that circle. Second, the planar patch assumption and profile curve is used. The surface of fragment is divided into small patches and each patch is assumed as plane. The surface normal of each patch will intersects the axis in 3D space since each planar patch faces the center of the pot. A histogram method and minimization of the profile curve error are utilized to find the probability distribution of the axis location. Experimental results demonstrate the improvement in speed and robustness of the algorithms.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF