• Title/Summary/Keyword: cutoff criteria

Search Result 57, Processing Time 0.031 seconds

Optimal Cutoff Points of Rate Pressure Product in Each Stage of Treadmill Exercise Test According to the Degree of Metabolic Syndrome in Korean Adults (한국성인의 대사증후군 예방을 위한 운동부하 검사시 각 단계별 심근부담률의 적정 임계점)

  • Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.136-143
    • /
    • 2018
  • The rate pressure product (RPP) is expressed as a product of the heart rate and systolic blood pressure as an index indirectly measuring the myocardial oxygen consumption, and it indicates the burden on the myocardium. The aim of this study was to determine the optimal level of RPP for preventing metabolic syndrome in a treadmill exercise test in Korean adults. Metabolic syndrome was the diagnosis of the third executive summary report on the National Cholesterol Education Program Adult Treatment Panel III (NCEP-ATP III) criteria. According to the criteria, the metabolic syndrome diagnosis group (MetS, N=25), pre-metabolic syndrome group (Pre-MetS, N=106), and non-risk factor group (Non-MetS, N=65) were classified. The exercise stress test was performed based on the Bruce protocol. The RPP was calculated as (heart rate${\times}$systolic blood pressure)${\div}1,000$. The results showed that the maximum systolic blood pressure was high despite the low daily dose reached in the diagnostic group of metabolic syndrome. The optimal threshold of the RPP at the time of the exercise treadmill test for a metabolic syndrome prediction was $12.56mmHg{\times}beats/min{\times}10^{-3}$ in the first stage of the exercise stress test. The second stage of the exercise test was $16.94mmHg{\times}beats/min{\times}10^{-3}$, and at the third stage of the exercise test was $21.11mmHg{\times}beats/min{\times}10^{-3}$.

Development and Validation of Questionnaire for Chronic Fatigue Syndrome (CFS) Diagnosis Based on Systemic Exertion Intolerance Disease (SEID) Criteria (전신성 활동불능증(Systemic Exertion Intolerance Disease) 진단 기준을 바탕으로 한 만성 피로 증후군(Chronic Fatigue Syndrome) 진단 설문지 개발 및 신뢰도 평가)

  • Lim, Eun-jin;Son, Chang-gue;Jang, Eun-su
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.293-305
    • /
    • 2020
  • Purpose: This study aimed to develop a questionnaire for the diagnosis of chronic fatigue syndrome (CFS) designed based on the systematic exertion intolerance disorder (SEID) criteria, and to validate the reliability of the questionnaire. Methods: A literature search on questionnaires for CFS diagnosis was conducted to develop a SEID questionnaire (SEID-Q27), followed by a pilot survey to identify the reliability of the questionnaire. Adults (Daejeon university personnel) with a Chalder fatigue scale (CFQ) score ≥15 were invited for the survey. We commenced the survey in November 2019 with a two weeks of interval for the test and retest method. The reliability of the questionnaire was investigated in three angles: 1. Cronbach's α, 2. correlations (r) of the questions, numerical rating scale (NRS), and visual analog scale (VAS), and 3. kappa (k) analysis. Results: Among the total 275 adults registered, 55 (20%) participants with a CFQ score ≥15 were invited, and 31 (11%) [15 male, 16 female] completed the questionnaire. The total Cronbach's α was 0.944 for the test and 0.949 for the retest. The reliability (r) of questions by CFQ score (≥15, ≥18, ≥20) ranged from 0.533-0.928 (p <0.05), and the r score of the NRS and VAS were the highest in CFQ scores ≥20, at 0.933 (p<0.001). The agreement rate of the SEID-Q27 between the test and retest was 87% (kappa k=0.743). Conclusions: The SEID-Q27 seems to be reliable. Further studies are needed to measure the validity of the tool and the cutoff point.

Patient Specific Quality Assurance of IMRT: Quantitative Approach Using Film Dosimetry and Optimization (강도변조방사선치료의 환자별 정도관리: 필름 선량계 및 최적화법을 이용한 정량적 접근)

  • Shin Kyung Hwan;Park Sung-Yong;Park Dong Hyun;Shin Dongho;Park Dahl;Kim Tae Hyun;Pyo Hongryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Huh Sun Nyung;Kim Il Han;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.176-185
    • /
    • 2005
  • Purpose: Film dosimetry as a part of patient specific intensity modulated radiation therapy quality assurance (IMRT QA) was peformed to develop a new optimization method of film isocenter offset and to then suggest new quantitative criteria for film dosimetry. Materials and Methods: Film dosimetry was peformed on 14 IMRT patients with head and neck cancers. An optimization method for obtaining the local minimum was developed to adjust for the error in the film isocenter offset, which is the largest part of the systemic errors. Results: The adjust value of the film isocenter offset under optimization was 1 mm in 12 patients, while only two patients showed 2 mm translation. The means of absolute average dose difference before and after optimization were 2.36 and $1.56\%$, respectively, and the mean ratios over a $5\%$ tolerance were 9.67 and $2.88\%$. After optimization, the differences in the dose decreased dramatically. A low dose range cutoff (L-Cutoff) has been suggested for clinical application. New quantitative criteria of a ratio of over a $5\%$, but less than $10\%$ tolerance, and for an absolute average dose difference less than $3\%$ have been suggested for the verification of film dosimetry. Conclusion: The new optimization method was effective in adjusting for the film dosimetry error, and the newly quantitative criteria suggested in this research are believed to be sufficiently accurate and clinically useful.

Evaluation of the Humpty Dumpty Falls Scale: An Analysis of Electronic Medical Records (소아 낙상위험 측정도구 (Humpty Dumpty Falls Scale) 평가: 전자의무기록을 이용하여)

  • Cho, Yun Hee;Kim, Young Ju
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.142-150
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the efficiency of the Humpty Dumpty Falls Scale as one of the falls risk assessment tools, and also to evaluate risk factors as predictors of falls in pediatric patient populations. Methods: In a retrospective, case-control design with data from the electronic medical records of 13 pediatric patients who fell and 1,941 who did not fall before matching and 429 who did not fall after matching by gender, age, diagnosis, and length of stay. Results: All the variables showed no significant differences after matching. At the cutoff score of 13, sensitivity, specificity, negative and positive predictive values were 92.3%, 37.1%, 99.9%, and 0.01%, respectively. The area under the Receiver Operating Characteristics was 0.597. The results from the logistic regression showed that the pediatric inpatient population who had higher risk scores was significantly associated with falls. The odds ratios ranged from 1.31 to 4.71 with 90% confidence interval. Conclusion: The saturation impairments criterion as one of the diagnostic parameter was negatively associated with falls, but the relative risk score was higher than the other criteria. Therefore, it seems that the diagnostic parameter seems to be required to verify results through large sample studies.

Influence of Different Diagnostic Criteria on Frequency of Convergence Insufficiency (진단기준 차이가 폭주부족의 빈도에 미치는 영향)

  • Yu, Dong-Sik;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Purpose: This study was to investigate whether the application of different diagnostic criteria affected the frequency of convergence insufficiency (CI). Methods: Eighty one subjects with mean age of 22.54 years (20 to 27 years) were evaluated. Binocularity tests after refraction were performed as the following tests: near point of convergence (NPC) with an accommodative target, phoria using von Graefe method, positive fusional vergence (PFV) with a phoropter. Subjects with CI were diagnosed when exophoria (exo) was greater at near than at distance ($exo{\geq}4{\Delta}$, or >$6{\Delta}$), fusional vergence was $PFV{\leq}11{\Delta}$ for blur, $PFV{\leq}15{\Delta}$ for break, Sheard's or Percival's criterion, and NPC was $NPC{\geq}6cm$, ${\geq}7.5cm$ or >10 cm. Results: Frequency of CI with one diagnostic criterion was ranged from 6.2% to 77.8%, and was overestimated or underestimated according to criteria. It was reduced to the range of 6.2% to 43.2% with diagnostic criteria more than two, especially to the range of 24.7% to 28.4% with lower variability in diagnostic criteria including phoria and Sheard's criterion. There were high relationship between total score of signs and phoria score (r = 0.772, p<0.001), and measured phoria and Sheard's criterion (r = -0.654, p<0.001), but NPC had a high variability and a weak or no significant relationship with other diagnostic criteria. Results suggested $exo{\geq}4{\Delta}$, Sheard's criterion and $NPC{\geq}7.5cm$ for diagnostic criteria of signs and sequence for CI. Conclusions: Frequency of CI is likely to be over- and underestimated with diagnostic criteria. Cutoff values and procedures for phoria, Sheard's criterion and NPC as clinical signs should be suggested definitely in diagnosis associated with CI.

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Cutoff Values of Body Mass Index and Body Fat Measures for Metabolic Syndrome in Korean Population (한국인에서 대사증후군의 선별검사로서 체성분 분석 및 체질량지수의 타당성연구)

  • Lee, Hyun-Jae;Kim, Byoung-Gwon;Kim, Joon-Youn;Kim, Jung-Man;Yoo, Byung-Chul;Kim, Eun-Jeong;Hong, Young-Seoub
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This study investigated cut-off values of body mass index (BMI) and body fat measures for metabolic syndrome (MS) in elderly Koreas. Questionnaire surveys, anthropometric measurements, medical examinations, and body composition analyses were conducted for 10,077 subjects aged 40-65 years in the health examinee cohort in Korea between 2004 and 2006. Cut-off values were identified using receiver-operating characteristic (ROC) curve analysis for both men and women. Stratified analyses by weight range (<60, 60-69, 70-79, and 80-89, ${\geq}90\;kg$ for men; <50, 50-59, 60-69, 70-79, ${\geq}80\;kg$ for women) were conducted. Among male subjects, the cut-off points were $25.5\;kg/m^2$ for BMI with a sensitivity of 70.0% and a specificity of 72.0%, and 26.1% for body fat percentage with a sensitivity of 60.6% and a specificity of 76.4%. Among female subjects, the cutoff points were $24.1\;kg/m^2$ for BMI with a sensitivity of 73.3% and a specificity of 68.8%, and 31.5% for body fat percentage with a sensitivity of 76.7% and a specificity of 65.6%. Stratified analysis by weight range showed that the cutoff points of BMI and body fat measures tended to higher as weight level increased. The results of our study suggest cut-off values of BMI and body fat measure for MS were similar to the general obesity criteria in Korea.

Comparison of Nutrient Intakes of Elderly Korean and American Women Using Diet Quality Index

  • Chung, Chin-Eun;Sungsoo Cho
    • Nutritional Sciences
    • /
    • v.2 no.2
    • /
    • pp.107-112
    • /
    • 1999
  • Diet quality index DQI) offers a new way of comparing eating habits across populations and across countries. Nutrients and food consumption data from 100 elderly Korean women aged 65 and older were collected in Seoul or Kyunggi-do, Korea by the 24 hour recall method. Diet quality index (DQI) was computed for 1049 elderly women (65 and older) from the 1994-1996 Continuing Survey of Food Intakes by Individuals (CSFII) in the US according to US dietary guidelines, and applied to the diet of elderly Korean women for purposes of comparison. A modified 16-point DQI awarded 2 points each for moderate consumption of fat ($\leq$ 30% energy), saturated fat ($\leq$ 10%), cholesterol ($\leq$ 300 mg/day), sodium ($\leq$ 2400 mg/day), and protein ($\leq$ 100% RDA), adequate intakes of carbohydrate ($\qeq$50% energy) and calcium ($\qeq$ 100% RDA), and plenty of fruits and vegetables ($\qeq$ 5 servings). Criteria were based on US dietary guidelines. Partial scores were given if subjects were close to meeting these cutoff points. Diets with $\leq$ 300 mg cholesterol/day were reported by 97% or the Korean sample and 82% of the American sample, while 90% of the Koreans and 42% of the Americans met the goal of $\leq$ 30% of energy from fat, and 98% of the Koreans and 47% of American met the recommendation of $\leq$ 10% of energy from saturated fat. In contrast, only 8% of the Korean sample met the sodium recommendation of $\leq$ 2400 mg sodium per day, whereas 54% of the American subjects met this goal. The mean DQI scores were 10.1 for the elderly American women and 11.3 for the elderly Korean women. Overall, the elderly Korean diet was more consistent with the US dietary guidelines than the elderly American diet.

  • PDF

Predictive factors of symptomatic radiation pneumonitis in primary and metastatic lung tumors treated with stereotactic ablative body radiotherapy

  • Kim, Kangpyo;Lee, Jeongshim;Cho, Yeona;Chung, Seung Yeun;Lee, Jason Joon Bock;Lee, Chang Geol;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.163-171
    • /
    • 2017
  • Purpose: Although stereotactic ablative body radiotherapy (SABR) is widely used therapeutic technique, predictive factors of radiation pneumonitis (RP) after SABR remain undefined. We aimed to investigate the predictive factors affecting RP in patients with primary or metastatic lung tumors who received SABR. Materials and Methods: From 2012 to 2015, we reviewed 59 patients with 72 primary or metastatic lung tumors treated with SABR, and performed analyses of clinical and dosimetric variables related to symptomatic RP. SABR was delivered as 45-60 Gy in 3-4 fractions, which were over 100 Gy in BED when the ${\alpha}/{\beta}$ value was assumed to be 10. Tumor volume and other various dose volume factors were analyzed using median value as a cutoff value. RP was graded per the Common Terminology Criteria for Adverse Events v4.03. Results: At the median follow-up period of 11 months, symptomatic RP was observed in 13 lesions (12 patients, 18.1%), including grade 2 RP in 11 lesions and grade 3 in 2 lesions. Patients with planning target volume (PTV) of ${\leq}14.35mL$ had significantly lower rates of symptomatic RP when compared to others (8.6% vs. 27%; p = 0.048). Rates of symptomatic RP in patients with internal gross tumor volume (iGTV) >4.21 mL were higher than with ${\leq}4.21mL$ (29.7% vs. 6.1%; p = 0.017). Conclusions: The incidence of symptomatic RP following treatment with SABR was acceptable with grade 2 RP being observed in most patients. iGTV over 4.21 mL and PTV of over 14.35 mL were significant predictive factors related to symptomatic RP.

Evaluation of the role of ischemia modified albumin in neonatal hypoxic-ischemic encephalopathy

  • Talat, Mohamed A.;Saleh, Rabab M.;Shehab, Mohammed M.;Khalifa, Naglaa A.;Sakr, Maha Mahmoud Hamed;Elmesalamy, Walaa M.
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.8
    • /
    • pp.329-334
    • /
    • 2020
  • Background: Birth asphyxia is a leading cause of neonatal mortality. Ischemia-modified albumin (IMA) levels may have a predictive role in the identification and prevention of hypoxic disorders, as they increase in cases of ischemia of the liver, heart, brain, bowel, and kidney. Purpose: This study aimed to assess the value of IMA levels as a diagnostic marker for neonatal hypoxic-ischemic encephalopathy (HIE). Methods: Sixty newborns who fulfilled 3 or more of the clinical and biochemical criteria and developed HIE as defined by Levene staging were included in our study as the asphyxia group. Neonates with congenital malformation, systemic infection, intrauterine growth retardation, low-birth weight, cardiac or hemolytic disease, family history of neurological diseases, congenital or perinatal infections, preeclampsia, diabetes, and renal diseases were excluded from the study. Sixty healthy neonates matched for gestational age and with no maternal history of illness, established respiration at birth, and an Apgar score ≥7 at 1 and 5 minutes were included as the control group. IMA was determined by double-antibody enzyme-linked immunosorbent assay of a cord blood sample collected within 30 minutes after birth. Results: Cord blood IMA levels were higher in asphyxiated newborns than in controls (250.83±36.07 pmol/mL vs. 120.24±38.9 pmol/mL). Comparison of IMA levels by HIE stage revealed a highly significant difference among them (207.3±26.65, 259.28±11.68, 294.99±4.41 pmol/mL for mild, moderate, and severe, respectively). At a cutoff of 197.6 pmol/mL, the sensitivity was 84.5%, specificity was 86%, positive predictive value was 82.8%, negative predictive value was 88.3%, and area under the curve was 0.963 (P<0.001). Conclusion: IMA levels can be a reliable marker for the early diagnosis of neonatal HIE and can be a predictor of injury severity.