• 제목/요약/키워드: custom-made

검색결과 352건 처리시간 0.026초

Custom-Made ITE Type Hearing Protection Device Using a Small Acoustic Filter

  • Lee, Yun-Jung;Kim, Pil-Un;Jung, Young-Jin;Chang, Yong-Min;Cho, Jin-Ho;Kim, Myoung-Nam
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.376-383
    • /
    • 2006
  • Noise induced hearing loss (NIHS), the well-known occupational disease, is caused by continuous excessive noise. The prevention of NIHS is very important, because it is unrecoverable. There are some kinds of hearing protection device (HPD), and those are effective in preventing NIHS. But workers in noisy environment often resist to wearing them. Because they are ready - made products, so workers feel uncomfortable to wear. Also, they didn't maintain the conversation frequency range, so workers are hard to communicate in wearing them. To prevent hearing loss effectively, it is important that workers keep wearing HPD. Therefore, a HPD is needed to be comfortable to wear and be effective not only in hearing protection but also in preserving communication ability. So we proposed a custom - made hearing protection device in which a small acoustic filter is inserted. We designed several kinds of small acoustic filters and carried out some acoustic experiments for measuring characteristics of filters. We confirmed that acoustic transmission characteristic can be adjusted from experimental results using designed small acoustic filters. And we researched for the actual efficiency of a new developed custom - made hearing protection device using a small size acoustic filter. Also, we found out that workers are more satisfied with the new development than a former protection device from a workers' response.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

인공 관절 대치술로 치료한 골 종양 (Treatment of Bone Tumors with a Custom-made Prosthetic Replacement)

  • 신현국;서재성;안종철;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제8권1호
    • /
    • pp.206-214
    • /
    • 1991
  • We treated three cases of bone tumors-giant cell tumor, chondroblastoma and malignant fibrous histiocy toma-with a custom-made prosthetic replacement. The patients were followed from 10 months to 18 months, postoperatively. The results of these study are as follows : 1. satisfactory anatomic restoration 2. early ambulation 3. good function 4. biomechanically sound reconstruction.

  • PDF

Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석 (Fit analysis of CAD-CAM custom abutment using micro-CT)

  • 민광석;정재헌;김희중
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.370-378
    • /
    • 2016
  • 목적: Biomet 3i 시스템과 Astra 시스템의 내측 연결형 임플란트 고정체에 국내에서 제작된 맞춤형 CAD-CAM 지대주를 체결하여 구성 성분 간의 적합성과 나사의 안정성을 평가하고자 하였다. 재료 및 방법: 24개 3i 임플란트 중 12개의 임플란트에 기성 지대주를 연결하고, 나머지 임플란트에는 맞춤형 CAD-CAM 지대주를 연결하여 각각 Group 1과 Group 2로 분류하였다. 동일 개수와 동일한 방법으로 Astra 임플란트를 각각 Group 3와 Group 4로 분류하였다. 각각의 고정체에 지대주를 장착하여 각 계면 사이의 적합성을 micro-CT로 관찰하고 초기 풀림 토크를 측정한 후 평가하였다. 결과: 고정체-지대주의 접촉길이는 Group 1과 Group 2 사이 뿐만 아니라 Group 3와 Group 4 사이에도 유의한 차이가 없었다(Mann-Whitney test, P>.05). 하지만, 지대주와 나사의 계면 및 고정체와 나사의 계면에서 Group 2와 Group 4가 Group 1와 Group 3에 비해 각기 더 큰 접촉양상을 보여주었다(Mann-Whitney test, P<.05). 또한, Group 2와 Group 4가 Group 1과 Group 3에 비해 각기 더 낮은 나사의 초기 풀림 토크를 기록하였다(Student t-test, P<.05). 결론: CAD-CAM지대주는 임상에 적용할 만한 적합성을 지니고 있으나, 광범위한 임상 적용을 위해서는 풀림 토크가 향상되어야 할 것으로 사료된다.

Subsidence Ratio after Anterior Cervical Interbody Fusion Using an Intraoperative Custom-made Cervical Cage

  • Kim, Dok-Ryong;Moon, Byung-Gwan;Kim, Jae-Hoon;Kang, Hee-In;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.301-305
    • /
    • 2007
  • Objective : The postoperative subsidence of anterior cervical interbody fusion for cervical degenerative diseases gives rise to segmental kyphotic collapse, screw loosening, and chronic neck pain. So, intraoperative custom-made polymethylmethacrylate [PMMA] C-cage has been developed to prevent subsidence following anterior cervical fusion. Methods : A total of patients who underwent anterior cervical interbody fusion with a intraoperative custom - made cervical cage filled with local bone and demineralized bone matrix [group A] were analyzed prospectively from June 2004 to June 2005. These were compared with 40 patients who were treated with iliac bone graft [group B]. We evaluated subsidence ratio, change of segmental angle, distraction length and segmental angle. Statistical analysis was performed using independent sample t-test and Pearson correlation coefficient. Results : Group A had a statistically significant decrease in subsidence ratio [$0.64{\pm}0.43%$, p=0.00]. distraction length [$2.42{\pm}1.25\;mm$, p=0.02], and follow angle change [$1.78{\pm}1.69^{\circ}$, p=0.01] as compared with Group B. However, there was no statistically significant difference in postoperative segmental angle change [p=0.66]. On the analysis of the correlation coefficient, the parameters showed no interrelationships in the group A. On the other hand, subsidence ratio was affected by distraction length in the group B [Pearson correlation=0.448]. Conclusion : This operative technique would be contributed for the reduction of a postoperative subsidence after the anterior cervical interbody fusion procedure for cervical disc disease with moderate to severe osteoporotic condition and segmental loss of lordosis.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Management for Gait Disturbance and Foot Pain in a Patient with Klippel-Trenaunay-Weber Syndrome : A case report

  • Choi, Yoon-Hee
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.85-89
    • /
    • 2021
  • Background : Klippel-Trenaunay-Weber syndrome (KTS) is a rare congenital medical condition characterized by complex vascular malformation. KTS consists of a classic triad of capillary malformation (hemangioma), venous malformations and bone or soft tissue hypertrophy causing limb asymmetry. The aim of this report is to describe management for gait disturbance and foot pain in a Patient with KTS using custom-made total contact insole. Case presentation : A 32-year-old man with KTS presented with a 3-year history of gait disturbance on hard surface due to right first toe pain and Achilles tendon tightness. The patient had soft tissue hypertrophy, varicose veins and port-wine stains over the right lower limb associated with KTS. True leg length discrepancy was 2 cm. We prescribed custom-made total contact insole to protect his deformed foot and correct leg length discrepancy. The insole of right side included wedge shaped heel lift and the insole of left side included full length lift to add extra support on unaffected side. Also, we provided compression stocking and physiotherapy including manual lymphatic drainage for lymphedema and stretching exercise for tightness in right lower extremity. At 3 years follow-up, postural alignment including pelvic obliquity was improved using a custom-made total contact insole. The degree of scoliosis and foot pain were also reduced. Conclusion : An individualized and multidisciplinary approach is essential regarding the complexity of comorbidities in patients with KTS. For patients with KTS, orthotic management should be considered to prevent and correct deformities related to KTS. Active orthotic management, compression stocking and physiotherapy can enhance the quality of life and function in patients.

3D 핸디형 스캐너와 3D 프린팅 기술 기반 드레이핑용 커스텀 메이드 드레스폼 개발 (Development of a Custom-Made Dress Form for Draping Based on 3D Handheld Scanners and 3D Printing Technology)

  • 유은주;송화경
    • 한국의류산업학회지
    • /
    • 제24권4호
    • /
    • pp.451-459
    • /
    • 2022
  • This study aimed to develop a a custom-made dress form for draping using a live model's 3D body scan obtained from an entry-level 3D handheld scanners, 3D modeling software and 3D printing technology. A female subject was recruited whose body size fell under the normal (N) body shape criteria suggested by KS K 0051. First, the handheld scanner reduced the length of the legs in scanning, but most of the scanning operations between the neck and crotch levels were conducted accurately. Therefore, this study was designed to develop a torso dress form. The full body 3D scan was edited into a torso shape using ZBrush® software. Using Rhinoceros® and Materialise's Magics software, a 3D body scan was modeled so that the user could fit two types of mannequin stands (one with a neck fixation from above and one with an insert from below) to the dress form. The body scan was divided into 9 pieces to fit the printable size of the Stratasys 3D printer Fortus 250mc, and the cross-sectional distance from the center to the periphery was downsized by 2 mm. After outputting the dress form scan file with a 3D printer, the dress form was manufactured by the first covering it with a 4 oz nonwoven pad and the second covering with a single jersey material.

보행시 과도한 회내와 관련된 발질환을 위한 맞춤형 발보조기의 교정적 기능 (Correctional Function of Custom Foot Orthotics for Foot Diseases related to Excessive Pronation during Gait)

  • 김승재
    • 한국운동역학회지
    • /
    • 제16권1호
    • /
    • pp.65-79
    • /
    • 2006
  • The purpose of this study was firstly to investigate correctional function of custom semi-rigid foot orthotics for excessively pronated people during gait by observing comfort, navicular movement and leg muscles' activity according to short-term and mid-term wearing duration and secondly to understand positive and/or negative point of view of a recently proposed paradigm related to foot orthotics more profoundly. Sixteen subjects who showed excessive pronation at navicular drop test were recruited for this study. Custom semi-rigid foot orthotics were made fitting for foot characteristics of the subjects by podiatry division of Otto Bock Korea company. While wearing the foot orthotics for two months, comfort of wearing were questioned and vertical navicular movement and electromyography of leg muscles during gait were measured at the condition of both immediately after and 2 months after including a control condition, respectively. The subjects were required to walk on a treadmill at the speed of 1.5m/s and four digital video camera filmed the movement of navicular process at the speed of 60 frames/s. In conclusion, in excessively pronated group continuous increase of comfort from short-term to mid-term wearing of custom foot orthotics is assumed to be closely related with short-term and mid term correctional action, of which are consisted the decrease of the range of navicular drop and navicular raisins- the faster timing of minimum navicular position occurring, and the decrease of leg muscles' activities. This conclusion could lead to positively accept new paradigm related to foot orthotics suggested by Nigg and the author suggest that in the future study the variable which could observe navicular movement would be one of major variables to study preferred path of skeleton in the paradigm.