• 제목/요약/키워드: custom-made

검색결과 352건 처리시간 0.025초

쾌속 조형 기술을 이용한 바이오리액티의 개발 (Development of Bioreactor by Rapid Prototyping Technology)

  • 박정훈;이승재;이인환;조동우;이종원
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.137-143
    • /
    • 2009
  • It has been reported that mechanical stimulation takes a role in improving eel/ growth in skeletal system. Various research groups have been showed their own bioreactors which stimulate cell-seed three-dimensional scaffold. In this study, we hypothesized that the various conditions of mechanical stimulation would affect cell growth and proliferation. To prove our hypothesis, we designed a custom-made bioreactor capable of applying controlled compression to cell-encapsulated scaffolds. This device consisted of a circulation system and a compression system. Each parts of the bioreactor was fabricated using the rapid prototyping technology By using the rapid prototyping technology, we can modify and improve the bioreactor very rapidly For dynamic cell-culture, cell-encapsulated agarose gel was fabricated in 2% concentration. We performed dynamic cell-culture using this agarose gel and developed bioreactor in 3 days.

활액과 하이얼루러난이 소 연골의 마찰 특성에 작용하는 역할 (The Role of Synovial Fluid and Hyaluronan in the Frictional Response of Bovine Articular Cartilage)

  • 박성훈
    • 한국정밀공학회지
    • /
    • 제25권10호
    • /
    • pp.137-143
    • /
    • 2008
  • The objective of this study was to characterize the role of synovial fluid and hyaluronan in the frictional response of bovine articular cartilage. Seven cylindrical cartilage specimens were harvested from three fresh bovine humoral heads (4-6 months old). Reciprocal sliding motion (1mm/s) was provided by a custom-made friction testing apparatus with a normal load of 22.3 N. From the measured time-dependent normal and frictional forces, the minimum and maximum frictional coefficients were calculated. Synovial fluid reduced the minimum frictional coefficient by ${\sim}75$ % and maximum frictional coefficient by ${\sim}11%$, while the reduction of the minimum and maximum frictional coefficients with hyaluronan was ${\sim}42%$ and ${\sim}24%$, respectively. To the best of our knowledge, this experimental study investigates the first such comparisons of frictional response of articular cartilage with and without synovial fluid and hyaluronan, and provides significant insights into their role in the articular cartilage friction and lubrication.

GROUND RECEIVING SYSTEM FOR KOMPSAT-2

  • Kim, Moon-Gyu;Kim, Tae-Jung;Park, Sung-Og;Im, Yong-Jo;Shin, Ji-Hyun;Choi, Myung-Jin;Park, Seung-Ran;Lee, Jong-Ju
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.804-809
    • /
    • 2002
  • Remote sensing division of satellite technology research center (SaTReC), Korea advanced institute of science and technology (KAIST) has developed a ground receiving and processing system for high resolution satellite images. Developed system will be adapted and operated to receive, process and distributes images acquired from of the second Korean Multi-purpose Satellite (KOMPSAT-2), which will be launched in 2004. This project had initiated to develop and Koreanize the state-of-the-art technologies related to the ground receiving system fur high resolution remote sensing images, which range from direct ingestion of image data to the distribution of products through precise image correction. During four years development, the system has been verified in various ways including real operation of custom-made systems such as a prototype system for SPOT and a commercialised system for KOMPSAT-1. Currently the system is under customisation for installation at KOMPSAT-2 ground station. In this paper, we present accomplished work and future work.

  • PDF

대형옹관의 제작기법 연구-영산강유역 출토 옹관을 중심으로 (A study on manufacturing technologies of the large-sized jar-coffins exhumed mainly in the Young San river area)

  • 양필승;박철원
    • 보존과학연구
    • /
    • 통권26호
    • /
    • pp.57-75
    • /
    • 2005
  • The burial custom in the Youngsan river area was to build a jar-coffin and lay the body in state, however the methods in building and moulding the massive jar, as well as in which kiln it was made has not been examined precisely. Thus, this research not only investigates previous results related to the manufacturing methods of massive jar-coffins, but also examines samples that were excavated and collected. The clay used to produce jar-coffin consists a large portion of unglazed qualities, which was split-moulded from the bottom up to the mouth area. The interior was finished by applying water, whereas the exterior was decorated by regularly pasting or stamping in parallel with a lattice design. It can be presumed that the finished jar-coffin was not moved, but the ceiling and walls were built around it as a kiln, for the jar-coffin to be oxidized or to reduce the flame condition in a temperature approximately $700~1,200^{\circ}C$The results from the research, however, show limitations to exploit the exact manufacturing method, therefore there is a need for in-depth examinations: mineralogical investigation on a large amount of jar-coffin samples through a polarized light microscope; substance analysis using various equipments; speculation on the temperature in the place of production and the flame inside.

  • PDF

경골 및 비골 원위부 골육종의 종양삽입물을 이용한 사지구제술 (Limb Salvage with Tumor prosthesis for Osteosarcoma of Distal Tibia and Fibula)

  • 이한구;이상훈;김동준
    • 대한골관절종양학회지
    • /
    • 제1권1호
    • /
    • pp.23-29
    • /
    • 1995
  • Recently limb-salvage operation is widely used for the treatment of malignant bone tumor. But distal leg is out of range of limb-salvage operation due to its technical problem. We report satisfactory limb-salvage operation with tumor prosthesis in 3 cases of osteosarcoma of the distal tibia and fibula. Two cases involved in the tibia and 1 case in the fibula. Average age at operation was 23 years. Neoadjuvant and adjuvant chemotherapy were performed in all 3 cases. We used custom made tumor prosthesis which is designed by Seoul National University Orthopaedic Department. Overall Functional Evaluations by Enneking rating system were good in all 3 cases. All cases are CDF(continuosly disease free since the surgical procedure) state at mean follow-up 2 year and 9 months. In conclusion limb-salvage with tumor prosthesis is useful treatment modality for malignant bone tumor of distal tibia and fibula. Good functional results and few complications suggests limb salvage of distal lower leg may be replaceable with B-K amputation.

  • PDF

몰입감 있는 맞춤형 가상 모델하우스 (Immersive Virtual Custom-made Model House)

  • 황선욱;김영미;서용원;고광희;류제하;이관행;이용구
    • 한국CDE학회논문집
    • /
    • 제13권1호
    • /
    • pp.8-17
    • /
    • 2008
  • Putting a high value on individual preferences is a modern trend that more and more companies are considering for their product design and development and the apartment design is not an exception. Most apartments today are built using similar design with no room for customization. People in general want their tastes to be reflected in the design of their apartment. However, delivering what customers like to the construction company may not be an easy task in practice. For this reason, an intuitive and effective medium between the company and customers for effective communication is needed to ameliorate such a difficulty and in response to this necessity, we developed a test platform for the virtual model house which provides a user with the customization of the apartment using haptic interactions. In our virtual environment, a user can explore an apartment and change the interior based on their taste and feel through intuitive haptic interactions.

2.45GHz 마이크로파 무선데이터 인식 시스템 개발 (Development of 2.45GHz Microwave Identification System)

  • 윤동기;박양하;김관호;이영철
    • 한국통신학회논문지
    • /
    • 제24권7B호
    • /
    • pp.1342-1350
    • /
    • 1999
  • 본 논문에서는 2.45GHz 비접촉식 마이크로파 무선인식시스템을 개발하고 특성을 분석하였다. 응답기와 질문기 사이에 9,600bps 전송속도로 데이터 인식을 통하여 통신절차와 에러검출 보정방식 및 송.수신회로 범용소자를 이용하여 설계.제작하였고, 송.수신안테나와 응답기 전원제어를 위한 제어 프로토콜을 추가하여 시스템의 신뢰성을 향상시켰다. 실험결과, 응답기는 3.6V의 전원 공급시 15$\mu\textrm{A}$의 저전류 소모를 보였으며 최대, 80km/h의 이동속도에 대한 데이터 전송 성공률은 초대 인식거리 10m에서 90%이상의 결과를 얻었다.

  • PDF

인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향 (Effect of Eversion Characteristics on Knee and Ankle Joint of Trans-tibial Amputees)

  • 배태수;장윤희;김신기;문무성
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.886-891
    • /
    • 2009
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

A Giant Pseudo-Aneurysm on the Anastomosis Site for a Redo Bentall Operation due to Behçet Disease Treated by Thoracic Endovascular Aortic Aneurysm Repair with a Custom-Made Stent Graft

  • Won, Jongyun;Jung, Jae Seung;Lee, Jun Hee;Jung, Young Ki;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • 제53권6호
    • /
    • pp.411-413
    • /
    • 2020
  • A 34-year-old man who had undergone aortic valve replacement 8 years ago underwent an additional Bentall operation due to mechanical valve dehiscence 2 years later. Subsequently, he was diagnosed with Behçet disease and Batter syndrome. A week after being hospitalized again due to chest pain and dyspnea, a large pseudo-aneurysm was detected on computed tomography. Because of the excessively large size of the pseudo-aneurysm, surgical treatment seemed very risky. Therefore, we planned to perform thoracic endovascular aortic repair (TEVAR) and treated him successfully. However, the patient experienced recurrence of the same symptoms 4 months later, and was found to have type IV endoleak. He received a TEVAR procedure again, and it was successful.

임베디드 서모커플 센서 제조 및 미끄럼 마찰 계면온도 측정에 관한 실험적 연구 (Fabrication of Embedded Thermocouple Sensor and Experimental Study on Measurement of Interface Temperature for Dry Friction)

  • 장범택;임영헌;김석삼
    • Tribology and Lubricants
    • /
    • 제29권6호
    • /
    • pp.372-377
    • /
    • 2013
  • This study investigated the interface temperatures for the sliding friction of three types of pins fabricated with thermocouple wires by the suction casting method. Optical microscopy was used to examine the surrounding material state at the bonding interface with the thermocouple wires. Friction tests were performed under dry sliding conditions against stainless steel 304 at nominal stresses of 1.42-4.25 MPa and sliding speeds of 0.5-1.25 m/s. Tribological data were collected using a custom-made pin-on-disk apparatus that measured the interface temperature and corresponding friction coefficient. Static tests were performed to demonstrate the functionality and reliability of the thermocouple wires-combined temperature sensor (TCTS). Each TCTS showed good linearity and sensitivity and very similar response times for the thermocouple and critical temperature during sliding friction.