• Title/Summary/Keyword: cushion

Search Result 363, Processing Time 0.026 seconds

Development of a hip model for impact testing of bedsore prevention cushions (욕창예방 방석의 충격시험용 둔부 모형 개발)

  • JUNG, SUNGBAE;YUK, SUNWOO;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.7-11
    • /
    • 2024
  • The bedsore prevention cushion serves to prevent the skin on the buttocks of a wheelchair user from being damaged through friction with the wheelchair seat. This is because it absorbs some of the weight applied to the wheelchair seat and allows the weight to be applied evenly to the entire contact surface. For the impact test, which is part of the performance testing of bedsore prevention cushions, a hip model that represents the sitting posture of a wheelchair user is required. In this study, a hip model was manufactured for impact testing of bedsore prevention cushions for wheelchairs. Performance tests for pressure bedsore prevention cushions for wheelchairs include KSP 0236, a Korean standard, and KS P ISO 16840-2, an ISO international standard. The hip model proposed in KS P ISO 16840-2 was more suitable for impact testing of bedsore prevention cushions for wheelchairs. However, the guidelines for making hip models proposed by international standards need to be modified to reflect the advancement of model making technology and use easier methods. We propose a new hip model production method that produces a hip model out of plastic all at once and additionally attaches SS-41 steel plates processed into the shape of the hip to make the mass of the model similar to the human body.

동중국해 대륙붕 상에서 형성된 Cold Cushion의 시공간적 변동

  • 서영상;이용화;오현주;장이현;황재동;김복기
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.227-228
    • /
    • 2001
  • 배타적 경제수역(EEZ) 설정으로 인하여 한국 연근해 뿐만 아니라 공해 공동어장으로서 중요한 동중국해에서도 지속적인 생산성 유지를 위한 수산자원의 효율적 이용 및 관리가 요구되어, 이 해역에 대한 과학적 해양조사를 통해 해황의 시공간적 변동 특성을 적시에 구명해야 할 시기에 와 있다. 동중국해 북부해역은 대부분 대륙붕으로 구성되어 있다. (중략)

  • PDF

Apparatus for massaging of the principle ni,n of the human body in cushion for chair (노화방지용 좌욕기 장치개발)

  • 박노국
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.05a
    • /
    • pp.143-147
    • /
    • 2003
  • This study is to develop a device of bath-seat with massage which is attached to bath-seat and is able to sustain massage on perineal region and anus effectively. And also develop new programmed driving-seat that is able to protect drowsiness. This seat is operated easily by user controlling time period (eg. 30 minutes or 60 minutes) of vibration. During the vibration, user can make a choice of making n sound which is proved as a better effects for concentration and comfort.

  • PDF

Implementation of Cushion Type Posture Discrimination System Using FSR Sensor Array (FSR 센서 어레이를 이용한 방석형 자세 판별시스템의 구현)

  • Kim, Mi-Seong;Seo, Ji-Yun;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.99-104
    • /
    • 2019
  • Recently, modern people are increasing the incidence of various musculoskeletal diseases due to wrong posture. Prevention is possible through proper posture habit, but it is not easy to recognize posture by oneself. Various studies have been conducted to monitor persistent posture in daily life, but most studies using constrained measurement methods and high-cost measurement equipment are not suitable for daily life. In this paper, we implemented a posture discrimination system using a FSR sensor array that can induce posture correction spontaneously through sitting posture monitoring in daily life. The implemented system is designed as a cushion type so it is easy to apply to existing chair. In addition, it can identify five most common postures in everyday life, and can monitor real-time through Android-based smart-phone monitoring application. For the performance evaluation of the implemented system, each posture was measured 50 times repeatedly. As a result, 97.6% accuracy was confirmed.

The Influence of Unstability of Supporting Surface on Trunk and Lower Extremity Muscle Activities During Bridging Exercise Combined With Core-Stabilization Exercise (중심 안정성 운동을 적용한 교각운동 시 지지면 불안정성이 체간 및 하지의 근 활성도에 미치는 영향)

  • Lee, Sim-Chul;Kim, Tack-Hoon;Cynn, Heon-Seock;Roh, Jung-Suk
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.17-25
    • /
    • 2010
  • The aim of this study was to investigate the effect of supporting surface instability to trunk and lower extremity muscle activities during bridging exercise combined with core-stabilization exercise. Thirty young healthy adults (15 males and 15 females) voluntarily participated in this study. Each subject was asked to perform bridging exercise combined with core-stabilization exercise on three different supporting surfaces (stable ground surface, the wooden balancing board, and the air cushion). The muscle activities were measured using surface electromyography (EMG) during performing exercise. To test statistical significance, one-way ANOVA with repeated measures was used with the significance level of .05. The findings of this study are summarized as follows. (1) There were significant differences in muscle activities on internal oblique, external oblique, gluteus medius, semitendinosus, biceps femoris, medial gastrocnemius and lateral gastrocnemius during exercise (p<.05). (2) The biceps femoris and lateral gastrocnemius showed significantly higher muscle activity on the wooden balancing board rather than on the ground, and semitendinosus, biceps femoris, medial gastrocnemius and lateral gastrocnemius showed significantly higher muscle activity on the air cushion rather than on the ground (p<.05). Therefore, it is concluded that muscle activities in the trunk and the lower limbs during bridging exercise combined with core-stabilization exercise was affected with instability of supporting surface. Further researches are needed to investigate the long term effect of bridging exercise on muscle activity with patient group.

A Study on Noxious Gases Analysis of Polyurethane foams (Polyurethane foam의 유해가스 분석에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.7-13
    • /
    • 2000
  • We had investigated thermal stability, Ignition temperature and fire gas for polyurethane foams used for manikin, cushion and interior finishing material. Decomposition of polyurethane foams with temperature was investigated using a DSC and the weight loss with temperature increase using a TGA in order to find the thermal hazard of polyurethane foams, and the ignition temperature of polyurethane foams according to species. We studied constant temperature among ignition temperature measuring methods. In addition, noxious gases for polyurethane foams according to combustion condition were analyzed using gas analyzer and GASTEC. As results, initial decomposition temperature of polyurethane foam used for interior finishing material was lower than those for manikin and cushion, and exothermic energy was higher. Ignition temperature of polyurethane foam of interior finishing material was $420^{\circ}$. All of combustion forms at $427^{\circ}$ and under were smoldering combustion, and it was combustion at $500^{\circ}$. As furnace temperature was increased, concentration of noxious gases such as carbon oxide, carbon dioxide, and hydrogen cyanide was increased. And nitrogen oxide at combustion condition($500^{\circ}$) was over 10 ppm.

  • PDF

Automotive Airbag Inflator Analysis Using Measured Properties of Modern Propellants (추진제 특성을 이용한 에어백 인플레이터 성능 제어에 대한 실험 및 해석에 대한 연구)

  • Seo, Young-Duk;Kim, Gun-Woo;Hong, Bum-Suk;Kim, Jin-Ho;Chung, Suk-Ho;Yoh, Jai-Ick
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.53-62
    • /
    • 2010
  • An airbag is composed of housing assembly, door assembly, cushion assembly, and an inflator. The inflator is the essential part that generates gas for airbag. When an airbag is activated, it effectively absorbs the crash energy of the passenger by inflating a cushion. In this study, tank tests were performed with newly synthesized propellants with various compositions, and the results are compared with the numerical results. In the simulation of inflator, a zonal model has been adopted which consisted of four zones of flow regions: combustion chamber, filter, gas plenum, and discharge tank. Each zone was described by the conservation equations with specified constitutive relations for gas. The pressure and temperature of each zone of the inflator were calculated and analyzed and the results were compared with the tank test data. In the zone of discharge tank the pressure quickly rose, the pattern of pressure curve was very similar to the pressure curve of real test. And in zone 1 & 2 & 3 the mass of products was increased and decreased with time. In zone 4, the mass of products was increased with time like real inflator. From the similarity of pressure curve in zone 4 and closed bomb calculation the modeled results are well correlated with the experimental values.

Reliability and Validity of the Measurement of Pelvic Movement in Low Back Pain Patients using Cushion Sensor in Sitting Position (앉은 자세에서 방석센서를 이용한 요통환자 골반가동성 측정의 신뢰도와 타당도)

  • Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2020
  • PURPOSE: Postural and structural asymmetry due to muscle imbalances around the lower back and pelvis are the causes of back pain. Muscle imbalances in patients with chronic low back pain affect the pelvic tilt and movement, and it is necessary to assess the pelvic movement ability using the appropriate tools to determine the mediating effects of lower back pain. This paper reports the reliability and validity of the Sensbalance Therapy Cushion (STC) for pelvic movement and proprioception. METHODS: In this study, the Wii balance board (WBB) was used as a golden standard for pelvic movement measurements. FABQ, KODI, Myovision, and Pelvic movement were measured in 50 patients with chronic low back pain. The correlation between the lower-back muscle activity and pelvic movement was checked. The pelvic movement parameter was measured twice to determine the intra-rater reliability. RESULTS: The STC showed high test-retest reliability in the pelvic tilt measurements (ICC = .672 - .809). The test-retest reliability of proprioception measurements (ICC = .588 - .859) and reaction time measurements (ICC = .542 - .836) were also high. The relationship between the WBB and STC showed a significant positive correlation with the pelvic tilt test (p < .01). The posterior pelvic tilt and lower-back muscle activity showed a significant negative correlation (p < .01). The pelvic left tilt and lower-back muscle activity showed a significant negative correlation (p < .05). CONCLUSION: The results revealed the high reliability and validity of the STC. Therefore, the STC can be used as an objective measuring device for evaluating pelvic tilt, proprioception, and reaction time in low back pain patients.

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.