• Title/Summary/Keyword: curvature factor

Search Result 229, Processing Time 0.028 seconds

A study ell the residual stress in rail by the web saw-cut method (복부절단법에 의한 레일의 잔류응력에 관한 연구)

  • 서정원;구병춘;정우현
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.234-241
    • /
    • 1999
  • Rails have residual stresses produced during manufacturing processes. The residual stresses play all important role on brittle fracture, fatigue strength and derailment by producing cracks in the web of rail. The web saw-cut test is a technique developed to measure the bulk longitudinal residual stress level. It is a simple mettled to estimate a stress intensity factor, $_{4}$ for a web crack by using the radii of curvature of the upper and lower portions of a cut rail. But according to this method, $_{4}$ varies along the rail length because the curvatures along tile rail length vary In this paper, tile residual stress was estimated by Finite Element Method and tile web saw-cut method. In addition tile variation of the residual stress with time was investigated.

  • PDF

A Study on Running Resistance of Rolling Stock (철도차량의 주행저항에 관한 연구)

  • Kim, Eung-Cheon;Lee, Jae-An;Lee, Ha-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1782-1793
    • /
    • 2008
  • Republic of korea has begun operating high speed train service according as KTX service operation starts in 2004. Also, EMU whose maximum speed is over 150 kph will be starting to service with electrification and improvement of existing railroad. Moreover, metropolitan electric railways have begun an express service to increase scheduled speed. Therefore, running resistance of rolling stock becomes more important factor effects on the performance. Running resistance of rolling stock is the factor which is necessary for the performance or operation plan of rolling stock, and it's related to rolling friction, slip friction, drag force, gradient, acceleration, curvature, tunnel condition and so on. It is possible to be calculated by CFD (Computational Fluid Dynamics). However it is predicted by experimental equation from running resistance test because of the complex calculation and manifold variables. In this paper, studies about running resistance of rolling stock is introduced, and each term of experimental equation is studied through theoretical approximation. Also, running resistance of rolling stock is estimated by the result of running resistance test, and effects being related to friction, drag force, gradient is examined.

  • PDF

A Study on the Somatotype of the Upper Body for the Women's Bodice Pattern (길 원형을 위한 상반신의 체형 연구 - 한국 성인 여성을 대상으로 -)

  • Lee Soon Won;Nam Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.4 s.40
    • /
    • pp.341-349
    • /
    • 1991
  • This study was done to provide basic data for clothing design and thus to contribute to the academic development of the clothing and textile area. The focus of this study was to charac­terize the somatotype based on each individual's lateral view. For this purpose, firstly, categorization of the subjects based on their lateral view and definition of each category, secondly, characterization of each somatotype, and thirdly, sugges­tion of the deterministic criteria of each category were complished. The subjects in this study were female college students of 18 to 26 year-old whose somatotypes were comparatively invariable after cessation of physical growth. The metrical items characterizing upper body lateral view were chosen. Data were collected through Anthropometry and Photometry and analyzed by Factor analysis. The results were as follows; 1. Each subject's side view contour was classified as straight type, lean-back type, bend­forward type, and swayback according to its position to the relative plumb line. Straight type was defined as the type in which the plumb line passes through the lobe of the ear, the shoulder joint, and the mid abdominal region laterally. Lean-back type positioned the plumb line more posteriorly than straight type. Bend-forward type positioned the plumb line more anteriorly than straight type. Swayback positioned the plumb line at about the same line as straight type. And curvature of side view contur was more prominent in this type than in straight type. 2. Seven factors were figured out. The first factor was representing upperbody volume, and the second factor was representing size, the third factor was horizontal distance from lateral view representing size view contour. The fourth factor was front body length, the fifth factor was back body length. The sixth factor was shoulder length and shoulder width representing shoulder shape. The seventh factor was the bust shape.

  • PDF

Re-evaluated Overstrength Factor for Capacity Design of Reinforced Concrete Bridge Columns (철근콘크리트 기둥의 성능설계를 위한 모멘트 초과강도계수에 관한 연구)

  • Lee, Jae-Hoon;Choi, Jin-Ho;Ko, Seong-Hyun;Kwon, Soon-Hong
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.308-315
    • /
    • 2005
  • The capacity protection is normally related with slenderness effect of the columns, force transfer in connections between columns and adjacent elements, and shear design of columns. It is intends to prevent brittle failure of the structural components of bridges, so that the whole bridge system may show ductile behavior and failure during earthquake events. For bridge systems, this means it is necessary to assess the overstrength capacity of columns prior to proceeding with the design of foundation and superstructure. The objective of this paper is to develop a capacity design approach that applies an overstrength factor for determination of possible maximum shear force in the plastic hinge zone of reinforced concrete bridge columns. In order to estimate and determine overstrength factor, material strength was developed to investigate for actual material strength total 3,407 steel and 5,405 concrete by domestic product. Based on actual material strength, this paper was conducted on moment overstrength factors using moment-curvature analysis program. And also design recommendations for capacity design are presented to revise the annual report, KEERC 2002.

  • PDF

The Development of a Checklist for Quantitative Assessment of Risk Factors of Musculoskeletal Complaints in Shipbuilding Workers (조선소 근로자의 근골격계 자각증상에 대한 위험요인 평가척도 개발)

  • Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.16 no.1
    • /
    • pp.42-51
    • /
    • 2009
  • The purpose of this study was to develop a checklist of risk factors for quantitative assessment of musculoskeletal complaints in shipbuilding workers. A key point was to develop comprehensive a checklist including the worker's physical ability, as ergonomic and workload factors. ln the first, through correlation analysis between musculoskeletal complaints and physical abilities in shipbuilding workers, risk factors related to physical abilities were selected. In the second, after the development of a checklist was composed of physical, ergonomic and workload factors, factor analysis was used to test the validity of the developed checklist. Each factors selected finally showed that physical factors were hand grip strength, spinal curvature, and flexibility (sit to reach), ergonomic factors were posture, total exposed time, duration, and force of working, and workload factors were physical and psychological workload perceived by worker. The results showed that musculoskeletal complaints was associated with physical abilities (p<.05). The developed checklist had a reliability of .761 (Cronbach=.761) and a validity and explanation of 54.9%. The criterion of management was classified in 4 stages by relative weights of each factor. It is suggested that active intervention is needed to reduce musculoskeletal complaints in workers with more than a 14.31 score.

  • PDF

Path Loss Characteristics in Subway Tunnel at 2.65GHz (지하철 터널 환경에서 2.65GHz 대역신호의 경로손실 특성)

  • Jo, Han-Shin;Kim, Do-Youn;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1014-1019
    • /
    • 2006
  • The research deals with the measurement of electromagnetic wave propagation in subway tunnels at 2.65GHz. Measurements have been conducted in 4 different types of tunnel courses, a straight tunnel, two curved tunnels, with 245m and 500m radius of curvature, and a tunnel that has both straight and curved sections. we found that the path loss exponent for the line-of-sight(LOS) region inside all the tunnels is $1.31{\sim}2.19$. The path loss exponents for LOS regions in the tunnel is lower than $(3{\sim}4)$, which corresponds to the path loss exponent factor for outdoor cellular environments. The path loss exponents of the straight tunnel, two curved tunnels with 245m and 500m radius of curvature are 1.94, 2.92, and 4.34, respectively. This indicates that a smaller radius of curvature in tunnel results in a higher path loss exponent for nonline-of-sight(NLOS) region. The path loss exponents for the NLOS region in the combined and curved tunnel, which have the same radii of cuvature, are 5.88 and 4.34, respectively. Therefore, it can be concluded that the path loss characteristics in tunnel environments are infulenced by the radii of curvature as well as the LOS distance.

A Study on the Response Modification Factor for a 5-Story Reinforced Concrete IMRF (5층 철근콘크리트 중간모멘트골조의 반응수정계수에 관한 연구)

  • Kang, Suk-Bong;Lim, Byeong-Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.13-21
    • /
    • 2012
  • In this study, the response modification factor for a RC IMRF is evaluated via pushover analysis, where 5-story structures were designed in accordance with KBC2009. The bending moment-curvature relationship for beams and columns was identified with a fiber model, and the bending moment-rotation relationship for beam-column joints was calculated using a simple and unified joint shear behavior model and the moment equilibrium relationship for the joint. The results of the pushover analysis showed that the strength of the structure was overestimated with negligence of the inelastic shear behavior of the beam-column joint, and that the average response modification factor for category C was 7.78 and the factor for category D was 3.64.

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

Effects of Transverse Reinforcement on Strength and Ductility of High-Strength Concrete Columns

  • Hwang, Sun Kyoung;Lim, Byung Hoon;Kim, Chang Gyo;Yun, Hyun Do;Park, Wan Shin
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.39-48
    • /
    • 2005
  • Main objective of this research is to evaluate performance of high-strength concrete (HSC) columns for ductility and strength. Eight one-third scale columns with compressive strength of 69 MPa were subjected to a constant axial load corresponding to 30 % of the column axial load capacity and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (${\rho}_s=1.58$, 2.25 %), tie configuration (Type H, Type C and Type D) and tie yield strength ($f_{yh}=549$ and 779 MPa). Test results show that the flexural strength of every column exceeds the calculated flexural capacity based on the equivalent concrete stress block used in the current design code. Columns with 42 % higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour, showing a displacement ductility factor (${\mu}_{{\Delta}u}$) of 3.69 to 4.85, and a curvature ductility factor (${\mu}_{{\varphi}u}$) of over 10.0. With an axial load of 30 % of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 549 MPa.

PROBABILISTIC LANDSLIDE SUSCEPTIBILITY AND FACTOR EFFECT ANALYSIS

  • LEE SARO;AB TALIB JASMI
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.306-309
    • /
    • 2004
  • The susceptibility of landslides and the effect of landslide-related factors at Penang in Malaysia using the Geographic Information System (GIS) and remote sensing data have been evaluated. Landslide locations were identified in the study area from interpretation of aerial photographs and from field surveys. Topographical and geological data and satellite images were collected, processed, and constructed into a spatial database using GIS and image processing. The factors chosen that influence landslide occurrence were: topographic slope, topographic aspect, topographic curvature and distance from drainage, all from the topographic database; lithology and distance from lineament, taken from the geologic database; land use from Landsat TM (Thermatic Mapper) satellite images; and the vegetation index value from SPOT HRV (High Resolution Visible) satellite images. Landslide hazardous areas were analysed and mapped using the landslide-occurrence factors employing the probability-frequency ratio method. To assess the effect of these factors, each factor was excluded from the analysis, and its effect verified using the landslide location data. As a result, land 'cover had relatively positive effects, and lithology had relatively negative effects on the landslide susceptibility maps in the study area. In addition, the landslide susceptibility maps using the all factors showed the relatively good results.

  • PDF