• Title/Summary/Keyword: current-effect

검색결과 10,222건 처리시간 0.036초

한국 남동해안의 용승과 관련된 물리환경 (Physical Envirionment Associated with Upwelling off the Southeast Coast of Korea)

  • 이재철;김대현
    • 한국수산과학회지
    • /
    • 제51권5호
    • /
    • pp.579-589
    • /
    • 2018
  • Data from the two bottom moorings of ADCP (acoustic doppler current profiler), coastal weather station and CTC (conductivity temperature depth) observations for 2001 were analyzed to describe the physical processes associated with upwelling off the southeast coast of Korea. Winds were favorable for upwelling during summer, but were not correlated with currents. Shoaling of isotherms toward the coast due to the baroclinic tilting of the strong East Korean Warm Current (EKWC) provided a favorable background for immediate upwelling-response of surface temperature to southerly winds. This baroclinic effect was supported by a significant inverse coherence between the upper-layer current and bottom temperature near the coast. This upwelling is similar to the Guinea Current upwelling, which is driven by remote forcing (Houghton, 1989). Persistent southward flow was observed below approximately $10^{\circ}C$ isotherm throughout the observation period.

EPR의 전기특성에 미치는 방사선의 영향 (Effect of the Co$^{60}$ -Rays due to Electric properties of EPR-)

  • 이성일
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 추계학술대회
    • /
    • pp.253-259
    • /
    • 2002
  • The value of charge currnet, discharge current, ${\varepsilon}r^'$,${\varepsilon}r^{'}$ residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated C0$^{60}$$\gamma$ ray 0~38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by C0$^{60}$-$\gamma$- irradiation dose. The charging current and the discharging current of EPR increas, depending on the ratio of degradation. As the irradiatin dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful C0$^{60}$$\gamma$- irradiation dose. The increase of peak in ${\varepsilon}r^{'}$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

Pulsed-GMAW의 금속 이행 현상에 관한 동적 해석 (Dynamic Analysis of Metal Transfer in Pulsed-GMAW)

  • 최상균;유중돈;박상규
    • Journal of Welding and Joining
    • /
    • 제15권5호
    • /
    • pp.84-91
    • /
    • 1997
  • The metal transfer phenomenon of the pulsed-GMAW is simulated by formulating the electromagnetic force incorporated with the Volume of Fluid algorithm. The free surface profiles, pressure and velocity distributions within the drop are computed numerically. Axial velocity and acceleration generated during peak current period are found to have a significant effect on drop detachment. Therefore, the accelerated inertia force becomes one of important factors affecting metal transfer in the pulsed-GMAW. When the pulse current parameters are selected properly, the molten drop is detached just after current pulse, and the operating range of the pulsing frequency increases with higher peak current and duty cycle. Calculated operating ranges show reasonably good agreements with the available experimental data.

  • PDF

The Effect of Deformation Stress-strain and Temperature on the $I_c$ Degradation of Bi-2223/Ag Tapes

  • Ha, Hong-Soo;Kim, Sang-Cheol;Ha, Dong-Woo;Oh, Sang-Soo;Joo, Jin-Ho
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1251-1252
    • /
    • 2006
  • In order to investigate 95% retained critical current of Bi-2223/Ag tapes under various stress-strain conditions, load cell attached tension and bending apparatus was used. The critical current of stress-strained tape was degraded below 95% retained critical current when tension and bending was simultaneously applied together. But only one of this tension or bending did not degrade the tape below 95% retained critical current. Deformation temperature was important to maintain the 95% retained Ic of Bi-2223/Ag tapes after bending or tension deformation because mechanical strength of tapes can be changed drastically between room temperature and 77 K.

  • PDF

Effect of Processing Factors on Critical Current Density in Bi2212/Ag Wires

  • Kim, Sang-Cheol;Ha, Dong-Woo;Oh, Sang-Soo;Han, Il-Yong;Ha, Hong-Soo;Sohn, Ho-Sang
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1243-1244
    • /
    • 2006
  • Five kinds of double stacked 385 (55 x7) filamentary Bi2212/Ag round wires and 55 filamentary tapes with different Ag ratios (silver area/superconductor area) have been fabricated via PIT method, and the effects of Ag ratio and processing factors on critical current density were studied. The effects of the maximum temperature and average filament diameter on critical current density were also studied. The wire of 0.74 mm diameter having Ag ratio 3.7 showed critical current density of $2,218\;A/mm^2$ at 4.2 K, 0 T.

  • PDF

실온 펄스도금법을 이용한 STS 316L 표면의 Ni 도금 저가형욕 연구 (Study of Ni-coating on 316L Stainless Steel by Pulse Electroplating in Various Bath Conditions at Room Temperature)

  • 정세진;조계현
    • 한국표면공학회지
    • /
    • 제35권1호
    • /
    • pp.53-63
    • /
    • 2002
  • Ni coating was carried out by pulse plating at room temperature. So, experimental conditions for Ni-coating were based on Watt's bath, and new additives(propionic acid) were introduced in the Watt's bath electrolyte as $H_3$$BO_3$ alternatives. By adding propionic acid, coating layer demonstrated a good adhesion and uniformity without special pre-treatment of the 316L stainless steel at room temperature. With a decrease of amount of propionic acid and applied average current density, cathode current efficiency increased. Also, edge effect was decreased with decreasing a peak current and increasing a pulse frequency in the same bath condition. It was found that the optimum condition for Ni coating was a current density of 10~20mA/$\textrm{cm}^2$ at below 500 mA peak current in the $5m\ell/\ell$ propionic acid solution.

직류 및 교류스트레스 조건에서 발생된 Hot-Carrier가 PMOSFET의 누설전류에 미치는 영향 (Hot-Carrier Induced GIDL Characteristics of PMOSFETs under DC and Dynamic Stress)

  • 류동렬;이상돈;박종태;김봉렬
    • 전자공학회논문지A
    • /
    • 제30A권12호
    • /
    • pp.77-87
    • /
    • 1993
  • PMOSFETs were studied on the effect of Hot-Carrier induced drain leakage current (Gate-Induced-Drain-Leakage). The result turned out that change in Vgl(drain voltage where 1pA/$\mu$m of drain leadage current flows) was largest in the Channel-Hot-Hole(CHH) injection condition and next was in dynamic stress and was smallest in electron trapping (Igmax) condition under various stress conditions. It was analyzed that if electron trapping occurrs in the overlap region of gate and drain(G/D), it reduces GIDL current due to increment of flat-band voltage(Vfb) and if CHH is injected, interface states(Nit) were generated and it increases GIDL current due to band-to-defect-tunneling(BTDT). Especially, under dynamic stress it was confirmed that increase in GIDL current will be high when electron injection was small and CHH injection was large. Therefore as applying to real circuit, low drain voltage GIDL(BTDT) was enhaced as large as CHH Region under various operating voltage, and it will affect the reliablity of the circuit.

  • PDF

전류벡터제어시험법에 의한 IPMSM의 인덕턴스 산정 (The Inductance Computation of IPMSM using Current Vector Control Test)

  • 조규원;이정규;김규탁
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1807-1812
    • /
    • 2012
  • In this paper, the d, q-axis inductance of IPMSM(Interior Permanent Magnet Synchronous Motor) was calculated by the FEA(Finite Element Analysis). And the CVCT(Current Vector Control Test) was performed, and compared with FEA. Therefore the inductance experiment according to the variation of the current phase angle was performed. However, the error was generated in the fundamental wave detection of the voltage and current waveform. So, error has largely effect on the result of computation, it has to note specially. In addition, by using the calculated inductance, the torque calculation was performed and this result was compared through the dynamometer experiment.

개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템 (Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques)

  • 손진근;서일동;전희종
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.

온도측정에 의한 산화아연형 피뢰기 진단 (ZnO Arrester Diagnosis by Measurement of Temperature)

  • 길경석;한주섭;송재용;서황동;문승보;박태곤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.361-364
    • /
    • 2005
  • In this paper, surface temperatures of ZnO arresters as a function of ambient temperatures and leakage currents were experimentally investigated. The variations of the leakage current was below 10 uA, which comes about $4.5\%$ of the normal leakage current. Temperature differences between the ambient and the surface of arresters were not shown until $150\%$ to the normal leakage current, and were remarkable over $200\%$. From the results, we deduced a couple of polynomials which enables the calculation of the leakage current by the measurement of surface temperature. Tests on used arresters have shown the same results as the experimental one. Also, we expect that an arrester diagnosis is possible by measuring the surface temperature of them after more studies on the effect of wind, moisture penetration, and arrester types.