• Title/Summary/Keyword: current-effect

Search Result 10,222, Processing Time 0.038 seconds

The Effect of Micro-current Electrical Therapy on Muscle Atrophy and Delayed Wound Healing Process Induced Rat Caused by Traumatic Peripheral Nerve Injury (외상성 말초신경 손상으로 인한 창상 치유 지연 및 근위축이 유발된 소동물에서의 미세전류 자극 효능 평가)

  • Lee, Hana;Kim, Seohyun;Hwang, Donghyun;Yoo, Lee;Yu, Jihee;Kim, Minju;Cho, Seungkwan;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • This study was carried out to evaluate the effect of micro-current therapy on muscle atrophy and delayed wound healing process caused by traumatic peripheral nerve injury. For this, twenty-five 5-week-old Sprague Dawley rat were used and assigned to five groups including the normal group (NOR, n=5), the wound group (WD, n=5), the wounded and treated with micro-current electrical therapy group (WD+MET, n=5), the sciatic nerve denervated and wounded group (WD+DN, n=5), and the sciatic nerve denervated, wounded and treated with micro-current electrical therapy group (WD+DN+MET, n=5). In order to assess the changes in length of incisional wound for 12 days and the muscle volume for 2 weeks, the ImageJ analysis of macroscopic analysis and micro-CT data were obtained and analyzed. As a result, significant delay in the process in wound healing were observed and micro-current therapy suppress the postponement of healing process. Furthermore, there were significant changes in muscle volume between electrically treated group and non-treated group. These result shows that electrical stimulation may improve the delayed healing process and muscle atrophy at once.

Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate (전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and $24A/m^2$) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, $R_t(=R_c+R_f)$ were calculated and compared to those of the controls ($R_0$), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate ($R_t/R_0$) was carried out and the equation ${\rho}^{0.46}_it=7.0$ was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

A study on the Design of Output 380V DC-DC Converter for LVDC Distribution (LVDC 배전을 위한 출력 380V DC-DC 컨버터 설계에 관한 연구)

  • Kim, Phil-Jung;Yang, Seong-Soo;Oh, Byeong-Yun
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.208-215
    • /
    • 2020
  • In this study, the output 380V direct current DC-DC converter for low-voltage direct current(LVDC) distribution was designed in three types, and the voltage and current characteristics of the three types of DC-DC converter were compared and analyzed through simulation. When the converter was configured using a parallel structure with the power metal-oxide semiconductor field-effect transistor and two current suppression insulated-gate bipolar transistors(IGBTs), the time when the output voltage was stabilized at DC 380V was relatively short with 9ms and the range of output current changes was also between 44.8A and 50.2A, indicating that the width of change was much smaller and the effect of current suppression was greater compared to when IGBT was not applied(68~83A). These results suggest that the proposed DC-DC converter for LVDC distribution is likely to be applied to smart grid construction.

A study on Current-Voltage Relation for Double Gate MOSFET (DGMOSFET의 전류-전압 특성에 관한 연구)

  • Jung, Hak-Kee;Ko, Suk-Woong;Na, Young-Il;Jung, Dong-Su
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.881-883
    • /
    • 2005
  • In case is below length 100nm of gate, various kinds problem can be happened with by threshold voltage change of device, occurrence of leakage current by tunneling because thickness of oxide by 1.5nm low scaling is done and doping concentration is increased. SiO$_2$ dielectric substance can not be used for gate insulator because is expected that tunneling current become 1A/cm$^2$ in 1.5nm thickness low. In this paper, devised double gate MOSFET(DGMOSFET) to decrease effect of leakage current by this tunneling. Therefore, could decrease effect of these leakage current in thickness 1nm low of SiO$_2$ dielectric substance. But, very big gate insulator of permittivity should be developed for develop device of nano scale.

  • PDF

The Effect of Tyrosine Kinase Inhibitors on the L-type Calcium Current in Rat Basilar Smooth Muscle Cells

  • Bai, Guang-Yi;Yang, Tae-Ki;Gwak, Yong-Geun;Kim, Chul-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.215-220
    • /
    • 2006
  • Objective : Tyrosine kinase inhibitors may be useful in the management of cerebral vasospasm. It has not yet been reported whether L-type $Ca^{2+}$ channels playa role in tyrosine kinase inhibitors-induced vascular relaxation of cerebral artery. This study was undertaken to clarify the role of L-type $Ca^{2+}$ channels in tyrosine kinase inhibitors-induced vascular relaxation, and to investigate the effect of tyrosine kinase inhibitors on L-type $Ca^{2+}$ channels currents in freshly isolated smooth muscle cells from rat basilar artery. Methods : The isolation of rat basilar smooth muscle cells was performed by special techniques. The whole cell currents were recorded by whole cell patch clamp technique in freshly isolated smooth muscle cells from rat basilar artery. Results : Patch clamp studies revealed a whole-cell current which resembles the L-type $Ca^{2+}$ current reported by others. The amplitude of this current was decreased by nimodipine and increased by Bay K 8644. Genistein[n=5], tyrphostin A-23[n=3]. A-25[n=6] $30{\mu}M$ reduced the amplitude of the L -type $Ca^{2+}$ channel current in whole cell mode. In contrast, diadzein $30{\mu}M$ [n=3]. inactive analogue of genistein, did not decrease the amplitude of the L-type $Ca^{2+}$ channels current. Conclusion : These results suggest that tyrosine kinase inhibitors such as genistein, tyrphostin A-23, A-25 may relax cerebral vessel through decreasing level of intracellular calcium, [$Ca^{2+}$]i, by inhibition of L-type $Ca^{2+}$ channel.

A Study on the Transformer Design considering the Inrush Current Reduction in the Arc Welding Machine

  • Kim, In-Gun;Liu, Huai-Cong;Cho, Su-Yeon;Lee, Ju
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.374-378
    • /
    • 2016
  • The transformer used in an inverter type arc welding machine is designed to use high frequency in order to reduce its size and cost. Also, selecting core materials that fit frequency is important because core loss increases in a high frequency band. An inrush current can occur in the primary coil of transformer during arc welding and this inrush current can cause IGBT, the switching element, to burn out. The transformer design was carried out in $A_P$ method and amorphous core was used to reduce the size of transformer. In addition, sheet coil was used for primary winding and secondary winding coil considering the skin effect. This paper designed the transformer core with an air gap to prevent IGBT burnout due to the inrush current during welding and proposed the optimum air gap length.

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition

  • Jeong Seung-Gi;Lee Dong-Ki;Park Ki-Won
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.808-815
    • /
    • 2001
  • The three-phase diode rectifier with a capacitive filter is highly sensitive to line voltage unbalance, and may cause significantly unbalanced line currents even under slightly unbalanced voltage condition. This paper presents an analysis of this 'unbalance amplification' effect for an ideal rectifier circuit without ac-and dc-side inductors. The voltage unbalance is modeled by introducing a deviation voltage superimposed on balanced three-phase line voltages. With proper approximations, closed-form expressions for symmetrical components of the line current and current unbalance factor are derived in terms of the voltage unbalance factor, filter reactance, and load current. The validity of analytical predictions is confirmed by simulation.

  • PDF

The effect electrolysis conditiong on the composition and the preferred orientation of Co-Fe-Cr alloy electrodeposits (Co-Fe-Cr 합금도금층의 조성 및 우선방위에 미치는 전해조건의 영향)

  • 예길촌;문근호
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.6
    • /
    • pp.393-399
    • /
    • 1998
  • The composition and the properred orientation of Co-Fe-Cr alloy electrodeposits were invesigated according to the electrolysis conditions using sulface bath. The current efficiency and the cathode overpotential decrased noticeably with the increase of Cr content in the bath. As the D.C. current density increased increased, the Cr content in the alloy increasd, while Co content decreased and Fe content remained constant, In the pulse current electrolysis, the Cr content of the alloy increased with the mean current density and off-time and then its content increased mord more noticeably with the peak current density than that of D.C. electrolysis. The preferred orientation of the alloy changed from (220)+(111) to (220) with decreasing cathode overpotential.

  • PDF

Characteristics of Parallel Winding Drive of SRM (SRM의 병렬권선 운전 특성)

  • Hwang, Hyung-Jin;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.66-68
    • /
    • 2003
  • In a motor drive, the current rating is directly related to the rating of a switching device, and the parallel switching operation for a cost reduction is the alternatives because it has the smaller current rating through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. This paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. The proposed strategy is verified by theoretical and experimental verification.

  • PDF

A Study on the Effects of Neutral Current by Unbalanced Load in Two Step Type Pole using KEPCO's Distribution System (한전 배전 계통을 이용한 2단장주의 불평형 부하에 따른 중성선 전류의 영향에 관한 연구)

  • Park, K.W.;Seo, H.C.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Lee, W.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.465-471
    • /
    • 2007
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current increases in three-phase four-wire distribution system due to unbalanced load. Usually, power line and communication line are installed at contiguity by effect of topography in Korea. To this end, the damages such as electrostatic induction, electromagnetic induction and harmonic induction generated by induced voltage and current are occured in power line and communication line. This paper calculates the neutral current in KEPCO's distribution system using EMTP by composing various simulated conditions. Also, these results are verified by vector analysis.