• Title/Summary/Keyword: current-effect

검색결과 10,222건 처리시간 0.032초

고온초전도 PIT선재의 반복 열응력 및 변형률 의존성 (Dependence of thermal cycling and axial strain on HTS PIT tapes)

  • 하홍수;이동훈;최정규;양주생;황선역;김상철;하동우;오상수;권영길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.131-133
    • /
    • 2003
  • The effect of axial strain and thermal cycling on the critical current is investigated for the Bi-2223/Ag PIT tapes. The axial strain was applied to the tapes by the U-shape sample holder. Two kinds of Bi-2223/Ag tapes with different Ag sheath are used to know the effect of sheath alloying for the tensile strain. The influence of thermal cycling between room temperature and 77 K on critical current are examined. Critical current is drastically decreased for Ag/alloy and Ag/alloy/alloy sheathed tapes at tensile strain above 0.22% and 0.3%, respectively.

  • PDF

광폭 전기집진기의 집진특성에 판한 연구 - II. 펄스 하전 파형의 영향 - (A Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator -II. Effect of Wave Form of Pulse Energization -)

  • 김용진;하병길;정상현;홍원석;하대홍;유주식
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study Investigates the effect of the wave form of pulse energization on the collection characteristics of a wide plate spacing electrostatic precipitator. For the semi-pulse energization, the peak current and voltage of the energization increases with increase of the pulse period, and the corona current increases, as pulse ratio decreases. For the micro-pulse energization, the corona current increases with increase of the pulse voltage. The collection efficiency of semi-pulse and micro-pulse energization is larger than that of DC charge.

  • PDF

Comparative Study of Field-Oriented Control in Different Coordinate Systems for DTP-PMSM

  • Zhang, Ping;Zhang, Wei;Shen, Xiaofeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.330-335
    • /
    • 2013
  • This paper performs two kinds of Field-Oriented Control (FOC) for dual three phase permanent magnet synchronous motor (DTP-PMSM).The first is based on vector space decomposition to study the effect of current harmonics on electromechanical energy conversion. And the second presents the coupling relations between two sets of windings using two d-q transformation. And then this paper has deeply studied the differences between these two strategies, the different effect on the control of harmonic current and the reason for these differences. MATLAB-based Simulation studies of a 3KW DTP-PMSM are carried out to verify the analysis of differences between the two FOC strategies.

고전압 전기 자극의 부종 감소 효과 (Effect of High Voltage Pulsed Current on Edema Reduction)

  • 김연정;김철용;홍주완;안덕현
    • 한국전문물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.61-66
    • /
    • 1994
  • The purpose of this study was to investigate the effect of a single treatment o voltage pulsed current (HVPC) on edema reduction. Hind limbs of 23 anesthetized were injured by dropping a 400 g weight onto the plantar aspects of the feet. On limb of each frog was randomly selected to receive 30 minutes of continuous, 12 cathodal HVPC at voltages 10 % less than motor threshold levels. Limb volumes measured by water displacement before trauma and at predetermined intervals hours posttrauma. Sources of significant differences were determined by t-test HVPC significantly (p<0.05) reduced edema formation. We hypothesize that HVP also be effective in controlling edema formation after impact injuries in humans.

  • PDF

외부전원법을 적용한 철근콘크리트의 방식효과 (The Method Effect of Reinforced Concrete by Applying Impressed Current Cathodic Protection)

  • 이해승;조규환;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.60-61
    • /
    • 2013
  • For reinforced concrete structures located in a sea environment, the Impressed Current Cathodic Protection (ICCP) is mostly used as a signature method to prevent steel corrosion. For this research, specimens to which the ICCP is applied were manufactured under the assumption of two following cases the specimens are exposed to various salt damage environments (submerged zone, tidal zone), and deteriorative factors (crack) occur in concrete. For the specimens manufactured, an enhancement experiment for deterioration was conducted through regular cycle change under the temperature between 15 ~ 70℃ with 70 ~ 90% humidity. Afterwards, the method effect was verified through a half-cell method and application of the ICCP derived from salt damage environments was investigated.

  • PDF

진공차단기 스위칭 써지 특성 해석 및 저감 방안 (Surge Characteristics Analysis and Reduction Method of Vacuum Circuit Breaker)

  • 김종겸
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.190-195
    • /
    • 2013
  • Vacuum circuit breaker(VCB) has been widely used for interruption of load current and fault current for high voltage motor in the industrial field. Its arc extinguishing capability is excellent compared to other breakers. But it has the potential to cause multi reignition surge by high extinguishing capability. Surge voltage is generated by the opening and closing of VCB. Multi reignition surge of VCB is steep-fronted waveform. It may have a detrimental effect on the motor winding insulation. So, most of users install a protection device to limit steep-front waveform at the motor terminal or breaker side. So, most of users install a protection device at the motor terminal or breaker side. This protective device is surge absorber(SA) such as ZnO and RC type. In this study, we analyzed whether there is any effect when two type SA is applied to the VCB multi reignition surge. We confirmed that ZnO SA is slightly more effective than RC SA for reduction of multi reignition surge.

이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향- (A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity -)

  • 김용진;하병길;정상현;문상철;유주식
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.

Orthotropic magneto-thermoelastic solid with multi-dual-phase-lag model and hall current

  • Lata, Parveen;Himanshi, Himanshi
    • Coupled systems mechanics
    • /
    • 제10권2호
    • /
    • pp.103-121
    • /
    • 2021
  • The present research deals with the investigation of the effect of hall current in an orthotropic magneto-thermoelastic medium with two temperature in the context of multi-phase-lag heat transfer due to thermomechanical sources. The bounding surface is subjected to linearly distributed and concentrated loads(mechanical and thermal source).Laplace and Fourier transform techniques are used to solve the problem. The expressions for displacement components,stress components and conductive temperature are derived in transformed domain and furtherin physical domain with the help of numerical inversion techniques. The effect ofrotation and hall parameter hasshown with the help of graphs.

서안경계류 역학을 이해하기 위한 실험 장치 및 방법 개발 (Development of Apparatus and Methods for Understanding the Dynamics of the Western Boundary Current)

  • 장승환;신정선;문병권
    • 한국지구과학회지
    • /
    • 제31권1호
    • /
    • pp.88-94
    • /
    • 2010
  • 서안경계류의 발생 역학을 이해하기 위하여 간단한 실험 장치와 방법을 개발하였다. 위도에 따른 코리올리 파라미터의 변화(즉 베타효과)를 구현하기 위하여 바닥이 경사진 반 시계 방향으로 회전하는 수조를 이용하였다. 중위도 해양에 작용하는 바람 응력은 수조 상부에서 시계 방향으로 회전하는 원판으로 대신하였다. 수조 바닥의 형태와 수조의 회전 유무의 조합으로 구성된 4가지 실험을 수행하였다. 그 결과, 베타효과가 포함된 실험에서 서안경계류와 유사한 흐름과 스베드럽 영역을 볼 수 있었다. 반면에, 베타효과 없이 일정한 코리올리 힘만 있을 때는 수조 속의 물은 관성류의 특징을 나타냈다. 우리는 또한 회전 유체가 굳어진 것처럼 변한다는 테일러-프라우드만 효과를 확인 하였다. 이 연구에서 개발된 장치와 방법은 베타효과에 의한 서안경계류를 이해하는 데 도움을 줄 것으로 기대한다.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.